• Title/Summary/Keyword: ECOTECT

Search Result 30, Processing Time 0.025 seconds

Correlation Analysis between Space Integration and Natural Light in K Senior Hospitals (K 노인전문병원의 공간 통합도와 자연광의 상관관계 분석)

  • Moon, Sun-Young;Lee, Hyun-Soo
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.2
    • /
    • pp.189-196
    • /
    • 2015
  • In case of Senior Hospitals, meticulous care is required in both amount and quality of natural lighting because of the semi-long term residence of patients. Natural lighting has a huge impact on the physical and psychological part for the seniors. Likewise, natural lighting is an important factor considered for hospital design because it can also effect hospitalization period of patients. Research subject was K Senior Hospital which was determined as the courtyard-type building made to provide healing environment through natural lighting. Analysis was performed by dividing the space of K Senior Hospital into Central Treatment Department directly used by patients, Outpatient Department(OPD), Ward Department, Common Use Department. Research was carried out in two ways of integration value analysis using SPACE SYNTAX and illumination intensity analysis using ECOTECT. K Senior Hospital intended to actively let in natural light through courtyard and to make patients exposed to natural light when they walk along the circuit corridor built around the courtyard. This environmental consideration affected the utilization rate of Common Use Department and residence time of patients raising the average of Common Use Department on every floor. As a resuit of this study presenting type C and type D, part of four types of illumination intensity, takes higher percentage of almost every spaces compare to the others therefore K Senior Hospital was designed on the assumption of healing environment composition through natural light. The result of this research would be used meaningfully in the space programming phase of Senior Hospitals in the future. Utilization rate can be adjusted using illumination intensity value in the space that integration rate should be planed to be high. The use(purpose) of space and integration rate can be used as a guideline to set illumination intensity of natural.

An Analysis of Permanantly Shaded Areas and the Defect Rate of Landscape Trees in Apartment Complexes Using Daylight Simulations

  • Park, Sang Wook
    • Journal of People, Plants, and Environment
    • /
    • v.23 no.3
    • /
    • pp.333-345
    • /
    • 2020
  • Background and objective: The purpose of this study was to provide basic data on trees that can be used for planting design and construction for permanently shaded areas by grasping the growth status of trees according to the daylight conditions of the outdoor spaces of apartment complexes. Methods: On the recently completed apartment complexes, daylight conditions were analyzed by using daylight simulations utilizing Solar Access Analysis of Ecotect Analysis. With a criteria for assessment of tree condition, the defect rate of trees planted in permanently shaded areas and green spaces with good daylight conditions was analyzed to suggest trees applicable to permanently shaded areas. The first tree survey was conducted from November 18, 2019 to February 15, 2020, focusing on trees planted in permanently shaded areas, and the second tree survey of all the trees planted on the study sites including permanently shaded areas was conducted from March 16 to March 30, 2020. Results: Evergreen trees which are classified as shade intolerant trees including Pinus densiflora, Thuja occidentalis, and Abies holophylla showed a higher defect rate of trees among the trees planted in permanently shaded areas. Taxus cuspidata, Zelkova serrata, Cornus kousa, Chionanthus retusus and Acer palmatum which are classified as shade tolerant trees and shade moderate tolerance trees seemed to be able to be used in the plant design of permanently shaded areas in apartment complexes because the trees showed good growth and a low tree defect rate. In addition, although it was excluded from the analysis due to a small number of samples, Sorbus commixta and Prunus cerasifera var. atropurpurea also can be used for planting in permanently shaded areas. Conclusion: The daylight simulation technique used to analyze permanent shaded areas in this study can be used as an analysis tool considering the daylight environment at the stages of design and construction, and additional research will be required to analyze tree growth according to daylight conditions through data accumulation and monitoring by managing records throughout the entire life cycle of trees in the process of planting and maintenance.

