• Title/Summary/Keyword: ECG analysis system

Search Result 170, Processing Time 0.027 seconds

Real-Time QRS Detection Using Wavelet Packet Transform

  • Bholsithi, Wisarut;;Hinjit, Watcharapong;Dejhan, Kobchai
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1880-1884
    • /
    • 2004
  • The wavelet packet transform has been applied for QRS detection with squaring, window integration, and impulse filter techniques to cut down the false detection of QRS complex. This real time QRS detection has been performed on Simulink and Matlab. The correct QRS detection rates have reached to 99.75% in the experiment with 15 sets of ECG data from European ST-T database which are kept in Physionet.

  • PDF

A Study of Biosignal Analysis System for Sensibility Evaluation (감성을 평가하기 위한 생체신호 분석 시스템에 관한 연구)

  • Lee, Ji-Hyeoung;Kim, Kyung-Ho
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.35-38
    • /
    • 2010
  • 본 논문에서는 일상생활 속에서 무자각적으로 생체신호를 측정하고 분석하여 감성을 평가할 수 있는 임베디드 시스템에 관하여 연구하였다. 지속적으로 변화하는 감성을 일관적이며 신뢰성이 높은 생리적인 방법으로 평가하기 위해 심전도(ECG:Electrocardiogram), 맥파(PPG:Photoplethysmogram)의 두 가지 생체신호를 측정하고, 무선전송(Bluetooth) 장치를 이용하여 측정한 생체신호를 실시간으로 노트북PC로 전송하여 분석하였다. 생체신호의 분석방법은 FFT(Fast Fourier Transform)과 전력스펙트럼밀도(Power Spectrum Density)를 이용한 주파수 분석방법으로 두 생체신호의 특정 주파수 대역이 가지는 자율신경계의 활성도의 비율을 분석하여 비교 연구하였다. 또한 보다 빠르고 정확한 감성을 평가하기 위하여 분석알고리즘의 연산을 최소화 하였으며 그래프를 이용한 분석결과의 시각화를 하였다. 본 논문에서는 무자각적인 생체신호 측정 시스템을 이용하여 다양한 상황에서 생체신호를 측정하고, 개발한 분석 알고리즘으로 분석한 결과의 차이를 연구하여 정확도 및 신뢰도를 기준으로 감성을 평가하기 위한 분석 시스템을 평가하였다.

  • PDF

A Study of Fast Data Transmission System for Unrestricted Holter ECG Using Zero-Configuration (Zero-Configuration을 이용한 무구속 Holter 심전도 데이터 고속 전송 시스템에 관한 연구)

  • Lee, Kwang-Hyun;Yim, Jun-Woo;Kim, Young-Kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.2
    • /
    • pp.479-484
    • /
    • 2010
  • Researches of Healthcare have been fulfilled lively with an advanced age and change of lifestyles. Especially, medical field has focused on researches of Healthcare due to that reasons. The Healthcare service requires the foundation technologies, such as sensor aggregating, data saving and data transmitting/analysis. In this research, we proposed the unrestricted equipment which can save a lot of aggregated patient's medical data to guarantee the patient's movement in Healthcare service. Moreover, we research the method which can transmit the aggregated data as soon as possible. Also, we implemented the system which can transmit the patient's medical data automatically for convenient use.

Pulse Diagnosis Algorithm and Digital Filter Design for Development of Digital Biomedical System (전자 맥진기 시스템 개발을 위한 맥파분석 알고리즘과 디지털 필터 설계)

  • Kim, Sang-Ho;Lim, Duk-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4473-4482
    • /
    • 2010
  • The examination of pulse, which is a typical palpation technique in the oriental medicine, has been used conventional analog system for discrimination of 28 pulses. However, the clipping phenomenon in the pulses, which used same feature extraction technique with ECG signals, has been occurred in analog system due to feature extraction method and over amplification from the input signals. It caused inaccurate to analyze the pulse signals. In this paper, we propose a digital filter design technique based on Prony's method for signal modeling and C-spline interpolation for feature extraction from pulse signal to compensate analog pulse detection system. In addition, we suggest a compensated electronic pulse detection system comprising new pulse analyzing algorithm and shape analysis technique for pulses, which were difficult to use in analog system. The feasibility for new proposed system has been confirmed comparing output signals between electronic pulse detection system having proposed filter design techniques with pulse analyzing algorithm and conventional analog system.

Design of The Patient Monitoring System based on Wearable Device for Multi-biosignal Measurement (다중 생체신호 측정 웨어러블 디바이스 기반 환자 모니터링 시스템 설계)

  • Lee, Minhye;Chung, Gisoo;Jeong, Dongmyong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.103-109
    • /
    • 2017
  • In order to apply the patient monitoring system to the hospital field, it is necessary to be able to measure and analysis data the major bio-signals that are basically covered by the existing patient monitoring system. We have implemented a wearable device and the patient monitoring system for measuring ECG and oxygen saturation. The implemented system transmits the measured bio-signal to the server on the nursing station via Bluetooth. It is represented by graph waveforms and numerical values that can be checked by the medical staff in the patient monitoring system. The validity of this system is verified by comparing the data collected through the designed system with the data obtained from the conventional equipment.

