• Title/Summary/Keyword: ELF

Search Result 199, Processing Time 0.025 seconds

Effect of Analysis Procedures on Seismic Collapse Risk of Steel Special Moment Frames (내진설계에서 사용한 해석방법이 철골 특수모멘트골조의 붕괴위험도에 미치는 영향 평가)

  • Kim, Taeo;Han, Sang Whan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.6
    • /
    • pp.243-251
    • /
    • 2020
  • In seismic design standards such as KDS 41 17 00 and ASCE 7, three procedures are provided to estimate seismic demands: equivalent lateral force (ELF), response spectrum analysis (RSA), and response history analysis (RHA). In this study, two steel special moment frames (SMFs) were designed with ELF and RSA, which have been commonly used in engineering practice. The collapse probabilities of the SMFs were evaluated according to FEMA P695 methodology. It was observed that collapse probabilities varied significantly in accordance with analysis procedures. SMFs designed with RSA (RSA-SMFs) had a higher probability of collapse than SMFs designed with ELF (ELF-SMFs). Furthermore, RSA-SMFs did not satisfy the target collapse probability specified in ASCE 7-16 whereas ELF-SMFs met the target probability.

Analysis of current density distribution and in vitro exposure system for ELF exposed cell experiments (ELF 전자파 피폭 세포실험을 위한 배양기의 전류밀도 분포해석 및 Invitro 노출장치 설계)

  • 김대근;정재승;안재목
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2000.11a
    • /
    • pp.297-301
    • /
    • 2000
  • ELF 전자파의 생물학적인 영향 평가를 위한 in vitro 세포 실험에서 노출장치의 설계는 코일내피 유도기전력(E)과 전류밀도(J) 해석과 함께 이루어져야 한다. 균일 자기장 속에서 세포를 배양할 경우애도 배양기내의 전도성 매질로 인해 균일한 E와 J가 분포하지 않는다. 따라서 균일한 ELF 자기장 노출장치로부터 발생되는 샘플 매질 내에서의 E나 J를 정확히 예측하는 것은 in vitro 세포실험의 성공여부를 가늠 할 정도로 매우 중요한 정보가 된다. 이에 본 논문에서는 in vitro 실험에 적합한 ELF in vitro 노출 장치를 설계하고 노출 장치에 대한 전자기학적 평가를 수행하였다. 코일 내에서 샘플 매질의 유무와 샘플 내에서도 세포가 놓여질 임의의 위치에 따라 E와 J를 예측하고 검증을 위한 측정과 시뮬레이션을 시도하였다. 노출장치는 헬름 홀쯔 코일로 제작되었고 자기장의 세기는 1-2OG 범위 내에서 가변이 가능하다. 또한 코일내의 자기장의 분포가 균일(uniform), 비균일(nonuniform)만 두 가지모드를 각각 제작하여 보았다.

  • PDF

Yeast Elf1 Factor Is Phosphorylated and Interacts with Protein Kinase CK2

  • Kubinski, Konrad;Zielinski, Rafal;Hellman, Ulf;Mazur, Elzbieta;Szyszka, Ryszard
    • BMB Reports
    • /
    • v.39 no.3
    • /
    • pp.311-318
    • /
    • 2006
  • One of the biggest group of proteins influenced by protein kinase CK2 is formed by factors engaged in gene expression. Here we have reported recently identified yeast transcription elongation factor Elf1 as a new substrate for both monomeric and tetrameric forms of CK2. Elf1 serves as a substrate for both the recombinant CK2$\alpha$' ($K_m$ 0.38 ${\mu}M$) and holoenzyme ($K_m$ $0.13\;{\mu}M$). By MALDI-MS we identified the two serine residues at positions 95 and 117 as the most probable in vitro phosphorylation sites. Co-immunoprecypitation experiments show that Elf1 interacts with catalytic ($\alpha$ and $\alpha$') as well as regulatory ($\beta$ and $\beta$') subunits of CK2. These data may help to elucidate the role of protein kinase CK2 and Elf1 in the regulation of transcription elongation.

Effects of 60-Hz Magnetic Fields on DNA Damage Responses in HT22 Mouse Hippocampal Cell Lines

  • Mun, Gil-Im;Lee, Seungwoo;Kim, Nam;Lee, Yun-Sil
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.123-128
    • /
    • 2015
  • Previously, we investigated extremely low-frequency magnetic fields (ELF-MFs) on diverse DNA damage responses, such as phosphorylated H2AX (${\gamma}H2AX$), comet tail moments, and aneuploidy production in several non-tumorigenic epithelial or fibroblast cell lines. However, the effect of ELF-MF on DNA damage responses in neuronal cells may not be well evaluated. Here, we investigated the effects of ELF-MF on the DNA damage responses in HT22 non-tumorigenic mouse neuronal cells. Exposure to a 60-Hz, 2 mT ELF-MF did not produce any increased ${\gamma}H2AX$ expression, comet tail moments, or aneuploidy formation. However, 2 mT ELF-MF transiently increased the cell number. From the results, ELF-MF could affect the DNA damage responses differently, depending on the cell lines.