Window-to-Wall-Ratio for Energy Reduction in Early Design Stage of Residential Building

  • Lee, Myung Sik
    • Architectural research
    • /
    • v.19 no.4
    • /
    • pp.89-94
    • /
    • 2017
  • In Korea, it is necessary to improve the performance of buildings with respect to the energy efficiency while improving the quality of occupants' lives through a sustainable built environment. During the design and development process, building projects must have a comprehensive, integrated perspective that seeks to reduce heating, cooling and lighting loads through climate-responsive designs. The aim of this study is to assess the optimal window-to-wall ratio of multi-rise residential units in the early design phase in Korea. The study analyzed the variation of annual heating and cooling energy load in two apartment prototype units located in Seoul city using different WWRs. The analysis was conducted using Autodesk Ecotect Analysis 2011 tool. The study found for total annual building load reductions WWR on the south and north face should be studied independently based on the room function. It also found reducing the WWR for bedrooms and windows on the northern façade resulted in reduced total annual building load.

Energy Efficiency Prediction Based on an Evolutionary Design of Incremental Granular Model (점증적 입자 모델의 진화론적 설계에 근거한 에너지효율 예측)

  • Yeom, Chan-Uk;Kwak, Keun-Chang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.47-51
    • /
    • 2018
  • This paper is concerned with an optimization design of Incremental Granular Model(IGM) based Genetic Algorithm (GA) as an evolutionary approach. The performance of IGM has been successfully demonstrated to various examples. However, the problem of IGM is that the same number of cluster in each context is determined. Also, fuzzification factor is set as typical value. In order to solve these problems, we develop a design method for optimizing the IGM to optimize the number of cluster centers in each context and the fuzzification factor. We perform energy analysis using 12 different building shapes simulated in Ecotect. The experimental results on energy efficiency data set of building revealed that the proposed GA-based IGM showed good performance in comparison with LR and IGM.

Implementation and the Energy Efficiency of the Kinetic Shading System (가동형 차양 시스템의 구성과 에너지 효율)

  • Han, Seung-Hoon
    • KIEAE Journal
    • /
    • v.14 no.5
    • /
    • pp.67-73
    • /
    • 2014
  • This study aims at examining kinetic efficient shading systems and their implementation methods. These days, the importance of the shading devices are getting more significant due to the energy problem. Cordially, suitable shade designs are required as an important element for the exterior envelope of the building. This study employs the optimal shading design as an efficient shading method with the kinetic system that can be converted actively by the altitude of the sun. The proposed kinetic shading system works not only as a lightshelf in case the altitude of the sun is high but also as a vertical louver when the sun is getting lower in order to block the direct sunlight. This study has analyzed the thermal performance and shading coefficient of the kinetic shading system in comparison to existing fixed shading devices using the Ecotect. The results, in sum, conclude that the suggested kinetic shading system could decrease direct sunlights 26.2% more than the existing shading methods.

The optimal window system of office buildings considering energy efficiency (에너지 효율로 본 상업용 건물의 적정 창호에 관한 연구)

  • Yoo, Ho-Chun;Oh, Young-Ho;Park, Seung-Kil
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.53-60
    • /
    • 2005
  • The purpose of this study is to improve energy efficiency of windows in office buildings through the evaluation of their heating, cooling and illumination load. Energy efficiency is influenced by window size which is determined at the early stage of building design. The process of this study is as follows. First, energy performance is analysed according to the various rates of windows through computer simulation (ECOTECT). Then, the annual heating, cooling and illuminating loads according to the different window sizes are compared one another. Results indicated that the optimal window size considering energy efficiency is 50% of the surface area. When the window size is 50% of the surface area, annual maintenance expense is also smallest. Since the cost of cooling is larger than that of heating, too low indoor air temperature in summer is unfavorable based on the reasonable annual maintenance expenses.

