• Title/Summary/Keyword: EEG index

Search Result 119, Processing Time 0.024 seconds

Development of the Game for Increasing Intensive Power using EEG Signal (뇌파신호를 이용한 집중력 향상 게임 구현)

  • Lee, Chang-Jo
    • Journal of Korea Game Society
    • /
    • v.9 no.2
    • /
    • pp.23-28
    • /
    • 2009
  • There are a lot of games which have good benefits in the game genre such as serious game. In this paper we implement an serious game for increasing intensive power by calculating the index of the intensive power based on EEG signal. First we explain the definition of the EEG and the classification of the brainwaves and we depict the method for increasing the intensive power. Then we apply the index of the intensive power to the game production to train the intensive power. At last we make an experiment on the effect of an game which increases the intensive power and the analysis shows the increase of the intensive power.

  • PDF

Development for the Evaluation Index of an Anesthesia Depth using the Bispectrum Analysis (Bispectrum 분석을 이용한 마취 심도 평가 지표 개발)

  • Park, Jun-Mo;Ye, Soo-Young;Nam, Ki-Gon;Jeon, Gye-Rok
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.750-755
    • /
    • 2007
  • The linear SEF (Spectral Edge Frequency) parameter and spectrum analysis method can not reflect the non-linear of EEG. This method can not contribute to acquire real time analysis and obtain a high confidence in the clinic due to low discrimination. To solve the problems, the development of a new index is carried out using the bispectrum analyzing the EEG including the non-linear characteristic. At the bispectrum analysis of the 2 dimension, the most significant's power spectrum density peaks appeared much at the specific area in awake and anesthesia state. Because many peaks are showed at the specific area in the frequency coordinate, these points are used to create the new index. Range of the index is 0-100. At the anesthesia, the index is 20-50 and at the awake, the index is 90-60. New index can discriminate the awake and anesthesia state.

A Study on EEG based Concentration Transmission and Brain Computer Interface Application (뇌파기반 집중도 전송 및 BCI 적용에 관한 연구)

  • Lee, Chung-Heon;Kwon, Jang-Woo;Kim, Gyu-Dong;Hong, Jun-Eui;Shin, Dae-Seob;Lee, Dong-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.41-46
    • /
    • 2009
  • This research measures EEG signals which are generating on head skin and extracts brain concentration level related with brain activity. We develop concentration wireless transmission system for controlling hardware by using this signal. Two channels are used for measuring EEG signal on front head and Biopac system with MP100 and EEG100C was used for measuring EEG signal, amplifying and filtering the signal. LabView 8.5 was also used for FFT transformation, frequency and spectrum analysis of the measured EEG signals. As a result, SMR wave, Mid-Bata wave, $\Theta$ wave classified. We extracted the concentration index by adapting concentration extraction algorithm. This concentration uldex was transferred into logo automobile device by wireless module and applied for BCI application.

Relation between heart rate variability and spectral analysis of electroencephalogram in chronic neuropathic pain patients

  • John Rajan;Girwar Singh Gaur;Karthik Shanmugavel;Adinarayanan S
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.28 no.3
    • /
    • pp.253-264
    • /
    • 2024
  • Chronic neuropathic pain (CNP) is a complex condition often arising from neural maladaptation after nerve injury. Understanding CNP complications involves the intricate interplay between brain-heart dynamics, assessed through quantitative electroencephalogram (qEEG) and heart rate variability (HRV). However, insights into their interaction in chronic pain are limited. Resting EEG and simultaneous electrocardiogram (lead II) of the participants were recorded for qEEG and HRV analysis. Correlations between HRV and qEEG parameters were calculated and compared with age, sex, and body mass index (BMI)-matched controls. CNP patients showed reduced HRV and significant increases in qEEG power spectral densities within delta, theta, and beta frequency ranges. A positive correlation was found between low frequency/high frequency (LF/HF) ratio in HRV analysis and theta, alpha, and beta frequency bands in qEEG among CNP patients. However, no significant correlation was observed between parasympathetic indices and theta, beta bands in qEEG within CNP group, unlike age, sex, and BMI-matched healthy controls. CNP patients display significant HRV reductions and distinctive qEEG patterns. While healthy controls exhibit significant correlations between parasympathetic HRV parameters and qEEG spectral densities, these relationships are diminished or absent in CNP individuals. LF/HF ratio, reflecting sympathovagal balance, correlates significantly with qEEG frequency bands (theta, alpha, beta), illuminating autonomic dysregulation in CNP. These findings emphasize the intricate brain-heart interplay in chronic pain, warranting further exploration.