Evaluation of Intensity of Extremely Low Frequency Magnetic Fields (ELF-MF) Inside of Cabins as Generated During Subway Operation (지하철 운행 중 발생하는 객차 내부 극저주파 자기장(ELF-MF) 세기 평가)

  • Lee, Jihyun;Kang, Myeongji;Park, Yunkyung;Park, Donguk;Choi, Sangjun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.2
    • /
    • pp.185-194
    • /
    • 2019
  • Objective: This study was conducted to investigate the intensity of the extremely low frequency magnetic fields(ELF-MF) generated inside of the cabins during subway operation. Methods: The ELF-MF intensity were investigated on 30 subway lines in Korea, including in the Greater Seoul Metropolitan Area(Seoul and Gyeonggi-do Province), Incheon, Busan, Daegu, Daejeon, and Gwangju. ELF-MF intensity was measured at 0.9 m from the floor using EMDEX II meters with a resolution of $0.01{\mu}T$. All data were collected every three seconds and analyzed with EMCALC 2013 version 3.0B software. Basic characteristics of subway operation, including alternative current(AC) or direct current(DC), voltage level, and opening year of the line were investigated. Real-time information during measurement, such as the time of departure, moving and arrival of trains, were also recorded. Results: The arithmetic mean(AM) and maximum(Max) intensity of ELF-MF were $0.62{\mu}T$ and $11.51{\mu}T$, respectively. Compared by region, the ELF-MF intensity measured inside cabin were the highest in the Seoul Metropolitan Area($AM=0.80{\mu}T$), followed by Busan($AM=0.30{\mu}T$), Daegu($AM=0.29{\mu}T$), Incheon($AM=0.14{\mu}T$), Gwangju($AM=0.04{\mu}T$) and Daejeon($AM=0.03{\mu}T$). The average ELF-MF level measured in AC trains($AM=1.36{\mu}T$) was also significantly higher than in DC trains($AM=0.28{\mu}T$). In terms of the opening year of the subway, trains opened before 1990($AM=0.85{\mu}T$) was the highest and the lowest was 2000-2009($AM=0.24{\mu}T$). Conclusions: The AC supply has the greatest influence on the generation of the ELF-MF intensity in subway cabins.

Analysis of Current Density Distribution and In Vitro Exposur System fot ELF Exposed Cell Experiments (ELF 전자파 피폭 세포실험을 위한 배양기의 전류밀도 분포 해석 및 In Vitro 노출장치 설계)

  • 김대근;정재승;안재목
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.1
    • /
    • pp.84-91
    • /
    • 2001
  • In in vitro cell experiments for the biological assessment of electromagnetic (EM) field, exposure system (ES) must be analyzed in terms of current density (J) and induced electric field intensity (E). Although in uniform B field, E and J in the sample medium are not distributed uniformly because of conductivity in sample dish. Thus, the precise estimation for E and J induced by uniform ELF within sample media is very important keys for successful in in vitro experiments. In this paper, we designed in vitro ELF ES with electromagnetic analysis using MATLAB simulator. Then we calculated from the measured B field to verify induced E & J distribution for random locations of cells within media in two cases of samples existence or not. ES with B field ranging from 0 to 20G consists of Helmholz coil and current generator based on the microprocessor. Also, we developed ELFES for each B field generation as uniform and non-uniform modes.

  • PDF

Extremely Low Frequency Magnetic Field Modulates the Level of Neurotransmitters

  • Chung, Yoon Hee;Lee, Young Joo;Lee, Ho Sung;Chung, Su Jin;Lim, Cheol Hee;Oh, Keon Woong;Sohn, Uy Dong;Park, Eon Sub;Jeong, Ji Hoon
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.19 no.1
    • /
    • pp.15-20
    • /
    • 2015
  • This study was aimed to observe that extremely low frequency magnetic field (ELF-MF) may be relevant to changes of major neurotransmitters in rat brain. After the exposure to ELF-MF (60 Hz, 2.0 mT) for 2 or 5 days, we measured the levels of biogenic amines and their metabolites, amino acid neurotransmitters and nitric oxide (NO) in the cortex, striatum, thalamus, cerebellum and hippocampus. The exposure of ELF-MF for 2 or 5 days produced significant differences in norepinephrine and vanillyl mandelic acid in the striatum, thalamus, cerebellum and hippocampus. Significant increases in the levels of serotonin and 5-hydroxyindoleacetic acid were also observed in the striatum, thalamus or hippocampus. ELF-MF significantly increased the concentration of dopamine in the thalamus. ELF-MF tended to increase the levels of amino acid neurotransmitters such as glutamine, glycine and ${\gamma}$-aminobutyric acid in the striatum and thalamus, whereas it decreased the levels in the cortex, cerebellum and hippocampus. ELF-MF significantly increased NO concentration in the striatum, thalamus and hippocampus. The present study has demonstrated that exposure to ELF-MFs may evoke the changes in the levels of biogenic amines, amino acid and NO in the brain although the extent and property vary with the brain areas. However, the mechanisms remain further to be characterized.

