• 제목/요약/키워드: ECG classification

검색결과 137건 처리시간 0.028초

선형예측법을 이용한 심전도 신호의 부호화와 특징추출 (Pulse-Coded Train and QRS Feature extraction Using Linear Prediction)

  • 송철규;이병채;정기삼;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.175-178
    • /
    • 1992
  • This paper proposes a method called linear prediction (a high performant technique in digital speech processing) for analyzing digital ECG signals. There are several significant properties indicating that ECG signals have an important feature in the residual error signal obtained after processing by Durbin's linear prediction algorithm. The ECG signal classification puts an emphasis on the residual error signal. For each ECG's QRS complex. the feature for recognition is obtained from a nonlinear transformation which transforms every residual error signal to set of three states pulse-cord train relative to the original ECG signal. The pulse-cord train has the advantage of easy implementation in digital hardware circuits to achive automated ECG diagnosis. The algorithm performs very well feature extraction in arrythmia detection. Using this method, our studies indicate that the PVC (premature ventricular contration) detection has a at least 90 percent sensityvity for arrythmia data.

  • PDF

심전도 자동 진단 알고리즘 및 장치 구현(I) - YECGA 개요 (An implementation of automated ECG interpretation algorithm and system(I) - Introduction of YECGA)

  • 권혁제;정기삼;정성진;최석준;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.175-178
    • /
    • 1996
  • The purpose of this thesis is the propose of various signal processing algorithm for the ECG(electrocardiogram) and the design of realtime automated ECG analyzer feasible with these algorithms. The algorithms are composed of (1)filtering procedure fer the estimation and removal of baseline drift, 60Hz power line interference, and muscle artifacts (2)detection procedure of QRS complex and P wave (3)typification procedure for the pattern classification according to the morphologies (4) selection of representative beat, significant point and wave boundary decision procedure and (5) parameter extraction and diagnosis procedure. All verifications are carried out between the algorithms proposed in this paper and other algorithms already proposed by many researchers, for the objective comparison in each procedure. The efficiency of proposed algorithms are demonstrated with the aid of internationally validated CSE database and the performances of filtering procedure are compared on artificial noise signal as well as actual ECG signals with appropriate noise components. for the comparison on the performance of designed automated ECG analyzer, the diagnosis results were compared with ECG analyzer manufactered by Fukuda denshi in Japan.

  • PDF

Abnormal Electrocardiogram Signal Detection Based on the BiLSTM Network

  • Asif, Husnain;Choe, Tae-Young
    • International Journal of Contents
    • /
    • 제18권2호
    • /
    • pp.68-80
    • /
    • 2022
  • The health of the human heart is commonly measured using ECG (Electrocardiography) signals. To identify any anomaly in the human heart, the time-sequence of ECG signals is examined manually by a cardiologist or cardiac electrophysiologist. Lightweight anomaly detection on ECG signals in an embedded system is expected to be popular in the near future, because of the increasing number of heart disease symptoms. Some previous research uses deep learning networks such as LSTM and BiLSTM to detect anomaly signals without any handcrafted feature. Unfortunately, lightweight LSTMs show low precision and heavy LSTMs require heavy computing powers and volumes of labeled dataset for symptom classification. This paper proposes an ECG anomaly detection system based on two level BiLSTM for acceptable precision with lightweight networks, which is lightweight and usable at home. Also, this paper presents a new threshold technique which considers statistics of the current ECG pattern. This paper's proposed model with BiLSTM detects ECG signal anomaly in 0.467 ~ 1.0 F1 score, compared to 0.426 ~ 0.978 F1 score of the similar model with LSTM except one highly noisy dataset.

