• 제목/요약/키워드: ECG measurement

검색결과 219건 처리시간 0.024초

헬스케어 가방의 ECG 센서 전극 위치에 따른 신호 분석 (Signal Analysis According to the Position of the ECG Sensor Electrode in Healthcare Backpack)

  • 이현석;정완영
    • 센서학회지
    • /
    • 제23권6호
    • /
    • pp.402-408
    • /
    • 2014
  • Heart rate is one of the most important signal to monitor the health condition of the patient or exerciser. Various wearable devices have been developed for the continuous monitoring of ECG signal from human body during exercise. Among these, ECG chest belt has been widely used. However wearing chest belt with ECG sensor is uncomfortable in normal life due to the electrode contact between metal electrodes of ECG sensor and skin of the human body. So we develop the royal healthcare backpack that can measure ECG signal without skin contact by using capacitor-type ECG sensor. The position of the measurement point is critical to collect a clear ECG signal in the capacitive ECG measurement from backpack. Various tests were conducted to find the optimal ECG measurement position which has less noise and could get strong and clear ECG signal during exercise, walking, hiking, mountain climbing and cycling.

태아 ECG 추출 기능을 가지는 모바일 심전도 측정 시스템 설계 (Mobile ECG Measurement System Design with Fetal ECG Extraction Capability)

  • 최철형;김영필;김시경;유정봉;서봉균
    • 전기학회논문지
    • /
    • 제66권2호
    • /
    • pp.431-438
    • /
    • 2017
  • In this paper, the abdomen ECG(AECG) is employed to measure the mother's ECG instead of the conventioanl thoracic ECG measurement. The fetus ECG signal can be extracted from the AECG using an algorithm that utilizes the mobile fetal ECG measurement platform, which is based on the BLE (Bluetooth Low Energy). The algorithm has been implemented by using a replacement processor processed directly from the platform BLE instead of the large statistical data processing required in the ICA(Independent component analysis). The proposed algorithm can be implemented on a mobile BLE wireless ECG system hardware platform to process the maternal ECG. Wireless technology can realize a compact, low-power radio system for short distance communication and the IOT(Intenet of Things) enables the transmission of real-time ECG data. It was also implemented in the form of a compact module in order for mothers to be able to download and store the collected ECG data without having to interrupt or move the logger, and later link the module to a computer for downloading and analyzing the data. A mobile ECG measurement prototype is manufactured and tested to measure the FECG for pregnant women. The experimental results verify a real-time FECG extraction capability for the proposed system. In this paper, we propose an ECG measurement system that shows approximately 91.65% similarity to the MIT database and the conventional algorithm and SNR performance about 10% better.

간접접촉 심전도 측정에서의 오른발구동 접지의 효과와 한계 (The Effect and the Limitation of Driven-right-leg Ground on Indirect-contact ECG measurement)

  • 임용규
    • 대한의용생체공학회:의공학회지
    • /
    • 제39권2호
    • /
    • pp.103-108
    • /
    • 2018
  • This study reviews the common-mode noise model of indirect-contact ECG measurement which uses capacitive electrode and capacitive ground, and shows the reason of the large common-mode noise in indirect-contact ECG. And then, this study shows driven-right-leg ground in indirect-contact ECG measurement, and reviews how the driven-right-leg ground reduces the common-mode noise. This study then analyzes the relation between the effective area of the indirect-contact ground and the gain of the driven-right-leg circuit. This study introduces the output voltage saturation of the driven-right-leg circuit, which occurs frequently in indirect-contact ECG measurement with the condition of the high ground impedance. This study then shows the effect of the driven-right-leg circuit saturation on the common-mode noise.

