• Title/Summary/Keyword: ECG signals

Search Result 370, Processing Time 0.031 seconds

Estimation of Instantaneous Bandwidth and Noise Rejection of ECG signals for 24-hours Continuous Health Monitoring System (24시간 건강 모니터링 시스템을 위한 심전도 신호의 순시 대역폭 추정 및 잡음 제거)

  • Song, Min;Choe, Jin-Myoung;Lee, He-Young
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.89-92
    • /
    • 2001
  • For the diagnosis of arrhythmia in the heart system, the QRS complex of ECG signals is used in many cases. The rejection of the noise in ECG signals is important to acquisition of exact QRS complex. This paper presents some experimental results about instantaneous bandwidth estimation and noise rejection of ECG signals with the purpose of rejection of the 60 Hz power noise and the motion artifacts such as EMG signals and contact noise. ECG signals corrupted by noise are cleaned by using the variable bandwidth filter. For the filtering of ECG signals with noise, the instantaneous bandwidth of the signals is estimated by analysis of time-frequency representation of ECG signal.

  • PDF

A Portable ECG System Coupled with a Smartphone (스마트폰과 연동한 휴대용 심전도계)

  • Kim, Kiwan;An, Jonghyun;Park, Kwangmin
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.1
    • /
    • pp.7-11
    • /
    • 2021
  • The electrocardiogram(ECG) and heart rates are essential for diagnosing heart disease. However, conventional portable ECG devices are possible to only measure heart rates or have limitations in how and where they are measured. In this paper, a portable ECG system in which ECG waveforms and heart rates are displayed on smartphone screens is developed. A smartphone is used as display equipment instead of a computer screen for continuous monitoring. The developed ECG system filters and amplifies detected analog ECG signals. Next, it converts the amplified analog ECG signals into digital signals, then transmits to the smartphone via Bluetooth communication. This ECG system can display and store biomedical signals on a smartphone through the application. As a result, the waveform and heart rates of the developed portable ECG system has been confirmed to be similar to those of existing medical devices.

Technology Trends in Biometric Cryptosystem Based on Electrocardiogram Signals (심전도(Electrocardiogram) 신호를 이용한 생체암호시스템 기술 동향)

  • B.H. Chung;H.C. Kwon;J.G. Park
    • Electronics and Telecommunications Trends
    • /
    • v.38 no.5
    • /
    • pp.61-70
    • /
    • 2023
  • We investigated technological trends in an electrocardiogram (ECG)-based biometric cryptosystem that uses physiological features of ECG signals to provide personally identifiable cryptographic key generation and authentication services. The following technical details of the cryptosystem were investigated and analyzed: preprocessing of ECG signals, extraction of personally identifiable features, generation of quantified encryption keys from ECG signals, reproduction of ECG encryption keys under time-varying noise, and new security applications based on ECG signals. The cryptosystem can be used as a security technology to protect users from hacking, information leakage, and malfunctioning attacks in wearable/implantable medical devices, wireless body area networks, and mobile healthcare services.

A real-time QRS complex detection algorithm using topological mapping in ECG signals (심전도 신호의 위상학적 팹핑을 이용한 실시간 QRS 검출 알고리즘)

  • 이정환;정기삼;이병채;이명호
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.5
    • /
    • pp.48-58
    • /
    • 1998
  • In this paper, we proposed a new algorithm using characteristics of th ereconstructed phase trajectory by topological mapping developed for a real-tiem detection of the QRS complexes of ECG signals. Using fill-factor algorithm and mutual information algorithm which are in genral used to find out the chaotic characteristics of sampled signals, we inferred the proper mapping parameter, time delay, in ECG signals and investigated QRS detection rates with varying time delay in QRS complex detection. And we compared experimental time dealy with the theoretical one. As a result, it shows that the experimental time dealy which is proper in topological mapping from ECG signals is 20ms and theoretical time delays of fill-factor algorithm and mutual information algorithm are 20.+-.0.76ms and 28.+-.3.51ms, respectively. From these results, we could easily infer that the fill-factor algorithm in topological mapping from one-dimensional sampled ECG signals to two-dimensional vectors, is a useful algorithm for the detemination of the proper ECG signals to two-dimensional vectors, is a useful algorithm for the detemination of the proper time delay. Also with the proposed algorithm which is very simple and robust to low-frequency noise as like baseline wandering, we could detect QRS complex in real-time by simplifying preprocessing stages. For the evaluation, we implemented the proposed algorithm in C-language and applied the MIT/BIH arrhythmia database of 48 patients. The proposed algorithm provides a good performance, a 99.58% detection rate.

  • PDF

Distortion anaysis of digital filters for ECG signals (ECG 신호를 위한 디지탈 필터의 distortion 해석)

  • 남현도;안동준;이철희;장태규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.817-822
    • /
    • 1992
  • Distortion analysis of digital filters for the ECG signal processing is presented. Several band pass and band reject filters are designed for the analysis. Computer simulations are performed to compare the distortions of the Butterworth type filters and linear phase optimal fitters. The designed filters are applied to power line interference cancelling in ECG signals.

  • PDF

Wireless Three-Pad ECG System: Challenges, Design, and Evaluations

  • Cao, Huasong;Li, Haoming;Stocco, Leo;Leung, Victor C.M.
    • Journal of Communications and Networks
    • /
    • v.13 no.2
    • /
    • pp.113-124
    • /
    • 2011
  • Electrocardiography (ECG) is a widely accepted approach for monitoring of cardiac activity and clinical diagnosis of heart diseases. Since cardiologists have been well-trained to accept 12-lead ECG information, a huge number of ECG systems are using such number of electrodes and placement configuration to facilitate fast interpretation. Our goal is to design a wireless ECG system which renders conventional 12-lead ECG information.We propose the three-pad ECG system (W3ECG). W3ECG furthers the pad design idea of the single-pad approach. Signals obtained from these three pads, plus their placement information, make it possible to synthesize conventional 12-lead ECG signals.We provide one example of pad placement and evaluate its performance by examining ECG data of four patients available from online database. Feasibility test of our selected pad placement positions show comparable results with respect to the EASI lead system. Experimental results also exhibit high correlations between synthesized and directly observed 12-lead signals (9 out of 12 cross-correlation coefficients higher than 0.75).