An Optimization Design of Incremental Granular Model and Its Application (점증적 입자 모델의 최적화 설계와 응용)

  • Yeom, Chan-Uk;Kwak, Keun-Chang
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2018.05a
    • /
    • pp.442-444
    • /
    • 2018
  • 본 논문에서는 GA(Genetic Algorithm) 기반 점증적 입자모델(IGM: Incremental Granular Model)의 최적화 설계를 제안한다. IGM의 성능은 다양한 실세계 응용예제를 통해 성공적으로 연구되어져왔다. 그러나, IGM의 문제로 각 컨텍스트에서 동일한 클러스터 수가 사용되는 점과 전형적인 퍼지화 계수가 설정된다는 점이 있다. 이러한 문제를 해결하기 위해 IGM을 최적화하여 각 컨텍스트에서 클러스터 중심의 수와 퍼지화 계수를 최적화하는 설계 방법을 제시했다. 제안된 방법의 타당성을 확인하기 위해 Ecotect에서 시뮬레이션 한 12가지 건물 형태를 사용하여 에너지 효율 예측에 대한 실험을 수행하였고, 제안된 방법은 기존의 IGM보다 우수한 성능을 보이는 것을 확인했다.

Computer Simulation of Lower Farmland by the Composition of an Agrophotovoltaic System (영농형 태양광 발전 시스템 구성에 따른 하부 농지 일사량의 전산모사 연구)

  • Kim, DeokSung;Kim, ChangHeon;Park, JongSung;Kim, ChangHan;Nam, JaeWoo;Cho, JaiYoung;Lim, CheolHyun
    • New & Renewable Energy
    • /
    • v.16 no.1
    • /
    • pp.41-46
    • /
    • 2020
  • The share of agrophotovoltaics in the "renewable energy 3020", which is the Korean government policy for revitalizing new and renewable energy, is increasing gradually. In this study, the distribution of solar radiation received by crops growing on virtual farmland under a range of conditions, such as module height, module angle, shading ratio, and module type, was quantified and analyzed using an Ecotect program, which allows insolation analysis during the period from spring to fall. As the module angle increases, transmissive modules increase the amount of solar radiation delivered to the lower farmland. In addition, the difference between 3x12 Cell Type and 4x9 Cells Type, which are types of photovoltaic modules used in practice, was found to be small. The analysis results can be used as a design standard for the future establishment of agrophotovoltaic systems.

Energy Sustainability of an Integrative Kinetic Light Shelf Unit

  • Han, Seung-Hoon
    • KIEAE Journal
    • /
    • v.15 no.3
    • /
    • pp.15-20
    • /
    • 2015
  • Purpose: Suggesting a working prototype of a kinetic light shelf unit and revealing its energy efficiency by a series of building performance simulations were presented. Recently, kinetic building envelope has been an emerging technology as an innovative way to control exterior building environment, but products from many researches about the facade could not been reached to the industrialization so far. That is because its initial installation, operation and maintenance costs are still too high to use for the practical field, although buildings using kinetic envelopes could decrease their energy consumption significantly. This narrow point of view needs to be reconsidered, since buildings require great amount of energies to run their functions through the whole life and using better building components can lead to achieve much more benefits in aspects of the lifecycle cost (LCC). Method: A series of certified simulation tools like Ecotect and Green Building Studio that are normally used for researches and developments in the field of architecture were utilized. Result: Based on simulation analyses, the result of the study has showed that the proposed system definitely has adaptability to the professions and positively shows practicability as advanced integrative building envelopes with renewable energy association.

A Study on the Effect of inflow Daylight according to the installation method of controlling Light Shelf and Blind in the Room of General Hospital (종합병원 병실 내 광선반과 블라인드 설치 방식에 따른 자연채광 유입 효과 연구)

  • Cho, Ju Young;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.13 no.4
    • /
    • pp.3-10
    • /
    • 2013
  • This study aims to identify convenient surrounding of the hospital room to be improved by specifically focusing on light environment and to examine a change of inflow of the daylight in the hospital room by using blind and light shelf device as base data of preliminary research for comprehending the relationship between healing environment and natural day light. Simulation analysis on previous facilities and the installation of horizontal light shelf that derives the inflow of day light has been specifically referred by using ECOTECT2011 program. In case of C-facility that mostly adjoined to exterior spaces, it was shown to be closer to a proper uniformity factor when an angle was controlled on the light shelf with blind installed at the same time. However, it was not overall appropriate because of visual displeasure occurred from inflow of much day light. In conclusion, it is the form of flat surface such as H-facility that provides an effect after installing the device to derive day light. Especially, it was shown that interior day light environment was improved when installing blind and controlling the angle at the same time.