Implementation of the Multi-channel Vital Signal Monitoring System for Home Healthcare (홈 헬스케어를 위한 다채널 생체신호 모니터링 시스템 구현)

  • Youn, Jeong-Yun;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.3
    • /
    • pp.197-202
    • /
    • 2010
  • In this paper, multi-channel vital signal monitoring system was implemented for home healthcare. The system able to measure vital signal for example ECG, PPG and temperature simultaneously at patients’ home. The vital signal is an essential parameter for healthcare application and can be easily extracted from patients. The implemented system consist of sensor parts for signal extraction, signal amplifier and filter for analog circuit, analog signal to digital conversion for controlling devices and lastly the monitoring program. The system able to transmit vital signals using Bluetooth wireless communications to personal computer or home server. And the tele-monitoring system able to display real-time signals using web monitoring program. In medical application, the vital signal parameter able to stored and saved in the web server for further medical analysis. This system opens up the possibilities of ubiquitous healthcare where further implementation can be easily done.

Development of Data Acquisition System for Quantification of Autonomic Nervous System Activity and It's Clinical Use (자율신경계의 활성도 측정을 위한 Data Acquisition System의 개발 및 임상응용)

  • Shin, Dong-Gu;Park, Jong-Sun;Kim, Young-Jo;Shim, Bong-Sup;Lee, Sang-Hak;Lee, Jun-Ha
    • Journal of Yeungnam Medical Science
    • /
    • v.18 no.1
    • /
    • pp.39-50
    • /
    • 2001
  • Background: Power spectrum analysis method is a powerful noninvasive tool for quantifying autonomic nervous system activity. In this paper, we developed a data acquistion system for estimating the activity of the autonomic nervous system by the analysis of heart rate and respiratory rate variability using power spectrum analysis. Materials and methods: For the detection of QRS peak and measurement of respiratory rate from patient's ECG, we used low-pass filter and impedence method respectively. This system adopt an isolated power for patient's safety. In this system, two output signals can be obtained: R-R interval heart rate) and respiration rate time series. Experimental ranges are 30-240 BPM for ECG and 15-80 BPM for respiration. Results: The system can acquire two signals accurately both in the experimental test using simulator and in real clinical setting. Conclusion: The system developed in this paper is efficient for the acquisition of heart rate and respiration signals. This system will play a role in research area for improving our understanding of the pathophysiologic involvement of the autonomic nervous system in various disease states.

  • PDF

The Portable arrhythmia monitor (휴대용 부정맥 모니터에 관한 연구)

  • An, Jae-Bong;Sin, Ho-Yong;Jeong, Hyeok-Gu;Kim, Yong-Man;Lee, Myeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1986.07a
    • /
    • pp.209-211
    • /
    • 1986
  • This paper describes the design of portable arrhythmia monitor and associated algorithm for automated diagnosis based-on micro-computer in the ambulatory ECG recording, analysis, and transmitting to a hospital host computer immediately through the telephone system.

  • PDF

CHAOTIC ANALYSIS OF PR INTERVAL VARIABILITY IN PARASYMPATHETIC STIMULATION (부교감신경의 자극에서 나타나는 PR구간의 변동량에 대한 혼돈 분석)

  • Lee, Jong-Min;Park, Kwang-Suk;Yum, Mung-Gul
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.205-208
    • /
    • 1995
  • Analysis of Heart Rate Variability has been studied to estimate autonomic nervous system. PR interval represents conduction time from atrium to ventricle. PR interval variability(PRV) is also can be used to estimate autonomic nervous system. We have acquired two-state ECGs of children who are before vagal stimulation and after vagal stimulation. We applied chaotic theory to each ECG in order to analyze PRV, and compared the results from frequency domain analysis. The correlation dimension of PRV of pre-stimulated children is higher than that of post-stimulated children.

  • PDF

Evaluation of the Ambient Temperature Effect for the Autonomic Nervous Activity of the Young Adult through the Frequency Analysis of the Heart Rate Variability (심박변이율 주파수 분석을 통한 실내온도에 따른 건강한 성인의 자율신경계 활동 평가)

  • Shin, Hangsik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1240-1245
    • /
    • 2015
  • The purpose of this paper is to investigate the autonomic nervous system activity in various ambient temperatures. To evaluate autonomic function, we use the frequency domain analysis of heart rate variability such as FFT(fast fourier transformation), AR(Auto-Regressive) model and Lomb-Scargle peridogram. HRV(heart rate variability) is calculated by using ECG recorded from 3 different temperature room which temperature is controlled in 18℃(low), 25℃(mid) and 38℃(high), respectively. Totally 22 subjects were participated in the experiment. In the results, the most significant autonomic changes caused by temperature load were found in the HF(high frequency) component of FFT and AR model. And the HF power is decreased by increasing temperature. Significance level was increased by increasing the difference of temperatures.