• 제목/요약/키워드: EES(Engineering Equation Solver)

검색결과 8건 처리시간 0.02초

태양열 외기 난방 시스템의 열성능 시뮬레이션 및 검증 연구 (Solar Air Heating System Thermal Performance Simulation and Verification)

  • 강동언;이의준;현명택
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.152-157
    • /
    • 2001
  • UTC(Unglazed Transpired Collector) system has recently emerged as a new solar air heating technology. It is relatively inexpensive because it has not a glazed material. And it demonstrates efficient particularly for the applications in which larger wall area facilities with a high outdoor air requirement. Mathematical algorithm for UTC thermal modeling has been understood for further improvement of the system. EES and TRNSYS model of actual solar wall panel could be developed for computer simulations under other conditions. Computer models could be validated with the measured data from fixed outdoor test cell in KIER(Korea Institute of Energy Research). Major design parameters could be identified such as panel configuration and absorptivity and emissivity values for UTC design.

  • PDF

온수제조용 CO2 히트펌프의 가스쿨러 열전달 성능 해석 (Analysis of Heat Transfer Performance of a Gas Cooler of CO2 Heat Pump for Water Heating)

  • 권정태;이창경;백동석;권영철
    • 한국산학기술학회논문지
    • /
    • 제14권11호
    • /
    • pp.5317-5322
    • /
    • 2013
  • 본 연구에서는 ${\epsilon}$-NTU 방법을 사용하여 $CO_2$ 히트펌프 가스쿨러의 열전달 성능을 해석하였고, 공개된 실험결과와 비교하였다. $CO_2$ 히트펌프 가스쿨러의 열전달률, 냉매측/순환수측 출구온도를 EES로 계산하였다. 해석은 시험부를 하나의 구간으로 설정하여 냉매와 순환수측 입출구의 평균온도를 물성치로 적용한 평균해석과 시험부를 50구간으로 나누어 각 구간에서의 출구온도를 다음 구간의 입구온도로 사용한 국소해석으로 진행되었다. 실험결과로부터 평균해석보다는 국소해석의 결과가 실험값을 더 만족하였으며, 열전달률은 0.3~1.1%, 순환수측 출구온도는 1.31~1.88%, 냉매측 출구온도는 3.12~5.18% 정도의 오차를 보였다.

Exergetic design and analysis of a nuclear SMR reactor tetrageneration (combined water, heat, power, and chemicals) with designed PCM energy storage and a CO2 gas turbine inner cycle

  • Norouzi, Nima;Fani, Maryam;Talebi, Saeed
    • Nuclear Engineering and Technology
    • /
    • 제53권2호
    • /
    • pp.677-687
    • /
    • 2021
  • The tendency to renewables is one of the consequences of changing attitudes towards energy issues. As a result, solar energy, which is the leader among renewable energies based on availability and potential, plays a crucial role in full filing global needs. Significant problems with the solar thermal power plants (STPP) are the operation time, which is limited by daylight and is approximately half of the power plants with fossil fuels, and the capital cost. Exergy analysis survey of STPP hybrid with PCM storage carried out using Engineering Equation Solver (EES) program with genetic algorithm (GA) for three different scenarios, based on eight decision variables, which led us to decrease final product cost (electricity) in optimized scenario up to 30% compare to base case scenario from 28.99 $/kWh to 20.27 $/kWh for the case study. Also, in the optimal third scenario of this plant, the inner carbon dioxide gas cycle produces 1200 kW power with a thermal efficiency of 59% and also 1000 m3/h water with an exergy efficiency of 23.4% and 79.70 kg/h with an overall exergy efficiency of 34% is produced in the tetrageneration plant.

Simulation of $H_2O/LiBr$ Triple Effect Absorption Systems with a Modified Reverse Flow

  • Jo, Young-Kyong;Kim, Jin-Kyeong;Kang, Yang-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권3호
    • /
    • pp.114-121
    • /
    • 2007
  • In this study, a modified reverse flow type, one of the triple effect absorption cycles, is studied for performance improvement. The cycle simulation is carried out by using EES(Engineering Equation Solver) program for the working fluid of $H_2O/LiBr$ solution. The split-ratios of solution flow rate, UA of each component, pumping mass flow rate of solution are considered as key parameters. The results show that the optimal SRH (split ratio of high side) and SRL (split ratio of low side) values are 0.596 and 0.521, respectively. Under these conditions, the COP is maximized to 2.1. The optimal pumping mass flow rate is selected as 3 kg/s and the corresponding UAEV A is 121 kW/K in the present system. The present simulation results are compared to the other literature results from Kaita's (2002) and Cho's (1998) triple effect absorption systems. The present system has a lower solution temperature and a higher COP than the Kaita's modified reverse flow, and it also gives a higher COP than the Cho's parallel flow by adjusting split ratios.