A QRS Pattern Analysis Algorithm for ECG Signals (심전도신호의 QRS 패턴해석)

  • 황선철;권혁제
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.2
    • /
    • pp.131-138
    • /
    • 1991
  • This paper describes an algorithm of pattern analysis of ECG signals by significant points extraction method. The significant points can be extracted by modified zerocrossing method, which method determines the real significant point among the significant point candidates by zerocrossing method and slope rate of left side and right side. This modified zerocrossing method improves the accuracy of detection of real slgnficant polnt Position. This Paper also describes the pattern matching algorithm by a hierarchical AND/OR graph of ECG signals. The decomposition of ECG signals by a hierarchical AND/ OR graph can make the pattern matching process easy and fast, Furthermore the pattern matching to the significant points reduces the processing time of ECG analysis.

  • PDF

Abnormal Electrocardiogram Signal Detection Based on the BiLSTM Network

  • Asif, Husnain;Choe, Tae-Young
    • International Journal of Contents
    • /
    • v.18 no.2
    • /
    • pp.68-80
    • /
    • 2022
  • The health of the human heart is commonly measured using ECG (Electrocardiography) signals. To identify any anomaly in the human heart, the time-sequence of ECG signals is examined manually by a cardiologist or cardiac electrophysiologist. Lightweight anomaly detection on ECG signals in an embedded system is expected to be popular in the near future, because of the increasing number of heart disease symptoms. Some previous research uses deep learning networks such as LSTM and BiLSTM to detect anomaly signals without any handcrafted feature. Unfortunately, lightweight LSTMs show low precision and heavy LSTMs require heavy computing powers and volumes of labeled dataset for symptom classification. This paper proposes an ECG anomaly detection system based on two level BiLSTM for acceptable precision with lightweight networks, which is lightweight and usable at home. Also, this paper presents a new threshold technique which considers statistics of the current ECG pattern. This paper's proposed model with BiLSTM detects ECG signal anomaly in 0.467 ~ 1.0 F1 score, compared to 0.426 ~ 0.978 F1 score of the similar model with LSTM except one highly noisy dataset.

Real-Time Monitoring of ECG Signal under Ubiquitous Environment (유비쿼터스 환경 하의 실시간 심전도 신호 모니터링)

  • Kim, Jungjoon;Kim, Jin-Sub;Ryu, Chunha;Kim, Jeong-Hong;Park, Kil-Houm
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.9
    • /
    • pp.728-735
    • /
    • 2013
  • In this paper, we present a method of transmitting ECG signals in real-time mobile environment to be possible to implement the ubiquitous healthcare system. Because of the excessive amount of data transmission of ECG signals, it is necessary to propose a limitation to the real-time transmission. We propose a real-time electrocardiographic monitoring system based on the proposal of unusual waveform detection algorithm which detects the R-wave distortions from the arrhythmia ECG signals having unusual waveform of about 10% on average. It is very effective in terms of time and cost for medical staffs to monitor and analyze ECG signals for a long period of time. Monitoring unusual waveform by gradually adjusting the threshold values of potential and kurtosis makes the amount of data transmitted decrease and significance level of waveform to be enhanced. The unusual waveform detection algorithm is implemented with ubiquitous environment inter-working device client. It is applicable to ubiquitous healthcare system capable of real-time monitoring the ECG signal. While ensuring the mobility, it allows for real-time continuous monitoring of ECG signals.

Analysis of QRS-wave Using Wavelet Transform of Electrocardiogram (웨이블릿 변환을 이용한 심전도의 QRS파 신호 분석)

  • Choi, Chang-Hyun;Kim, Yong-Joo;Kim, Tae-Hyeong;Ahn, Yong-Hee;Shin, Dong-Ryeol
    • Journal of Biosystems Engineering
    • /
    • v.33 no.5
    • /
    • pp.317-325
    • /
    • 2008
  • The electrocardiogram (ECG) measurement system consists of I/O interface to input the ECG signals from two electrodes, FPGA (Field programmable gate arrays) module to process the signal conditioning, and real time module to control the system. The algorithms based on wavelet transform were developed to remove the noise of the ECG signals and to determine the QRS-waves. Triangular wave tests were conducted to determine the optimal factors of the wavelet filter by analyzing the SNRs (signal to noise ratios) and RMSEs (root mean square errors). The hybrid rule, soft method, and symlets of order 5 were selected as thresholding rule, thresholding method, and mother wavelet, respectively. The developed wavelet filter showed good performance to remove the noise of the triangular waves with 10.98 dB of SNR and 0.140 mV of RMSE. The ECG signals from a total of 6 subjects were measured at different measuring postures such as lying, sitting, and standing. The durations of QRS-waves, the amplitudes of R-waves, the intervals of RR-waves were analyzed by using the finite impulse response (FIR) filter and the developed wavelet filter. The wavelet filter showed good performance to determine the features of QRS-waves, but the FIR filter had some problems to detect the peaks of Q and S waves. The measuring postures affected accuracy and precision of the ECG signals. The noises of the ECG signals were increased due to the movement of the subject during measurement. The results showed that the wavelet filter was a useful tool to remove the noise of the ECG signals and to determine the features of the QRS-waves.