• 제목/요약/키워드: ECG holter

검색결과 32건 처리시간 0.019초

시각화 프로그래밍에 의한 Holter 분석 시스템 개발 (Development of Holter Analysis System by Visual Programming)

  • 이세진;이경중;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.45-50
    • /
    • 1997
  • In this paper, we designed a Molter analysis system using the visual programming method It differs from the existing analysis system in that the various signal processing algorithms represented by icons were designed by GUI concept which provide unskilled user with easy and convenient analysis environment. In order to analyze ECG signal. we only select the icon representing an algorithm to be applied by mouse and arrange the selected icons upon the order to be jlrocessed on screen. As a result it provides a convenient usage and flexibility of analysis. Also, we can find the optimal algorithm for the ambulatory ECG analysis by comparing the several results obtained from the various analysis configuration.

  • PDF

An SPC-Based Forward-Backward Algorithm for Arrhythmic Beat Detection and Classification

  • Jiang, Bernard C.;Yang, Wen-Hung;Yang, Chi-Yu
    • Industrial Engineering and Management Systems
    • /
    • 제12권4호
    • /
    • pp.380-388
    • /
    • 2013
  • Large variation in electrocardiogram (ECG) waveforms continues to present challenges in defining R-wave locations in ECG signals. This research presents a procedure to extract the R-wave locations by forward-backward (FB) algorithm and classify the arrhythmic beat conditions by using RR intervals. The FB algorithm shows forward and backward searching rules from QRS onset and eliminates lower-amplitude signals near the baseline using a statistical process control concept. The proposed algorithm was trained the optimal parameters by using MIT-BIH arrhythmia database (MITDB), and it was verified by actual Holter ECG signals from a local hospital. The signals are classified into normal (N) and three arrhythmia beat types including premature ventricular contraction (PVC), ventricular flutter/fibrillation (VF), and second-degree heart block (BII) beat. This work produces 98.54% accuracy in the detection of R-wave location; 98.68% for N beats; 91.17% for PVC beats; and 87.2% for VF beats in the collected Holter ECG signals, and the results are better than what are reported in literature.

Holter Data 압축 알고리즘에 관한 연구 -Piecewise Self-Affine Fractal Model을 이용한- (A Study on the Holter Data Compression Algorithm -Using Piecewise Self-Affine Fractal Model-)

  • 전영일;정형만
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권1호
    • /
    • pp.17-24
    • /
    • 1995
  • 본 논문은 iterated contractive transformations을 이용한 심전도 데이터 압축에 관한 새로운 방법을 제안한다. 이방법은 piecewise self-affine fractal interpolation(PSAFI)에 의해 심전도 신호의 임의 구간들을 표현한다. Piecewise self-affine fractal model은 자기자신의 수축적 유사 변환으로 구성된다고 볼 수 있는 이산 데이터에 사용된다. 제안된 알고리즘은 MIT/BIH arrhythmia 데이터베이스로 평가되었다. PSAFI는 주어진 압축율에서 기존의 직접 압축 방법보다 상대적으로 적은 재생 오차를 나타냈다. 샘플링 주파수는 400Hz이고 resolution은 12bits인 원래 신호에 대해 압축율이 883.9bps일때 평균재생오차(APRD)는 5.39%를 나타냈다.

  • PDF

휴대용 심전도 기기와 직물형 전극을 이용한 생체정보 측정용 밀착 의복 개발 (Development of Tight-Fitting Garments with a Portable ECG Monitor to Measure Vital Signs)

  • 정연희;김승환;양영모
    • 한국의류학회지
    • /
    • 제34권1호
    • /
    • pp.112-125
    • /
    • 2010
  • A Holter monitor is used for ECG monitoring of ambulatory daily life in hospital. However, the use of this apparatus causes skin allergies and discomfort in patients because of the attachment gel and tapes used to attach disposable electrodes to the skin. In this study, the development of tight-fitting clothing connected to a portable Holter monitor was proposed. In addition, the use of conductive fabrics as electrodes was proposed; this will enable the use of garments in u-health care for measuring ECG signals. The male subjects were university students in the ages of 20 to 24. Subjective wear sensations of the experimental garments were rated using seven Likert scales. A Likert type scale was used for the evaluation and a 7 point score indicates that it provided the best fit as a tight-fitting upper clothing. Clothing pressure was measured using an air-pack-type pressure sensor (model AMI 3037-2) at 4 locations (the conductive fabric electrode) As results, a male basic sloper for upper clothing was developed and that pattern was manipulated to the tight fit pattern by considering the reduction rate of the percentage stretch in the fabric. The developed tight-fitting garment was superior in terms of subjective sensation and 6t. The mean pressure of the garment with reduction rates of 40% in width and of 50% in length was 8.45gf/$cm^2$. A conductive fabric electrode was developed by considering the sewing method and the developed electrode was detected well. The ECG data were recorded for 13 hr 19 min 44 sec and the artifacts in the ECG signals were recorded for 9 hr 3 min 46 sec (total time: 22 hr 23 min 23 sec). The artifacts data were obtained during heavy activities.