귀 주변에서 측정한 유사 심전도 기반 개인 인증 시스템 개발 가능성 (Feasibility of Using Similar Electrocardiography Measured around the Ears to Develop a Personal Authentication System)

  • 최가영;박종윤;김다영;김연우;임지헌;황한정
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권1호
    • /
    • pp.42-47
    • /
    • 2020
  • A personal authentication system based on biosignals has received increasing attention due to its relatively high security as compared to traditional authentication systems based on a key and password. Electrocardiography (ECG) measured from the chest or wrist is one of the widely used biosignals to develop a personal authentication system. In this study, we investigated the feasibility of using similar ECG measured behind the ears to develop a personal authentication system. To this end, similar ECGs were measured from thirty subjects using a pair of three electrodes attached behind each of the ears during resting state during which the standard Lead-I ECG was also simultaneously measured from both wrists as baseline ECG. The three ECG components, Q, R, and S, were extracted for each subject as classification features, and authentication accuracy was estimated using support vector machine (SVM) based on a 5×5-fold cross-validation. The mean authentication accuracies of Lead I-ECG and similar ECG were 90.41 ± 8.26% and 81.15 ± 7.54%, respectively. Considering a chance level of 3.33% (=1/30), the mean authentication performance of similar ECG could demonstrate the feasibility of using similar ECG measured behind the ears on the development of a personal authentication system.

게임 지식 표현 기법을 이용한 심전도 신호의 패턴해석 알고리즘에 관한 연구 (An Algorithm for Pattern Classification of ECG Signals Using Frame Knowledge Representation Technique)

  • 신건수;이병채;정희교;이명호
    • 대한전기학회논문지
    • /
    • 제41권4호
    • /
    • pp.433-441
    • /
    • 1992
  • This paper describes an algorithm that can efficiently analyze the ECG signal using frame knowledge representation technique. Input to the analysis process is a set of significant points which have been extracted from an original sampled signal(lead II) by the syntactic peak recognition algorithm. The hierarchical property of ECG signal is represented by hierarchical AND/OR graph. The semantic information and constraints of the ECG signal are desctibed by frame. As the control mechanism for labeling points, the search mechanism with the mixed paradigms of data-driven and model driven hypothesis formation, scoring function, hypothesis modification network and instance inheritance are used. We used the CSE database in order to evaluate the performance of the proposed algorithm.

ECG 특징추출을 위한 하드웨어시스템의 설계 (Design of a hardware system for ECG feature extraction)

  • 이경중;윤형로;이명호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.697-700
    • /
    • 1988
  • This paper describes the design of a hardware system for ECG feature extraction based on pipeline processor consisting of three computers. ECG data is acquisited by 12 bit A/D converter with hardware QRS triggred detector. Four diagnostic parameters-heart, axis, and ST axis, and ST segment are used for the classification and the diagnosis of arrhythmia. The functions of the main CPU were distributed and processed with three microcomputers. Therefore the effective data process and the real time process using microcomputer can be obtained. The interconnection structure consisting of two common memory units is designed to decrease the delay time caused by data transfer between processors and designed by which the delay time can be taken 1% of one clock period.

  • PDF

ECG 특징추출을 위한 파이프라인 프로세서의 설계 (Design of Pipeline Processor for ECG Feature Extraction)

  • 이경중;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제9권1호
    • /
    • pp.79-86
    • /
    • 1988
  • This paper describes the design of a hardware systenl for ECG feature extraction based on pipeline processor consistinsf of three microcomputers. ECG data is acquisited by 12 bit A/D converter with hardware QRS triggered detector. Four diagnostic parameters parameters-heart rate, morPhology, axis, and 57 segment-are used for the classification and the diagnosis of arrhythmia. The functions of the main CPU were distributed and processed with three microcomputers. Therefore the effective data process and the real time process using microcomputer can be obtained. The interconnection structure consisting of two common memory units is designed to decrease the delay time caused by data transfer between processors and designed by which the delay time can be taken Loye of one clock period.