Discussion of Exposure Evaluation Associated with Extremely Low Frequency-magnetic Field in the Case of Portable Hand-held Fans (휴대용 손 선풍기의 극저주파 자기장 발생 수준 평가와 쟁점 고찰)

  • Park, Dong-Uk;Yi, Seongjin;Kim, So-Youn;Bae, Seo-Youn;Choi, Sangjun;Kim, Won;Min, Sung Hyon;Park, Jihoon;Ahn, Jongju
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.5
    • /
    • pp.480-490
    • /
    • 2018
  • Objective: This study aimed to report the level of extremely low frequency-magnetic field (ELF-MF) emitted by portable hand-held fans (HHF) and to discuss the methodologies for determining the health risk of ELF-MF for HHF products. Method: ELF-MF was monitored at eight locations by distances in the vicinity of HHFs. A total of 13 HHF brands on the market were randomly selected. A portable ELF-MF monitor MDEX II was used to measure the ELF-MF level in the range of 40-800 Hz with a resolution of $0.01{\mu}T$. This study also examined the frequency results of a total of 45 HHF products investigated by the Korean Ministry of Science and ICT (KMSICT). Results: ELF-MF higher than $0.3{\mu}T$ was found to be emitted at a distance of less than 20 cm from 12 HHF. ELF-MF emitted from four products was found to exceed the reference level ($83.3{\mu}T$ based on 60 Hz) recommended by the International Commission on Non-Ionizing Radiation Protection (ICNIRP). KMSIT reported that the principle frequency emitted from the HHFs ranged from 54 Hz to 284 kHz, without the level of LEF-MF. Unscientifically, the KMSICT used the reference level by ICNIRP as the chronic level and concluded that all HHFs are safe with a basis of 1.2-36.0% less than the reference level. Conclusion: The HHF emitted much higher levels of ELF-MF than $0.3-0.4{\mu}T$, which is regarded as the reference level for childhood leukemia. The risk of HHF should be examined in terms of whether they can be used by the general public, including children and pregnant woman.

ELF 전자계의 인체 유해성

  • 김석주
    • 전기의세계
    • /
    • v.41 no.7
    • /
    • pp.4-12
    • /
    • 1992
  • ELF 전계 및 자계의 인체 유해성 문제는 서로 상반된 결과가 도출된 경우가 많기때문에 아직 이렇다할 결론을 내리기가 어려운 상태이다. 그것은 첫째 인체영향을 나타내는 메카니즘이 상당히 복잡하고 둘째 전자계 노출과 그 영향과의 관계가 노출량과 같은 한개만의 매개 변수에 의해서 결정되는 것이 아니고 여러가지의 매개 변수에 의해서 좌우되기 때문이라고 할 수 있다. 혹자는 ELF 전자계가 인체에 유해하다고 할지라도 우리가 처해있는 일상 생활에서의 다른 위험보다는 적을 것이라고 주장하지만 전자계는 도처에 존재하므로 미소한 영향이라 하더라도 국민보건차원에서는 심각할 수도 있다. 따라서 이 분야의 연구는 WHO를 비롯해서 모든 나라가 더 많은 연구를 해야 한다고 하고 있다.

  • PDF

THE EFFECT OF EXTREMELY LOW FREQUENCY MAGNETIC FIELD (ELF-MF) ON THE FREQUENCY OF MICRONUCLEI IN HUMAN LYMPHOCYTES INDUCED BY BENZO(A)PYRENE

  • Cho, Yoon-Hee;Kim, Su-Young;Chung, Hai-Won
    • Proceedings of the Korean Society of Toxicology Conference
    • /
    • 2001.10a
    • /
    • pp.178-178
    • /
    • 2001
  • The interaction of extremely low frequency magnetic field (ELF-MF) on the frequency of micronuclei (MN) induced by benzo(a)pyrene (BP) in human lymphocytes was examined. A 60 Hz ELF-MF of 0.8 mT field strength was applied for 24 hours either alone or with the tumour initiator, BP. The frequency of MN induced by BP increased in a dose-dependent manner.(omitted)

  • PDF