Correlation Between Subjective Preference of Essential Oils and EEG Response (주관적 향의 선호도와 뇌파 반응과의 상관관계)

  • 민병찬;정순철;한정수;변증남;김철중;김준수
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.38-43
    • /
    • 2000
  • In this present study, the correlation between subjective preference of essential odors and EEG response were investigated quantitatively. EEG signals were measured from 19 electrodes according to the International 10-20 system (Fpl, Fp2, F2/4, F7/8, Fz, C3/4, Cz, P3/4, Pz, T3/4, T5/6, Ol/2) from 8 healthy males subjects in four odor conditions. Four odor conditions (Rose oil bulgarian, Lemon oil misitano, Jasmin abs, Laverder iol france (KIMEX co. Ltd)) were applied for each subject in the experiment. Through the subjective evaluation, the most pleasant odor for each subject was determined. The power spectrum of ${\alpha}$/${\beta}$ of EEG signals from the most pleasant odor was compared with those from the control condition, which has no odor at all. It was observed that the power spectrum of ${\alpha}$/${\beta}$ of EEG from the most pleasant odor was increased significantly on F3, F3, F4,74 comparing to the control condition. This result indicates that the power spectrum of ai${\beta}$ could be a new index for measuring the levels of pleasantness of odors.

  • PDF

A Study on Correlation Between Subjective Assessment and EEG for Essential Odors (주관적 향의 선호도와 뇌파 반응과의 상관관계)

  • Min, Byeong-Chan;Han, Jeong-Su;Jeong, Sun-Cheol;Byeon, Jeung-Nam;Kim, Ji-Gwan;Kim, Cheol-Jung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.20 no.3
    • /
    • pp.1-9
    • /
    • 2001
  • In the present study, the correlation between subjective assessment and EEG for essential odors were investigated quantitatively. EEG signals were measured from 19 electrodes according to the International 10-20 system (Fp1, Fp2, F3/4, F7/8, Fz, C3/4, Cz, P3/4, Pz, T3/4, T5/6, O1/2) from 8 healthy males subjects for four odor(Rose oil bulgarian, Lemon oil misitano, jasmin abs, Laverder oil france (KIMEX co. Ltd) conditions. The result of the subjective assessment shows the most pleasant odor for each subject. and the power spectrum of ${\alpha}/({\alpha}+{\beta})$ of EEG signals from the most pleasant odor was compared with those from the control condition, which has no odor at all. Power spectrum of ${\alpha}/({\alpha}+{\beta})$ of EEG from the most pleasant odor was increased significantly at T4, T6 compared to the control condition. This result implies that the parameter, power spectrum of ${\alpha}/({\alpha}+{\beta})$, could be an important index for signifying the levels of pleasantness for odors.

  • PDF

Analysis of EEG Signal Differences in Gender according to Textile Attachments (섬유 애착물의 종류에 따른 남녀 뇌파 신호 차이 분석)

  • Lee, Okkyung;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.5
    • /
    • pp.824-836
    • /
    • 2020
  • This study investigated the effects of textile attachments on electroencephalogram using 20 persons (10 males and 10 females). Four types of attachment cushions were manufactured by changing the shell fabric (cotton and microfiber) and interlining (synthetic loose fiber and buckwheat). This was done using BIOS-S8 (BioBrain Inc., Korea), an 8-channel polygraph for multi-body signal measurement, to measure EEG. Data were analyzed using the SPSS 24.0 statistical program. EEG values were significantly activated according to gender, particularly when the subjects' eyes were open. For the male cases, 'RT', 'RAHB' values were highly activated and for the female cases, 'RA', 'RB', 'RG', 'RFA', 'RST', 'RLB', 'RMB', 'RST', 'RMT' values were highly activated. Examining the differences in EEG according to type of attachment indicated no significant difference in both sexes. However, in cases of females with their eyes closed, the 'RSA' index was quite different in the left occipital lobe (O1), and when their eyes were open, the 'RFA' in the right frontal lobe (F4) showed a significant difference. However, there was no obvious correlation between the activation of EEG and the subjective preference of textile attachments.