침처치의 24시간 심박변이도 영향에 대한 비선형 분석 (Nonlinear analysis of cardiotonic effect of acupuncture treatment on heart rate variability assessed by 24-hour Holter monitoring)

  • 오달석;이전;김종열;최선미
    • 한국한의학연구원논문집
    • /
    • 제14권1호
    • /
    • pp.85-89
    • /
    • 2008
  • This study is to investigate cardiotonic effect of acupuncture on heart rate variability(HRV) analyzed by a nonlinear way(DFA, Detrended Fluctuation Analysis). It was designed as a randomized, single-blind, waiting list-controlled, cross-over study. We assessed heart rate and R-R intervals in Circadian electrocardiography with a Holter monitoring device for twelve hospitalized participants. The compatible analytical program, Zymed, was used for generating the signals of R-R intervals from 24 hour-ECG. In DFA analysis, we produced DFA alpha 1, alpha 2 parameters according to the process of Cygwin module of Linux server. We tested if there was any difference between HRV parameters using SPSS, a statistical package. There was no difference between acupuncture and no treatment group in DFA alpha 2 parameter {95% Confidence Interval (-)0.058 - 0.037, P = .565}. Two group all showed large intra-individual variations. Consequently, acupuncture treatment did not modulate the complexity of HRV in a DFA analysis. This study can be a rationale for acupuncture's properties on cardiovascular and autonomic systems.

  • PDF

Zero-Configuration을 이용한 무구속 Holter 심전도 데이터 고속 전송 시스템에 관한 연구 (A Study of Fast Data Transmission System for Unrestricted Holter ECG Using Zero-Configuration)

  • 이광현;임준우;김영길
    • 한국정보통신학회논문지
    • /
    • 제14권2호
    • /
    • pp.479-484
    • /
    • 2010
  • 의료기술의 발달과 인구의 고령화 및 생활양식의 변화로 건강에 관한 관심이 높아지고 있으며, 특히 의료 분야에서 헬스케어에 관한 연구가 활발하게 이루어지고 있다. 이러한 헬스케어 서비스를 제공하기 위해서는 생체 정보 수집센서에 관한 기술, 생체 신호 저장 기술, 저장된 데이터의 전송/분석이 필요하다. 본 연구에서는 이러한 헬스케어 서비스를 제공하기 위해 먼저 사용자의 행동을 보장할 수 있도록 많은 데이터를 저장할 수 있는 무구속 장치를 제안하였다. 그리고 저장된 데이터를 단 시간에 전송할 수 있는 방법에 대하여 연구하고 누구나 활용이 편리하게 자동으로 전송할 수 있는 시스템을 구현한다.

부정맥 신호의 조기진단을 위한 연속 심전도 모니터링 기기 개발 (Development of Continuous ECG Monitor for Early Diagnosis of Arrhythmia Signals)

  • 최정현;강민호;박준호;권기구;배태욱;박준모
    • 융합신호처리학회논문지
    • /
    • 제22권2호
    • /
    • pp.45-50
    • /
    • 2021
  • 최근 IT기술이 발달함에 따라 다양한 생체신호 측정 기기에 대한 연구 및 관심이 높아지고 있으나, 가장 대표적인 생체 신호 중 하나인 심전도, 특히 부정맥 신호 검출과 관련한 연구는 미비한 현실이다. 부정맥은 그 발병원인이 다양하며 발병이후 예후가 좋지 않으므로 조기진단을 통한 예방치료가 최선이다. 하지만 부정맥을 진단하기 위한 도구인 24시간 홀터 심전계는 사용지속시간의 제약, 일상생활로 인한 동잡음 분석의 어려움, 위험상황에서 사용자의 실시간 알람 기능에 단점을 보인다. 본 연구에서는 장시간 연속 측정이 가능한 심전도 및 맥박 모니터링 기기와 실시간 모니터링 앱, 분석용 소프트웨어를 개발하였으며, 측정한 값의 경향성을 확인하였다. 향후 연구에서는 심전도 신호 측정 분석의 정량적 결과 도출에 관한 연구가 필요하며, 이를 바탕으로 하는 부정맥 신호 검출 알고리즘 개발과 관련한 추가 연구를 진행해야 한다.