폐열이용 열펌프시스템의 성능에 관한 연구 (Performance Analysis on a Heat Pump System using Waste Heat)

  • 박윤철;송뢰;고광수
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권4호
    • /
    • pp.53-60
    • /
    • 2018
  • This study was conducted for analysis of a heat pump system using waste heat in an enclosed space such as a green house. The model was developed with mathematical equations in literature and Engineering Equation Solver (EES) was used to get the solution of the developed equations. The simulation results have 5% of reliability comparing the results with actual test data of heat pump system's dynamic operation. The operating performance of the system was calculated with variation of working fluid temperature in the thermal storage tank such as $25^{\circ}C$, $35^{\circ}C$, $45^{\circ}C$ and $55^{\circ}C$. As a result, the system's the highest total heating capacity shows 280 kWh and the storage tank's operating time decreased as the starting storage tank's temperature was high.

해양온도차 발전을 위한 심층수 파이프 직경에 따른 에너지 손실량 검토 (Feasibility Study on Cold Water Pipe Diameter by Friction Loss and Energy Conversion on OTEC)

  • 정훈;허균영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.170-170
    • /
    • 2010
  • The energy conversion from the temperature difference between hot and cold source like ocean thermal energy conversion (OTEC), requires a long and large-diameter pipe (about 1000 to 10,000 meters long) to reach the deep water. The pipe diameter ranges from 2.8 meter for proposed early test systems, to 5 meter for large, commercial power generation systems. The pipe must be designed to resist collapsing pressures produced by water temperature and density differences, and the reduced pressure required to induce flow up the pipe. Other design considerations include the external-drag effect on the pipe due to ocean currents, and the wave-induced motions of the platform to which the pipe is attached. Various approaches to the pipe construction have been proposed, including aluminum, steel, concrete, and fiberglass. More recently, a flexible pipe construction involving the use of fiberglass reinforced plastic has been proposed. This report presents the results of a scaled fixed cold water pipe (CWP) model test program performed by EES(Engineering Equation Solver) to demonstrate the feasibility of this pipe approach.

  • PDF

2단 압축 하이브리드 히트펌프의 특성 시뮬레이션 (Numerical Simulation of a Two-Stage Hybrid Heat Pump)

  • 정시영;윤한구;박기웅;박성룡;김민성
    • 대한기계학회논문집B
    • /
    • 제34권2호
    • /
    • pp.191-196
    • /
    • 2010
  • 기존의 증기압축식과 흡수식을 결합한 하이브리드 히트펌프는 $50^{\circ}C$정도의 저열원에서 $80{\sim}90^{\circ}C$의 온수를 효과적으로 생산할 수 있다. 본 연구에서는 EES를 사용하여 2단 압축 하이브리드 히트펌프와 1단 압축 하이브리드 히트펌프의 성능을 비교하였다. 동일한 작동조건에서 2단 압축 하이브리드 히트펌프는 1단 압축 하이브리드 히트펌프보다 약간 높은 COP를 가지며 더 안정적인 상태에서 운전이 가능한 것으로 나타났다. 2단 압축 하이브리드 히트펌프에서 작동 유체의 최대 온도는 1단 압축 하이브리드 히트펌프보다 40K정도 낮게 나타났으며 이는 윤활유의 작동에 무리없는 운전상태를 가능하게 한다. 1단과 2단 하이브리드 히트펌프 모두 UA값이 증가할 때 COP는 감소하였으며 열출력은 증가하였다.

곡물냉각기의 성능해석을 위한 시뮬레이션 (Simulation for Performance Analysis of a Grain Cooler)

  • 박진호;정종훈
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.449-460
    • /
    • 2001
  • This study was carried out to develop a simulation model with EES(Engineering equation solver) for analyzing the performance of a grain cooler. In order to validate the developed simulation model, several main factors which have affected on the performance of the gain cooler were investigated through experiments. A simulation model was developed in the standard vapor compression cycle, and then this model was modified considering irreversibe factors so that the developed alternate model could predict the actual cycle of a grain cooler. The compressor efficiency in vapor compression cycle considering irreversibility much affected on the coefficient of performance(COP). The COP in the standard vapor compression cycle model was greatly as high as about 6.50, but the COP in an alternative model considering irreversibility was as low as about 3.27. As a result of comparison between the actual cycle and the vapor compression cycle considering irreversibility, the difference of pressure at compressor outlet(inlet) was a little by about 48kPa (8.8kPa), the temperatures of refrigerant at main parts of the grain cooler were similar. and the temperature of chilled air was about 8$\^{C}$ in both. The model considering irreversibility could predict performance of the grain cooler. The theoretical period required to chill grain of 1,383kg from the initial temperature 24$\^{C}$ to below 11$\^{C}$ was about 55 hours 30 minutes, and the actual period required in a grain bin was about 58 hours. The difference between the predicted and an actual period was about 2 hours 30 minutes. The cooling performance predicted by the developed model could well estimate the cooling period required to chill the grain.

  • PDF