New index for the gifted students(G-Index) with EEG analysis (뇌파검사 자료를 기반으로 한 과학영재 판별 지수(G-Index) 개발과 적용)

  • Kim, Kyung-Hwa;Kim, Kyu-Han;Lee, Sun-Kil;Hur, Myung;Kim, Yong-Jin
    • Journal of Gifted/Talented Education
    • /
    • v.15 no.1
    • /
    • pp.67-84
    • /
    • 2005
  • In this study we investigated the adequacy of tools for distinction gifted students through the comparison these mutual relation on the basis of data, like paper test, the depths interview score, and the rest data((TTCT: Torrance Tests of Creative Thinking, IQ test, FASP: Find A Shape Puzzle, V.T: Visualization Tests and Exp: experimental ability test), and analysis data of EEG test for examining the adequacy of tools for identification gifted students. So, we developed Brain Wave gifted Index(G-Index) for finding another distinction ability as using brain waves data. The standard of index development use gifted brain characteristic in closed-eyes rest state which is judged like that characteristic of distinction between gifted and normal students is the most clear and consistence. That is, the degree of unified pattern between each object and gifted PCA pattern was defined by Pearson method which added spatial mutual index to weight concept. This refer to mean number of spatial PCA pattern. Searching for the possibility of distinction gifted gave distinction effect in 76%. The result of regression analysis on the basis of mutual relation between the rest data is . The probability formula for distinct gifted group is as follow. $$P=\frac 1{1+e^{-[-0.018(TTCT)+0.057(IQ)+1.916(FASP)+0.682(V.T)+0.088(Exp.)+0.034(G-Index)-57.510]}}$$ The result of this calculation showed that probability for distinct in gifted group was very good(95.0%). On the basis of upper result, tools for identification gifted students should be estimated as using many-sided estimation data whatever possible. And following study about development, and operation of tools for distinction suitable to gifted student in science should be progressed.

Comparison of Psychological and Physiological Differences of Human due to the EEG Type Scent (뇌파유형별 향기에 따른 인체의 심리적 및 생리적 차이 비교)

  • Kim, Myung Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.1
    • /
    • pp.418-425
    • /
    • 2013
  • In this study, the three scents effects on subjects due to EEG type, and it researched to find optimal scent to increase their amenity and productivity. EEG and HRV were compared and analyzed in the environmental test room by classifying subjects into two type: A and B. The condition of the environmental test room was in temperature 31[$^{\circ}C$], relative humidity 50[RH%], air current speed 0.02[m/s] and illuminance 1000[lux] with setting up three different scents which are Rosemary, Jasmine and Hazelnut. The result of this study, at Jasmine scent for A and B type, relative ${\alpha}$ wave, SEF50, $\frac{SMR}{\theta}$ and SDNN were revitalized, and ${\alpha}$ wave asymmetry index, HRT, stress index and fatigue degree were decreased. It was found that favorite scent of A and B type is same as Jasmine scent, but A type was more sensitive than B type about scent. Therefore Jasmine scent is very effective to increase amenity, productivity and concentration, and to decrease stress and fatigue degree.

Performance Evaluation of EEG-BCI Interface Algorithm in BCI(Brain Computer Interface)-Naive Subjects (뇌컴퓨터접속(BCI) 무경험자에 대한 EEG-BCI 알고리즘 성능평가)

  • Kim, Jin-Kwon;Kang, Dae-Hun;Lee, Young-Bum;Jung, Hee-Gyo;Lee, In-Su;Park, Hae-Dae;Kim, Eun-Ju;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.5
    • /
    • pp.428-437
    • /
    • 2009
  • The Performance research about EEG-BCI algorithm in BCI-naive subjects is very important for evaluating the applicability to the public. We analyzed the result of the performance evaluation experiment about the EEG-BCI algorithm in BCI-naive subjects on three different aspects. The EEG-BCI algorithm used in this paper is composed of the common spatial pattern(CSP) and the least square linear classifier. CSP is used for obtaining the characteristic of event related desynchronization, and the least square linear classifier classifies the motor imagery EEG data of the left hand or right hand. The performance evaluation experiments about EEG-BCI algorithm is conducted for 40 men and women whose age are 23.87${\pm}$2.47. The performance evaluation about EEG-BCI algorithm in BCI-naive subjects is analyzed in terms of the accuracy, the relation between the information transfer rate and the accuracy, and the performance changes when the different types of cue were used in the training session and testing session. On the result of experiment, BCI-naive group has about 20% subjects whose accuracy exceed 0.7. And this results of the accuracy were not effected significantly by the types of cue. The Information transfer rate is in the inverse proportion to the accuracy. And the accuracy shows the severe deterioration when the motor imagery is less then 2 seconds.