• Title/Summary/Keyword: ECG blood pressure

Search Result 118, Processing Time 0.033 seconds

Biological Signal Measurement, Archiving, and Communication System (SiMACS) (생체신호 측정 및 종합관리 시스템 (SiMACS))

  • Woo, Eung-Je;Park, Seung-Hun
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.49-52
    • /
    • 1994
  • We have developed a biological signal measurement, archiving, and communication system (SiMACS). The front end of the system is the intelligent data processing unit (IDPU) which includes ECG, EEG, EMG, blood pressure, respiration, temperature measurement modules, module control and data acquisition unit, real-time display and signal processing unit. IDPUS are connected to central data base unit through LAN(Ethernet). Workstations which receive signals from central DB and provide various signal analysis tools are also connected to the network. The developed PC-based SiMACS is described.

  • PDF

A Study of Physiology Signal Change by Air Conditioner Temperature Change (에어컨 온도변동에 따른 생리신호 변화에 관한 연구)

  • Kum, Jong-Soo;Kim, Dong-Gyu;Kim, Hyung-Chul
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.19 no.3
    • /
    • pp.502-509
    • /
    • 2007
  • This study evaluates thermal comfort by air conditioner temperature raising at the point of time that human body begins to adapt. Thermal comfort according to change of time enters by uncomfortable area gradually at general cold room temperature that magnetic pole is in human body. However, can know that keep continuous thermal comfort in case raise temperature in human body adaptation visual point. Experiments were performed in environmental chamber. Subjects were selected 4 men and 4 women whose life cycle were proved that are similar. The subjects stay in the pretesting room during the 30 minutes and enter the testing room under each experiment conditions. During the experiment, brain wave, electrocardiogram, blood pressure and thermal comfort and sensation responses were measured. In this study, physiological and psychological responses correspond under temperature raising at human body adaptation.

A survival prediction model of hemorrhagic shock in rats using a logistic regression equation (출혈성 쇼크를 일으킨 흰쥐에서 로지스틱 회귀분석을 이용한 생존율 예측)

  • Lee, Tak-Hyung;Lee, Ju-Hyung;Chung, Sang-Won;Kim, Deok-Won
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.132-134
    • /
    • 2009
  • Hemorrhagic shock is a common cause of death in emergency rooms. Since the symptoms of hemorrhagic shock occur after shock has considerably progressed, it is difficult to diagnose shock early. The purpose of this study was to improve early diagnosis of hemorrhagic shock using a survival prediction model in rats. We measured ECG, blood pressure, respiration and temperature in 45 Sprague-Dawley rats, and then obtained a logistic regression equation predicting survival rates. Area under the ROC curves was 0.99. The Hosmer-Lemeshow goodness-of-fit chi-square was 0.86(degree of freedom=8, p=0.999). Applying the determined optimal boundary value of 0.25, the accuracy of survival prediction was 94.7%

  • PDF

Magnetic-plethysmograph system development for real-time blood pressure estimate (실시간 혈압 추정을 위한 자계용적맥파 시스템 개발)

  • Kang, Seung-Jin;Lee, Kang-Hwi;Lee, Young-Jae;Kim, Kyeung-Nam;Lee, Jeong-Whan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1401-1402
    • /
    • 2015
  • 급작스레 발병하는 혈관 질환으로 인해 실시간 혈압 추정 연구가 많이 진행되어지고 있다. 본 논문에서는 자기장을 이용하여 혈압을 추정할 수 있는 자계용적맥파 시스템을 개발하였다. 자기장을 이용한 방법은 온도에 강하며 혈류와 상관성이 있기에 사용하였다. 혈압 추정의 과정은 총 3부분 나눌 수 있다. MPG측정, ECG측정 그리고 신호처리 부분이며 신호처리는 PC에서 디지털 필터링 및 PTT 계산을 실시하게 된다. 비교 기준 혈압으로 Omron 혈압계를 사용하여 동시 측정하였으며 결과로 각 PTT간 기준 수축기 및 이완기 혈압을 비교 할 수 있었다.

  • PDF

An effective transmission in high quality multimedia based emergency telemedicine (응급 원격진료시스템을 위한 고품질 멀티미디어 데이터의 무선망에서의 효율적 전송)

  • Park, Jung-Hoon;Park, Jin-Bae;Yoon, Tae-Sung;Yoo, Sun-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2343-2345
    • /
    • 2003
  • 근래에 여러 종류의 다양한 원격응급진료시스템이 개발되어 왔고, 그중 무선원격진료시스템에 있어서는 환자기록데이터나 생체신호, 정지영상과 같은 미미한 데이터만을 보내는 시스템이 주류였다. 이에 무선응급진료시스템에 많은 시도가 이루어지기 시작하였고, 다양한 형태의 시스템이 특정목적에 맞게 구현 되기 시작하였다. 본 논문에서는 고품질 멀티미디어 데이터를 원격응급진료시스템에 적용하여, 고품질 영상데이터와 ECG(Electro Cardiogram), SPO2, BP(Blood Pressure), Body Temperature 데이터를 CDMA 무선망을 이용하여 효과적으로 전송하는 방법을 제안한다. 또한 다양한 시험을 통하여 고품질 환자동영상과 환자데이터를 효과적으로 전송할 수 있음을 확인하였다.

