• Title/Summary/Keyword: ECG parameters

Search Result 139, Processing Time 0.022 seconds

Human Sensibility Measurement for Visual Picture Stimulus using Heart Rate Variability Analysis (심박변화 분석을 이용한 장면시자극에 대한 감성측정에 관한 연구)

  • 권의철;김동윤;김동선;임영훈;손진훈
    • Science of Emotion and Sensibility
    • /
    • v.1 no.1
    • /
    • pp.93-103
    • /
    • 1998
  • In this paper, we present change of human sensiblity when the 26 healthy female subjects were exposed with visual picture stimulus. We used Intermational Affective Picture System as the visual stimulus. The methods are AutoRegressive(AR) spectrum which is a linear method and Return Map which is a nonlinear mithod. SR spectrum may variability(HRV). The LF/HF of HRV and the variation of Return Map were analyzed from ECG signal of the female subjects. Return Map of RR intervals were analyzed by computiong the variation. When the subjets were stimulated by the pleasant pictures, LF/HF and variation were decreased compared with unpleasant stimulus, We may obtain good parameters for the measurement of the change of human sensibility for the visual picture stimulus.

  • PDF

A study on the Modeling of Nonlinear Properties of Biological Signal using Genetic Programming (유전자 프로그래밍을 이용한 생체 신호의 비선형 특성 모델링에 관한 연구)

  • Kim, Bo-Yeon;Park, Kwang-Suk
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.70-73
    • /
    • 1996
  • Many researchers had considered biological systems as linear systems. In many cases of biological systems, the phenomena that show the regular and periodic dynamics are considered the normal state. However, some clinical experiments reported, in some cases, the periodic signals represented the abnormal state. We assume that signals from human body system are generated from deterministic, intrinsic mechanisms and can be represented a simple equation that show nonlinear dynamics dependent on control parameters. The objective of our study is to model a nonlinear dynamics correctly from the nonlinear time series using the genetic programming method; to find a simple equation of nonlinear dynamics using collected time series and its nonlinear characteristics. We applied genetic programming to model RR interval of ECG that shows chaotic phenomena. We used 4 statistic measures and 2 fractal measures to estimate fitness of each chromosome, and could obtain good solutions of which chaotic features are similar.

  • PDF

Quantitative analysis of metabolites in Korean green tea using NMR

  • Choi, Kwang-Ho;Lee, Joon-Hwa
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.22 no.4
    • /
    • pp.132-138
    • /
    • 2018
  • The plucking season of green tea leaves is one of the important parameters that decide their metabolic quality. Here, we performed the identification and quantity analysis of the metabolites of the green tea using NMR spectroscopy. We assigned the $^1H$ resonances for sixteen metabolites. This analysis found that four metabolites, gallic acid, quinic acid, theobromine and ECG, exhibited clear discrimination of green teas by the three different grades, Ujeon, Sejak and Jungjak. Our results suggest that these four metabolites could be used for diagnostics for quality control of green tea.

P Wave Detection Algorithm through Adaptive Threshold and QRS Peak Variability (적응형 문턱치와 QRS피크 변화에 따른 P파 검출 알고리즘)

  • Cho, Ik-sung;Kim, Joo-Man;Lee, Wan-Jik;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.8
    • /
    • pp.1587-1595
    • /
    • 2016
  • P wave is cardiac parameters that represent the electrical and physiological characteristics, it is very important to diagnose atrial arrhythmia. However, It is very difficult to detect because of the small size compared to R wave and the various morphology. Several methods for detecting P wave has been proposed, such as frequency analysis and non-linear approach. However, in the case of conduction abnormality such as AV block or atrial arrhythmia, detection accuracy is at the lower level. We propose P wave detection algorithm through adaptive threshold and QRS peak variability. For this purpose, we detected Q, R, S wave from noise-free ECG signal through the preprocessing method. And then we classified three pattern of P wave by peak variability and detected adaptive window and threshold. The performance of P wave detection is evaluated by using 48 record of MIT-BIH arrhythmia database. The achieved scores indicate the average detection rate of 92.60%.

