• 제목/요약/키워드: ECOTECT

검색결과 30건 처리시간 0.016초

ECOTECT 시뮬레이션을 활용한 학교건축의 창호계획에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로- (A Study on the Window Planning of School Building Using ECOTECT Simulation -By Dynamic Daylight Simulation Using Weather Data-)

  • 최우람;한석종;윤영일
    • KIEAE Journal
    • /
    • 제13권6호
    • /
    • pp.77-82
    • /
    • 2013
  • Light environment in the school building is one of the most important elements of the plan in order to improve student's ability to learn and the healthy growth. Thus, the window plan of the school building is a great addition to improve environmental-friendly performance through the daylight control. Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the school building design process, because of lack of previous studies on the light environment of student and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. ECOTECT simulation were performed using weather data. As a result, ECOTECT simulation are performed for daylight autonomy and useful daylight illuminance. Using this data, Window planing is to propose and effective method in the early stages of design.

광화이버 및 Fresnel lens 적용 집광식 자연채광 시스템의 이용을 통한 조명에너지의 절감 : 시뮬레이션 및 실측 비교 (Electric lighting energy saving through the use of a Fresnel lens based fiber-optic solar lighting system : Simulation and measurements)

  • 정해준;김원식;김영민;한현주;천원기
    • 에너지공학
    • /
    • 제26권1호
    • /
    • pp.34-44
    • /
    • 2017
  • 본 연구에서는 2축의 태양추적장치에 프레넬 렌즈를 장착한 fiber-optic 설비형 자연채광시스템의 효율성에 대하여 이론적 분석을 수행하였다. ECOTECT와 RADIANCE를 기반으로 시뮬레이션 모델을 개발하여 다양한 조건하에서 자연채광 시스템뿐만 아니라 형광등을 이용한 인공조명에 대한 실내 조도분석과 함께 실측 데이터와의 비교연구를 수행하였다. 형광등을 이용한 실내조명의 경우, 평균조도는 사무실 실내 조도 기준을(KS A 3011 일반 사무실 [G]등급[300-400-600lux]) 충분히 만족하는 결과를 보여주었다. 한편, 디퓨져를 사용한 자연채광시스템의 경우도 사무실 실내 조도 기준을 넘는 것으로 나타났다.

광화이버 및 Fresnel lens 적용 집광식 자연채광 시스템의 이용을 통한 조명에너지의 절감: 시뮬레이션 및 실측 비교 (Electric Lighting Energy Saving Through the Use of A Fresnel Lens Based Fiber-optic Solar Lighting System: Simulation and Measurements)

  • 정해준;김원식;김영민;한현주;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제37권3호
    • /
    • pp.1-12
    • /
    • 2017
  • This paper deals with the effectiveness of a fiber optic solar lighting system that uses a Fresnel lens mounted on a two-axis solar tracker. A series of comparative analyses were made concerning its performance as compared to fluorescent lighting by using a simulation model based on ECOTECT and RADIANCE as well as referring to actual data. ECOTECT was used to model the test room (space) while RADIANCE was used for its indoor lighting conditions (environment). It was found that the average indoor light levels of fluorescent lighting fully satisfy the KS standard (KS A 3011, general office, class [G]: 300-400-600 lux) whereas those of the solar lighting with light diffusers depends on the occlusion factor of roller shades installed on the south window.

블라인드PV 시스템의 적용성 검증을 위한 주광 특성 및 일사량 분석 시뮬레이션 (Analysis of Daylight Distributions and Solar Radiation to Verify the Applicability of Blind PV Systems Using Simulation)

  • 홍성관;최안섭
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.1-9
    • /
    • 2011
  • Daylight provides residents with good visual environment. And available daylight in inside provides positive influence on psychological and physiological aspects. Also, sunlight can be converted directly into electricity using PV(photovoltaic) power generation. This study was to analyze characteristics of daylight distributions, calculate an amount of solar radiation and a PV power generation on the building facade using Radiance and Ecotect simulation programs. Ultimately, the purpose of this study is to verify the applicability of Blind PV systems.

Ray-Tracing Method를 이용한 일영면적 산정방식 고찰 (A Study on the Calculation of Overshadowing Area by Ray-Tracing Method)

  • 최정민;조성우
    • 한국태양에너지학회 논문집
    • /
    • 제31권3호
    • /
    • pp.36-41
    • /
    • 2011
  • Nowadays, the solar expose right is very important with people's life. Therefore, in calculating the sunshine hours, the point analysis and area analysis methods are used in previous studies. Previous two methods have merits and faults. Therefore, ray-tracing method is used as a alternative. Ray-tracing method is adopted by the software of Autodesk Ecotect which is a widely used program by the architectural company and academic university. In this study first, ray-tracing methodology is studied with how to calculate the overshadowing area and, secondly, the sensitivity of the two major factors, overshadowing accuracy and sky subdivision, is analyzed. With these results, appropriate application of the ray-tracing method is presented.