  • PDF

Long-term measurement of physiological cardiovascular parameters using telemetry system in dosgs.

  • Kim, Eun-Joo;Seo, Joung-Wook;Choi, Gyu-Kap;Park, Eun-Kyung;Kim, Ki-Suk;Shin, Won-Ho;Han, Sang-Seop
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.87.1-87.1
    • /
    • 2003
  • With the issuance of the ICH “Guidance for industry S7A Safety Pharmacology Studies For Human Pharmaceuticals” in July 2001 came the preference for the use of unanesthetized animals when evaluation the safety profile of new pharmaceutical agents. Telemetry provides a means of obtaining measurements of physiological functions in conscious animals without the problems associated with classical cardiovascular measuring methods. The Korea Institute of Toxicology (KIT) established the telemetric measurement of cardiovascular parameters, such as Blood pressure, Heart rate, ECG (PR, RR, QRS, QT and QTcB interval) under GLP conditions. (omitted)

  • PDF

Safety pharmacology study of AS2-006A, a new wound healing drug

  • Kim, Hyun-Jin;Choi, Kyu-Gap;Yoon, Mi-Ran;Do, Sun-Hee;Kim, Eun-Joo;Cha, Kyung-Hoi
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.287.2-287.2
    • /
    • 2002
  • The safety pharmacological core battery studies of AS2-006A. a newly developed wound healing drug, were investigated according to the ICH S7A guidelines in compliance with Good Laboratory Practice(GLP) Regulations, The doses given were 0, 100. 300 and 1000 mg/kg and drugs were administered subcutaneously. The animals used for this study were mice, rats and guinea pigs. AS2-006A showed no effects on the central nervous system such as motor activity. behaviotal changes. coordination, sensory/motor reflex responses and body temperature. no effects on blood pressure(BP). heart rate(HR), and ECG profiles and respiratory system. it was concluded that AS2-006A possess no general pharmacological effects at all doses tested. (omitted)

  • PDF

General Pharmacology of CJ-50005 (Hepatitis A Vaccine) (A형 간염 예방백신 CJ-50005의 일반약리작용)

  • 김영훈;최재묵;정성학;정용주;이성희;김의경;김제학;박병훈
    • Biomolecules & Therapeutics
    • /
    • v.7 no.4
    • /
    • pp.390-396
    • /
    • 1999
  • CJ-50005 is a hepatitis A vaccine which is prepared by formalin inactivation of the HM175 virus cultured in human diploid MRC-5 cells. The general pharmacological properties of CJ-50005 were evaluated in various animals and in vitor system. CJ-50005 at the doses of 0.025, 0.25 and 0.75 $\mu\textrm{g}$/kg, i.m. had no effect on general behavior in mice, chemo- and electro-convulsions in mice, writhing syndrome induced by acetic acid in mice, the barbital sleeping time in mice, body temperature in rats, charcoal meal propulsion in mice and urine and electrolytes excretion in rats. In anesthetized dogs, CJ-50005(0.25 and 0.75 $\mu\textrm{g}$/kg, i.v) did not alter the respiratory rate, blood pressure, heart rate, femoral blood flow and ECG. In in vitro experiment, CJ-50005 at the concentration up to 0.02 $\mu\textrm{g}$/ml did not produce any changes in the contractions of the isolated ileum of guinea pigs caused by acetylcholine, histamine or $BaCl_2$. Since these pharmacological effects of CJ-50005 were observed at dose much greater than those in clinical use (approximately 0.025 $\mu\textrm{g}$/kg, i.m.), it is likely that this vaccine may be relatively free of undesirable effects in clinical practice.

  • PDF

Preliminary study on physiological changes of hemorrhagic shock in rats (백서에서의 출혈성 쇼크로 인한 생리 변화에 관한 예비 연구)

  • Lee, Ju-Hyung;Kim, Soo-Chan;Lee, Tak-Hyung;Chung, Sang-Won;Kim, Deok-Won
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1075-1076
    • /
    • 2008
  • Hemorrhagic shock is a common cause of death in emergency rooms. The objective evaluation of hemorrhagic shock is very important for early diagnosis and treatment. The purpose of this study is to understand its mechanism by analyzing the changes of bio-signals in hemorrhagic shock using controlled hemorrhage of SD rats. In this study, we constructed a hemorrhagic integrated system to control bleeding and to simultaneously measure bio-signals such as ECG, blood pressure, temperature, and respiration. In order to verify the system, we measured the bio-signals mentioned above while hemorrhagic shock was induced by withdrawing blood (2.5ml/100g/15min) from a femoral vein for 10 rats.

  • PDF

Monitoring system of blood pressure change according to PTT based posture (PTT기반 자세에 따른 혈압변화 모니터링 시스템)

  • Kim, Mi-Seong;Noh, Yun-Hong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.534-535
    • /
    • 2017
  • With the economic growth, the quality of life of the individual is improving and interest in health is increasing. However, it is not easy for self-care for the modern people who are busy and the elderly who are uncomfortable. The purpose of this study was to develop a healthcare system that can more easily monitor the health condition of the patients. The ECG and pulse wave including the important health information that can be conveniently measured by the general public can be measured and the PTT and to monitor the health status of the circulatory system. To evaluate the performance of the implemented system, we measured PTT according to posture change and evaluated the possibility of monitoring arterial blood flow during daily life.

  • PDF