• Title/Summary/Keyword: ECG Analysis

Search Result 379, Processing Time 0.023 seconds

Analyzing Heart Rate Variability for Automatic Sleep Stage Classification (수면단계 자동분류를 위한 심박동변이도 분석)

  • 김원식;김교헌;박세진;신재우;윤영로
    • Science of Emotion and Sensibility
    • /
    • v.6 no.4
    • /
    • pp.9-14
    • /
    • 2003
  • Sleep stages have been useful indicator to check a person's comfortableness in a sleep, But the traditional method of scoring sleep stages with polysomnography based on the integrated analysis of the electroencephalogram(EEG), electrooculogram(EOG), electrocardiogram(ECG), and electromyogram(EMG) is too restrictive to take a comfortable sleep for the participants, While the sympathetic nervous system is predominant during a wakefulness, the parasympathetic nervous system is more active during a sleep, Cardiovascular function is controlled by this autonomic nervous system, So, we have interpreted the heart rate variability(HRV) among sleep stages to find a simple method of classifying sleep stages, Six healthy male college students participated, and 12 night sleeps were recorded in this research, Sleep stages based on the "Standard scoring system for sleep stage" were automatically classified with polysomnograph by measuring EEG, EOG, ECG, and EMG(chin and leg) for the six participants during sleeping, To extract only the ECG signals from the polysomnograph and to interpret the HRV, a Sleep Data Acquisition/Analysis System was devised in this research, The power spectrum of HRV was divided into three ranges; low frequency(LF), medium frequency(MF), and high frequency(HF), It showed that, the LF/HF ratio of the Stage W(Wakefulness) was 325% higher than that of the Stage 2(p<.05), 628% higher than that of the Stage 3(p<.001), and 800% higher than that of the Stage 4(p<.001), Moreover, this ratio of the Stage 4 was 427% lower than that of the Stage REM (rapid eye movement) (p<.05) and 418% lower than that of the Stage l(p<.05), respectively, It was observed that the LF/HF ratio decreased monotonously as the sleep stage changes from the Stage W, Stage REM, Stage 1, Stage 2, Stage 3, to Stage 4, While the difference of the MF/(LF+HF) ratio among sleep Stages was not significant, it was higher in the Stage REM and Stage 3 than that of in the other sleep stages in view of descriptive statistic analysis for the sample group.

  • PDF

A Study of Biosignal Analysis System for Sensibility Evaluation (감성을 평가하기 위한 생체신호 분석 시스템에 관한 연구)

  • Lee, Ji-Hyeoung;Kim, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.12
    • /
    • pp.19-26
    • /
    • 2010
  • In this paper, we studied about the Embedded System of the biosignal measurement and analysis to sensibility evaluation in daily life for non-intrusive. This system is two kinds of measuring biosiganls(Electrocardiogram:ECG, Photoplethysmography:PPG) and analyzed by real-time wireless transmission to notebook PC using bluetooth for consistent and reliability of physiological way to assess continuously changing sensibility. Comparative studied of an autonomic nerve system activity ratio on characteristics frequency band of two kinds of biosignal analyzed frequency way using the Fast Fourier Transform(FFT) and Power Spectrum Density(PSD). Also the key idea of this system is to minimize computing of analysis algorithm for faster and more accurate to assess the sensibility, and the result of the visualization using graph. In this paper, we evaluated the analysis system to assess sensibility that measuring various situation in daily life using a non-intrusive biosignal measurement system, and the accuracy and reliability in comparison with difference of result by development analysis system.

The Prognostic role of Electrocardiographic Signs of Cor Pulmonale in Chronic Obstructive Pulmonary Disease (폐성심을 시사하는 심전도 소견 유.무에 따른 만성폐쇄성 폐질환 환자의 예후)

  • Shin, Moo-Chul;Park, Jae-Yong;Bae, Moon-Seob;Bae, Nack-Cheon;Chae, Po-Hee;Kim, Chang-Ho;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.944-955
    • /
    • 2000
  • Background : In patients with chronic obstructive pulmonary disease(COPD), several factors have been associated with a poor prognosis. These include old age, low $FEV_1$ low diffusing capacity, high alveolar-arterial oxygen pressure difference, and finally cor pulmonale. This study was done to investigate if the ECG signs suggesting cor pulmonale were independent prognostic factors in patients with COPD. Method : We analyzed ECG, pulmonary function data and arterial blood gas values in 61 patients who were admitted through the emergency department with an acute exacerbation of COPD. The ECG signs reflecting cor pulmonale were right strial overloading(RAO), right bundle branch block, right ventricular hypertrophy and low-voltage QRS. The 61 patients were divided into 2 groups ; group I with no ECG signs(n=36) and group II with one or more ECG signs(n=25) suggesting cor, pulmonale. Results : Poor, prognostic factors by univariate analysis were low $FEV_1$, $FEV_1$ % pred., VC % pred., DLco, DLco % pred., $PaO_2$ and $SaO_2$ high $PaCO_2$ presence of ECG signs reflecting cor pulmonale, presence of mental status change, use of mechanical ventilator, and long term use of glucocorticoid. A multivariate analysis indicated that age(risk ratio=1.13, 95% confidence interval 1.05-1.23), DLco % pred. (risk ratio=0,97. 95% confidence interval 0.94-0.99), $PaO_2$ (risk ratio=0.95, 95% confidence interval 0.90-0.99) and RAO(risk ratio=5.27, 95% confidence interval 1.40-19.85) were independent prognostic factors of survival. There was a significant difference in survival between the patients with and without RAO(p=0.038). The survival rates at 1, 2, and 5 years were 94.5%. 81.4%, and 50.0% in patients without RAO and 82.4%, 70.6%, and 27.5% in patients with RAO, respectively. Conclusion : These results suggest that the presence of ECG signs reflecting cor pulmonale is a predictor of survival and that RAO of these ECG signs is a significant independent predictor of survival in patients with COPD.