  • PDF

ECG 신호에서 단위패턴간 유사도분석을 이용한 부정맥 분류 알고리즘 (The classification of arrhythmia using similarity analysis between unit patterns at ECG signal)

  • 배정현;임승주;김정주;박성대;김정도
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2011년도 추계학술발표대회
    • /
    • pp.1399-1402
    • /
    • 2011
  • 본 논문에서는 조기 심실 수축과 조기 심방 수축을 검출함에 있어 정밀한 QRS 구간의 폭, 정확한 P파와 T파의 크기 및 위치를 크게 요구하지 않고, 데이터의 가공과 복잡한 알고리즘의 사용에 의해 발생하는 ECG 데이터의 변형과 손실을 최소화할 수 있으며, 또한 개인차 때문에 발생할 수 있는 오류를 최소화하기 위한 알고리즘을 제안한다. 이를 위해 ECG 신호를 각각의 단위 파형으로 분리한 후, 정상 R-R 간격을 가지는 파형을 기준으로 기준파형을 만들어, 각 파형과 기준파형사이의 패턴 대조 및 유사도 분석을 통해 조기 심실수축과 조기심방수축을 검출할 수 있도록 하였다.

2D-CNN 모델을 이용한 메타-전이학습 기반 부정맥 분류 (Arrhythmia classification based on meta-transfer learning using 2D-CNN model)

  • 김아현;염성웅;김경백
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2022년도 추계학술발표대회
    • /
    • pp.550-552
    • /
    • 2022
  • 최근 사물인터넷(IoT) 기기가 활성화됨에 따라 웨어러블 장치 환경에서 장기간 모니터링 및 수집이 가능해짐에 따라 생체 신호 처리 및 ECG 분석 연구가 활성화되고 있다. 그러나, ECG 데이터는 부정맥 비트의 불규칙적인 발생으로 인한 클래스 불균형 문제와 근육의 떨림 및 신호의 미약등과 같은 잡음으로 인해 낮은 신호 품질이 발생할 수 있으며 훈련용 공개데이터 세트가 작다는 특징을 갖는다. 이 논문에서는 ECG 1D 신호를 2D 스펙트로그램 이미지로 변환하여 잡음의 영향을 최소화하고 전이학습과 메타학습의 장점을 결합하여 클래스 불균형 문제와 소수의 데이터에서도 빠른 학습이 가능하다는 특징을 갖는다. 따라서, 이 논문에서는 ECG 스펙트럼 이미지를 사용하여 2D-CNN 메타-전이 학습 기반 부정맥 분류 기법을 제안한다.

무선센서네트워크 기반의 웨어러블 센서노드에서 3축 가속도 신호의 단채널 전송과 심전도 노이즈 제거에 대한 연구 (A Research for Removing ECG Noise and Transmitting 1-channel of 3-axis Accelerometer Signal in Wearable Sensor Node Based on WSN)

  • 이승철;정완영
    • 센서학회지
    • /
    • 제20권2호
    • /
    • pp.137-144
    • /
    • 2011
  • Wireless sensor network(WSN) has the potential to greatly effect many aspects of u-healthcare. By outfitting the potential with WSN, wearable sensor node can collects real-time data on physiological status and transmits through base station to server PC. However, there is a significant gap between WSN and healthcare. WSN has the limited resource about computing capability and data transmission according to bio-sensor sampling rates and channels to apply healthcare system. If a wearable node transmits ECG and accelerometer data of 4 channel sampled at 100 Hz, these data may occur high loss packets for transmitting human activity and ECG to server PC. Therefore current wearable sensor nodes have to solve above mentioned problems to be suited for u-healthcare system. Most WSN based activity and ECG monitoring system have been implemented some algorithms which are applied for signal vector magnitude(SVM) algorithm and ECG noise algorithm in server PC. In this paper, A wearable sensor node using integrated ECG and 3-axial accelerometer based on wireless sensor network is designed and developed. It can form multi-hop network with relay nodes to extend network range in WSN. Our wearable nodes can transmit 1-channel activity data processed activity classification data vector using SVM algorithm to 3-channel accelerometer data. ECG signals are contaminated with high frequency noise such as power line interference and muscle artifact. Our wearable sensor nodes can remove high frequency noise to clear original ECG signal for healthcare monitoring.