The Study of Driving Fatigue using HRV Analysis (HRV 분석을 이용한 운전피로도에 관한 연구)

  • 성홍모;차동익;김선웅;박세진;김철중;윤영로
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2003
  • The job of long distance driving is likely to be fatiguing and requires long period alertness and attention, which make considerable demands of the driver. Driving fatigue contributes to driver related with accidents and fatalities. In this study, we investigated the relationship between the number of hours of driving and driving fatigue using heart rate variability(HRV) signal. With a more traditional measure of overall variability (standard deviation, mean, spectral values of heart rate). Nonlinear characteristics of HRV signal were analyzed using Approximate Entropy (ApEn) and Poincare plot. Five subjects drive the four passenger vehicle twice. All experiment number was 40. The test route was about 300Km continuous long highway circuit and driving time was about 3 hours. During the driving, measures of electrocardiogram(ECG) were performed at intervals of 30min. HRV signal, derived from the ECG, was analyzed using time, frequency domain parameters and nonlinear characteristic. The significance of differences on the response to driving fatigue was determined by Student's t-test. Differences were considered significant when a p value < 0.05 was observed. In the results, mean heart rate(HRmean) decreased consistently with driving time, standard deviation of RR intervals(SDRR), standard deviation of the successive difference of the RR intervals(SDSD) increased until 90min. Hereafter, they were almost unchanging until the end of the test. Normalized low frequency component $(LF_{norm})$, ratio of low to high frequency component (LF/HF) increased. We used the Approximate Entropy(ApEn), Poincare plot method to describe the nonlinear characteristics of HRV signal. Nonlinear characteristics of HRV signals decreased with driving time. Statistical significant is appeared after 60 min in all parameters.

Diagnosis of Coronary Artery Disease in Patients with Chest Pain by Means of Magnetocardiography (흉통환자에서 심자도를 이용한 관상동맥질환의 진단)

  • Kwon, H.;Kim, K.;Kim, J.M.;Lee, Y.H.;Kim, T.E.;Lim, H.K.;Park, Y.K.;Ko, Y.G.;Chung, N.
    • Progress in Superconductivity
    • /
    • v.8 no.1
    • /
    • pp.46-53
    • /
    • 2006
  • Magnetocardiography(MCG) has been proposed as a novel and non-invasive diagnostic tool for the detection of cardiac electrical abnormality associated with myocardial ischemia. In our previous study, we have proposed a new classification method of MCG parameters, based on the different populations of the parameters between coronary artery disease(CAD) patients, symptomatic patients and healthy volunteers. We used four parameters, representing the directional changes of the electrical activity in the period of an R-ST-T interval. In patients with chest pain and without ST-segment elevation, who were selected consecutively from all patients admitted to the hospital in 2004, the patients with CAD could be classified with a higher sensitivity than conventional methods, showing that the proposed method can be useful for the diagnosis of CAD with MCG. In this study, we examined the validity of the algorithm with the prior probability distribution in diagnosis of new patients admitted to the hospital in 2005. In the results, presence of CAD could be found with sensitivity and specificity of 81.3% and 71.4%, respectively, in patients with chest pain and non-diagnostic ECG findings.

  • PDF

Variation of parameters according to cardiac cycle length, evaluated by TDI in children (소아에서 심장 주기 시간 변화에 따른 조직 도플러 지표들의 변화양상)

  • Lee, Chang-Hyun;Kim, Jae-Kwang;Jin, Hyun-Seung;Park, Kie-Young;Kim, Bong-Seong;Han, Myung-Ki
    • Clinical and Experimental Pediatrics
    • /
    • v.52 no.3
    • /
    • pp.339-345
    • /
    • 2009
  • Purpose : This study aimed to determine the variation in parameters according to cardiac cycle length (CL; time interval between the QRS peaks on ECG) in children by using the conventional pulsed Doppler and tissue Doppler imaging echocardiography. Methods : Eighteen children with an anatomically normal heart were enrolled for the study. All children were examined by conventional and pulsed Doppler echocardiography at Gangneung Asan hospital between July 2006 and June 2007. We measured the CLs, mitral inflow velocities (E,A) and tissue Doppler imaging (TDI) parameters (s', e', a') from apical 4-chamber view. The TDI parameters were measured at the lateral (Lat) and septal (Sep) part of the mitral valve. All parameters were measured at 6 to 18 consecutive beats from each child. We then evaluated the linear correlation between CL and each parameter. Results : The mean age was $3.6{\pm}0.5$ years (M:F=8:10). There were significantly negative linear correlations between CL and A, Lat s', Lat a', Sep s', Sep e', Sep a' (P<0.01). There were significantly positive linear correlations between CL and E/A, Lat e'/a', Sep e'/a' (P<0.01). However, the E and Lat e' were not correlated with CL (P=0.229 and 0.221, respectively). Conclusion : This study showed that the values of the left ventricular functional parameters were changed according to CL. From our results, it is imperative to carefully examine beat-to-beat variations in children.