치유환경을 위한 광선반 부착방법에 따른 노인요양시설 침실 내 자연채광 유입 환경 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 - (A study on Daylighting inducement within bedroom of Elderly care facility by light shelf attaching method for Therapeutic environment - By Dynamic Daylight Simulation Using Weather Data -)

  • 조주영;이기호;윤영일;이효원
    • KIEAE Journal
    • /
    • 제11권6호
    • /
    • pp.71-79
    • /
    • 2011
  • There are high recognitions on the importance of comforts in Elderly living environment, but the circumstance is that studies on seniors facility space itself are approached only in planning level, and studies on lighting environment which is significantly associated with the comfort in the indoor environment of seniors where they actually spend the majority of their time are not that active. This study was intended to deduce cozy bedroom environment to which existing elderly care facility can be improved by using light shelf the lighting system with the advantage of being able to serve both as building sun visor and lighting window simultaneously in order to analyze the interior environment of bedroom space of elderly care facility the indoor space where the aged spend the majority of their life and examine the directions for the improvement of existing building lighting system through remodeling and renovation. In this study, lighting performance analysis was done in a way that the windows of the bedroom unit in existing facility were set in southbound direction based on two standard types and were put under initial simulation with the use of Autodesk Revit 2011, and after the simulation results were converted to Green Building Studio gbXML file to be used in ECOTECT, Daylight Autonomy a dynamic simulation and static natural lighting simulation the existing method of calculating daylight factors were deduced through Ecotect Analysis 2011. In conclusion, exiting standard model was found in such a condition that the daylight factors for both type A and type B were above 5% the proper standard value, and required improvement. In case light shelf the natural lighting system was attached, the daylight factor was improved to proper standard value for type A, and also was improved above existing facility for type B.

공동주택의 판상형과 타워형 에너지 성능 비교 분석 (Energy Performance Analysis the Common House Pansang Type and Tower)

  • 윤성민;이경희;안영철
    • 동력기계공학회지
    • /
    • 제17권3호
    • /
    • pp.57-64
    • /
    • 2013
  • This study focus on the analysis of the energy performance in accordance with apartment houses arrangement type by using Ecotect Analysis. Korea, energy-poor country, the rate of dependence on imports amount to 94%, have to reduce energy consumption part of building except in industry and transport which affect the economic. Apartment houses are built in various forms in order to reduce energy, are modelled in each window area ratio, shape, orientation, climate through simulation. Through this study, we can analyze energy performance by form, window area ratio, orientation, climate change and know the optimal elements by the form. In particular, although there have been studied research on the window area ratio and research related to the arrangement form, determined that the information on the regional climate characteristics and the direction of placement is less than existing research. To supplement those problem, adding to seven direction(West, S-60-W, S-30-W, South, S-30-E, S-60-E, East) and climatic element(southern region) is characteristic of this study. The form of apartment houses was modelled for apartment houses built in the 10 years since. And each modeling were analyzed by Ecotect Analysis.

농어촌주택 표준설계의 유용조도 분석에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 - (The study on the Analysis of Useful Daylight Illuminance in rural standard house model - By Dynamic Daylight Simulation Using Weather Data -)

  • 윤영일;송정석;이효원
    • KIEAE Journal
    • /
    • 제11권1호
    • /
    • pp.47-55
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the Rural standard house models design process, because of lack of previous studies on elderly-light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

요양시설의 유용조도 분석에 관한 연구 -기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로- (The Study on the Analysis of Useful Daylight Illuminance in Care Facilities - By Dynamic Daylight Simulation Using Weather Data -)

  • 윤영일;조주영;이효원
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제17권1호
    • /
    • pp.33-40
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the care facility design process, because of lack of previous studies on elderly- light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

편측창에서 창개구부의 형상이 천공상태별 채광성능에 미치는 영향 (Effects of Different Fenestration Configurations on Daylighting Performance in Unilateral Window under Clear and Overcast Sky Conditions)

  • 술타나 아즈미리;김정태
    • KIEAE Journal
    • /
    • 제9권5호
    • /
    • pp.105-113
    • /
    • 2009
  • Daylighting provides the opportunity for both energy savings and improved visual comfort. An accurate estimation of the amount of daylight entering a building is the key step for daylight designing. This research aims to assess comparative daylighting performance of four different configurations of fenestration in case of unilateral windows and their variation under clear and overcast sky conditions. The selected window openings in this study were single punched, double punched, multiple punched and clerestory, and the area was same for each type of window. The experiment was designed for an office space using 1/10 scale model. Daylighting performance was evaluated by measuring the illuminance on work-plane height using Agilent data logger and photometric sensor Li-Cor. Thecomputer program ECOTECT was also used to simulate the pattern of interior illuminance distribution. Clerestory window showed the best performance in term of both illuminance level and distribution in the experiment. Multiple punched window provided more uniform illuminance distribution than single punched window. Lowest daylighting performance in the experiment was shown by double punched window.