지그비 기반 심전계의 데이터 전송률과 소비 전력 분석 (Analysis of Data Transmission Rate and Power Consumption in Zigbee Based Electrocardiography)

  • 김남진;홍주현;이태수
    • 한국콘텐츠학회논문지
    • /
    • 제6권12호
    • /
    • pp.96-104
    • /
    • 2006
  • 본 연구에서는, 심전도 송수신 장치의 개발을 위한 지그비(Zigbee) 기반 무선 센서 모듈과 PDA(Personal Digital Assistant)의 데이터 전송률과 전력 소비에 대하여 분석 하였다. 데이터 전송률은 패킷(Packet) 구조에 의존적이며, 패킷을 2개의 심전도 데이터와 1개의 3축 가속도 벡터로 구성하였을 때, 초당 300 샘플의 전송률을 나타내었다. 두 개의 AAA 전지를 직렬로 연결하여, 센서 모듈의 동작 시간은 평균적으로 28시간 이었다. PDA의 전력 소비는 화면의 ON/OFF 여부와 시리얼 포트의 사용 여부 및 패턴에 의존적임을 알 수 있었다. 이러한 응용에서, PDA 동작 시간은 평균적으로 5시간 정도임을 확인하였으며, 이때, PDA는 논 블로킹 모드로 시리얼 포트로부터 전송된 데이터를 수신 한다. 결론적으로, 본 연구에서 개발된 장치를 24 시간 홀터(Holter) 심전계로 응용할 경우, 센서 모듈의 전력 소비와 전송 속도에는 문제가 없었으나, PDA는 전력 소모율에 문제가 있으며 이는 해결되어야할 과제이다.

  • PDF

임상시험 중 수면행위가 심박변이도에 미치는 영향 분석 (Assessment of covariate-effect of sleeping behavior on heart rate variability during a clinical trial)

  • 이전;오달석;이혜정;최선미;김종열
    • 한국한의학연구원논문집
    • /
    • 제13권3호
    • /
    • pp.97-103
    • /
    • 2007
  • The object of this study is to evaluate confounding effect of sleeping behavior on heart rate variability (HRV) in healthy volunteers during a randomized clinical trial. From 6 healthy volunteer, we acquired circadian electrocardiography(ECG) with a Holter monitoring device(DigiTrak Plus, Philips). The compatible analytical program, Zymed, was used for calculation of RR intervals of 24h ECG signal. Then, we generated HRV signals and calculated 9 HRV parameters in time domain and frequency domain for every 30 minute with Matlab 6.x software. We also encoded participants' activities as follows; stable condition(1), sleeping behavior(2), eating behavior(3), and undefined condition(4). Using SPSS 12.0, we tested if there was any difference between HRV parameters of day-time and night-time and between those of a subject in stable condition and in sleeping behavior. As a result, one of the most important parameter-LF/HF ratio, which indicates the autonomic balance between sympathetic and parasympathetic nervous systems, as same the other parameters, showed large inter-individual variations in circadian profiles. And, the mean LF/HF ratio of each participant was different between in stable condition and in sleeping behavior (p<.05). Consequently, the effect of sleeping behavior must be considered when one or more of HRV parameters, especially LF/HF ratio, are used as assessment index in clinical studies.

  • PDF

무선 데이터 통신망을 이용한 보행형 감시 시스템 개발에 관한 연구 (A Study on the Implementation of Ambulatory Monitoring System Using Wireless Data Communication Network)

  • 고성일;김영길
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권1호
    • /
    • pp.75-80
    • /
    • 1999
  • 홀터 심전계는 일반 심전계와 달리 활동중의 심전도를 기록하므로서 복잡한 심장질환을 효과적으로 모니터링할 수 있으나 24시간 동안의 심전도를 수집하여 진단하기 때문에 급작스런 심장질환에 대해서는 대처할 수 없다. 따라서 본 논문에서는 홀터 심전계와 같은 이동형 심전도 단말기에 900Mhz 대역을 사용하는 부선 데이터 통신망 인터페이스를 첨가하여 심장 이상으로 인한 급사위험이 있는 환자를 감시${\cdot}$관리할 수 있는 보행형 감시 시스템 모델을 제안하고 이동형 심전도 단말기와 담당 의사를 위한 휴대형 단말기를 구현함으로써 무선 데이터 통신망을 이용한 보행형 감시 시스템이 구현될 수 있음을 검증하였다.

  • PDF