일상생활 중 건강모니터링을 위한 착용형 심전도계측 시스템 개발 (Development of the wearable ECG measurement system for health monitoring during daily life)

  • 노윤홍;정도운
    • 센서학회지
    • /
    • 제19권1호
    • /
    • pp.43-51
    • /
    • 2010
  • In this study, wearable ECG measurement system was implemented for health monitoring during daily life. A wearable belt-type ECG electrode worn around the chest by measuring the real-time ECG is produced in order to minimize the inconvenience in wearing. The measured ECG signal is transmitted via an ultra low power consumption wireless data communications unit to personal computer using Zigbee-compatible wireless sensor node. The ECG monitoring program is developed at end user which is personal computer. The measured ECG contains many noises mainly due to motion artifacts. For ECG signal processing, adaptive filtering process is proposed which can reduce motion artifacts efficiently and accurately than digital filter. The experimental results show that a reliable performance with high quality ECG signal can be achieved using this wearable ECG monitoring system.

유비쿼터스 헬스 케어 적용을 위한 의자 부착형 무선 심전도 측정 시스템 구현 (Implementation of Wireless ECG Measurement System Attaching in Chair for Ubiquitous Health Care Environment)

  • 예수영;백승완;김지철;전계록
    • 한국전기전자재료학회논문지
    • /
    • 제21권8호
    • /
    • pp.776-781
    • /
    • 2008
  • In this study, ubiquitous health care system attaching in chair to monitor ECG for health care was developed at the unconsciousness state. The system conveniently and simple measured ECG at non-consciousness. We measured the contact impedance to skin-electrode of metal mesh electrodes of the system. Contact impedance enable the electrode to use for ECG measurement. The results are that the impedance of the metal mesh electrodes according to sizes is low when the size is 4$cm^2$. As the result, when the size of the metal mesh electrode is 4$cm^2$, the electrode is fit for ECG measurement. We can acquired by positing the arm on the metal mesh electrode. The ECG signal was detected using a high-input-impedance bio-amplifier, and then passed filter circuitry. The measured signal transmitted to a PC through the bluetooth wireless communication and monitored. Data of the non-constrained ECG system attaching in chair is noise-data when comparing metal mesh electrode with the Ag/Agcl electrode but the data is significant to monitor ECG for check the body state.

3D패턴을 이용한 노인용 u-헬스케어 의복의 심전도 측정 연구 (Improvement of ECG Measurement for the Elderly's U-healthcare Clothing Using 3D Tight-fit Pattern)

  • 박해준;신승철;손부현;홍경희
    • 한국의류산업학회지
    • /
    • 제10권5호
    • /
    • pp.676-682
    • /
    • 2008
  • In this study a guideline of the 3D-fit pattern for the ECG(electrocardiogram) measurement of elderly's u-healthcare clothes was proposed. In the screening test of the ECG measurement band, ECG peak band was observable at the band pressure of 0.20 kPa. By employing a 3D body image, tight-fit 3D patterns were made at two different reduction rates of 21%(pattern 1) and 33%(pattern 2), and corresponding pressure of both of the clothes were 0.25 kPa and 0.54 kPa, respectively. Typical waves of ECG were found in both stationary and moving position. In terms of the subjective evaluation of the u-healthcare clothes when worn, it was confirmed that reduction pattern 1(0.25 kPa) conveyed comfortable clothing pressure and pleasantness, which is very close to the result of screening test of ECG band experiment. As results, it is recommended that reduction rate should be adjusted, so that clothing pressure is about 0.2 kPa for the elderly's comfortable and efficient u-healthcare clothes.

간접접촉 심전도 측정용 전극의 주파수 특성 (Frequency Response of the electrode for Indirect-contact ECG)

  • 임용규
    • 대한의용생체공학회:의공학회지
    • /
    • 제29권3호
    • /
    • pp.249-253
    • /
    • 2008
  • The indirect-contact ECG (IDC-ECG) was introduced by a prior study for daily non-intrusive measurements. To improve the signal quality and to extend the application area of IDC-ECG, close study of the frequency characteristics of the IDC-ECG is necessary. In this study, the frequency response of the active electrode for several sample clothes was measured under conditions of actual IDC-ECG measurement with human body. Higher gain in low frequency range than expected by prior study was observed. In addition to it, wide variation in gain according to the cloth type in the low frequency range was observed. Variation in gain caused by moisture variation in the clothes was also observed. This study shows that the parallel R-C connection is proper for electrode model and the resistive factor is influenced by moisture in the clothes. This study is the first that provides the frequency response of the electrode in the actual indirect-contact ECG measurement and it is expected that the results will be helpful to improve the indirect-contact ECG method.