Adsorption Isotherms of Catechin Compounds on (+)Catechin-MIP

  • Jin, Yinzhe;Wan, Xiaolong;Row, Kyung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.8
    • /
    • pp.1549-1553
    • /
    • 2008
  • A molecular imprinted polymer (MIP) using (+)catechin ((+)C) as a template and acrylamide (AM) as a functional monomer was prepared. Acetonitrile was used as the porogen with ethylene glycol dimethacrylate (EGDMA) as the crosslinker and 2,2'-azobis(isobutyronitrile) (AIBN) as the initiator. The adsorption isotherms in the MIP were measured and the parameters of the equilibrium isotherms were estimated by linear and nonlinear regression analyses. The linear equation for original concentration and adsorpted concentrations was then expressed, and the adsorption equilibrium data were correlated into Langmuir, Freundlich, quadratic, and Langmuir Extension isotherm models. The mixture compounds of (+)C and epicatechin (EC) show competitive adsorption on specific binding sites of the (+)catechin-MIP. The adsorption concentrations of (+)C, epicatechin (EC), epicatechin gallate (ECG), and epigallocatechin gallate (EGCG), on the (+)catechin-molecular imprinted polymer were compared. Through the analysis, the (+)catechin-molecular imprinted polymer showed higher adsorption ability than blank polymer which was synthesized molecular imprinted polymer without (+)catechin. Furthermore, the competitive Langmuir isotherms were applied to the mixture compounds of (+)C and EC.

The Unconstrained Sleep Monitoring System for Home Healthcare using Air Mattress and Digital Signal Processing (공기 매트리스와 디지털 신호처리를 이용한 홈헬스케어용 무구속 수면 모니터링 시스템)

  • Chee, Young-Joon;Park, Kwang-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.493-496
    • /
    • 2005
  • For home healthcare, the unconstrained measurement of physiological signal is highly required to avoid the inconvenience of users. The recording and analysis of the fundamental parameters during sleep like respiration and heart beat provide valuable information on his/her healthcare. Using the air mattress sensor system, the respiration and heart beat movements can be measured without any harness or sensor on the subject's body. The differential measurement technique between two air cells is adopted to enhance the sensitivity. The balancing tube between two air cells is used to increase the robustness against postural changes during the measurement period. The meaningful frequency range could be selected by the pneumatic filter with balancing tube. ECG (Electrocardiography) and respiration sensor (plethysmography) were measured for comparison with the signal from air mattress. To extract the heart beat information from air pressure sensor, digital signal processing technique was used. The accuracy for breathing interval and heart beat monitoring was acceptable. It shows the potentials of air mattress sensor system to be the unconstrained home sleep monitoring system.

  • PDF

Analysis of Biosignal Variations caused by Epidural Anesthesia (경막외마취에 따른 생체신호 변화의 분석)

  • 전영주;임재중
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.275-283
    • /
    • 2001
  • This study was performed to extract and analyze the biosignals to find the relationship between the level of anesthesia and the variations of physiological parameters during epidural anesthesia. Seven male and twenty female patients(ages from 45 to 70 years old) were participated for the experiment, and ECGs, PPGs, SKTs, SCRs were obtained during anesthesia. As results, the HF/LF ratios of HRV were decreased after the injection anesthetics. For skin temperatures, values measured from the palm was reduced and the temperatures from four channels, measured from armpit through the right side of the body, were increased. SCRs were decreased for all channels after the injection of anesthetics. However the heart rate and PPGs showed no significant changes. It was concluded that the injection of anesthetics result the changes in biosignals, and it could be explained by the degree of the sympathetic and/or parasympathetic nerve activities. Results of this study could provide the valuable information for the estimation of level for the spinal and general anesthesia, and could be extended to the development of a system which could quantify the level of anesthesia.

  • PDF