침대에 부착된 용량성 전극 배열을 이용한 수면 중의 심전도 측정 (ECG Measurement Method during Sleep with Array of Capacitive Electrodes Attached to Bed)

  • 임용규;김고근;박광석;정도언
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.521-524
    • /
    • 2005
  • In order to measure ECG in daily life, a new ECG measurement method on bed was developed. The provided method does not require any direct conductive contact between the instrument and bare skin, so that it does not cause the uncomfortable feel of touch and the possible skin trouble which are typical shortcomings of the conventional conductive contact ECG measurement. The provided method utilized an array of high-input-impedance active electrodes fixed on the mattress and an indirect-skin-contact ground made of a large conductive textile sheet and laid on lower area of the mattress. A thin cotton bedcover covered the mattress, the electrodes, and the conductive textile and subjects lay on the mattress over the bedcover. ECG was obtained successfully. However its signal quality is lower and the motion artifact is larger than direct-contact measurement. Careful measurement setup was needed to reduce the motion artifact originated from variation in static electricity. From the ECG obtained by the provided method, R-peak could be discriminated easily and the information about the position and the posture of the subject could be obtained.

  • PDF

PPG 및 ECG 센서를 이용한 혈압추정 기법 개발 (Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors)

  • 박현문;이정철;황태호
    • 한국전자통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.1257-1264
    • /
    • 2019
  • 기존의 Cuff 기반의 혈압(Blood Pressure)측정 방법은 연속적인 실시간 혈압측정에는 한계를 갖는다. 이러한 이유로 ECG와 PPG 센서 신호를 상호융합한 다양한 혈압추정이 이루어졌다. 그러나 PPG 중심에 측정기법은 AC 노이즈, 작은 맥동, 비박동 등의 많은 문제를 지니고 있다. 본 논문은 ECG와 PPG 관계에 발생하는 맥파전달시간(PTT)과 맥파속도(PWV)를 이용하여 혈압을 추론기법이다. 신호 피크를 이용하는 HRF(Height Ratio Features)에 비해, 본 제안방식은 ECG, PPG의 최고점 혹은 최저점을 사용한 시차를 이용해 추정하기 때문에 PPG 센싱 시그널의 오류에도 안정적인 추출이 가능한 장점이 있다. 본 논문에서 제안 방법을 이용하여 25만 회의 혈압측정의 결과 ±28.5%의 정확도를 갖는 혈압 추정기법을 제시할 수 있었다.

Implementation of Extended Kalman Filter for Real-Time Noncontact ECG Signal Acquisition in Android-Based Mobile Monitoring System

  • Rachim, Vega Pradana;Kang, Sung-Chul;Chung, Wan-Young;Kwon, Tae-Ha
    • 센서학회지
    • /
    • 제23권1호
    • /
    • pp.7-14
    • /
    • 2014
  • Noncontact electrocardiogram (ECG) measurement using capacitive-coupled technique is a very reliable long-term noninvasive health-care remote monitoring system. It can be used continuously without interrupting the daily activities of the user and is one of the most promising developments in health-care technology. However, ECG signal is a very small electric signal. A robust system is needed to separate the clean ECG signal from noise in the measurement environment. Noise may come from many sources around the system, for example, bad contact between the sensor and body, common-mode electrical noise, movement artifacts, and triboelectric effect. Thus, in this paper, the extended Kalman filter (EKF) is applied to denoise a real-time ECG signal in capacitive-coupled sensors. The ECG signal becomes highly stable and noise-free by combining the common analog signal processing and the digital EKF in the processing step. Furthermore, to achieve ubiquitous monitoring, android-based application is developed to process the heart rate in a realtime ECG measurement.