  • PDF

A development of measuring system for Autonomic Nervous Activity (자율신경계 활성도 측정 시스템 개발)

  • 이준하
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.141-146
    • /
    • 2000
  • Power spectrum analysis is a powerful noninvasive tool for quantifying autonomic nervous system activity. In this paper, We developed a measuring system for Autonomic Nervous Activity by using power spectrum analysis method to obtain the activities of autonomic nervous system. This system adopt a isolated power for patient's safety. In this system, Two output signal is obtained - R-R interval time variability and Respiration time variability. Time variability is use to find out some disease related to Autonomic Nervous System. Experimental tested range is 30 ~ 240 BPM for ECG and 15~80 BPM for Respiration.

  • PDF

Analysis of Electroencephalogram and Electrocardiogram at an Acupoint PC9 during Pulsed Magnetic Field Stimulus

  • Lee, Jin-Yong;Hwang, Do-Gwen;Yoo, Jun-Sang;Lee, Hyun-Sook
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.133-137
    • /
    • 2012
  • We investigated the effects of pulsed magnetic fields (PMF) stimulus on electroencephalogram (EEG) alpha activity and heart rate variability (HRV) from electrocardiogram (ECG) measurements with various stimulus durations at acupoint PC9. The alpha activity in the EEG and the ratio of low frequency power and high frequency power (LHR) in the HRV, a reflection of sympathovagal activity, were increased and decreased, respectively, after PMF stimulus of 3 min. Our spectral analysis quantitatively proved that the changes in the EEG alpha activity were consistent with an autonomic function in the ECG. These findings suggest that appropriate PMF stimulus results in the same effect as that of acupuncture applied to the acupoint PC9, which is closely related to the parasympathetic activity of the autonomic nervous system.

Sleep Stage Analysis of Obstructive Sleep Apnea Patient using HRV (HRV을 이용한 폐쇄성 수면 무호흡 환자의 수면 단계 분석)

  • Ye, Soo-Young;Eom, Sang-Hee;Jeon, Gye-Rok
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.464-467
    • /
    • 1997
  • In this study, ECG was recorded during sleep patients with obstructive sleep apnea. We detecte(heart rate variability) signal from the ECG wa QRS detection algorithm. And we observed HRV by the power spectrum density using autoregr modeling. The experimental results were analysis sleep stage 1, sleep stage 2, sleep stage 3, sleep s sleep stage REM. In experimental result, the PSD with obstructive sleep apnea patients was distributed low frequency band except sleep step 4. These effect means that the sympathetic nervous system affected the sleep stage 1, 2, REM and the parasympathetic nervous system affected the sleep stage 3, 4 with obstructive sleep apnea patients.

  • PDF

Non-intrusive measurement of pulse arrival time and Estimation of Systolic Blood Pressure (무구속적 맥파 전달 시간의 측정을 통한 혈압 추정)

  • Chee, Young-Joon;Park, Kwang-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.489-492
    • /
    • 2005
  • Even though the blood pressure is one of the most widely used index for the healthcare monitoring of hypertensive and normotensive persons, there is no non-intrusive measurement method which is commercialized until now. Pulse Arrival Time (PAT) is known that it has close relation with the systolic blood pressure (SBP) and arterial stiffness. In this study, SBP estimation methods by non-intrusive measurement of PAT are suggested. For the unconstrained measurement of PAT, the first method used the electrically non contact electrocardiogram (ENC-ECG) technique and the reflective type of Photoplethysmography (PPG) sensor on the computer mouse. In the second method, ENC-ECG and the air pressure sensor in the seat cushion on a chair were measured. The third method used ECG electrodes and PPG sensors on the toilet seat cover. The validation and regression analysis of the relationship of PAT and SBP are summarized. These methods have considerable errors to be used for all people. But these can be applied for each subject after the parameter customization within acceptable error. So, it is feasible for suggested methods to be used for monitoring of SBP in daily life in non-intrusive way when there is personal identification system of each subject.

  • PDF

P-Waves and T-Wave Detection Algorithm in the ECG Signals Using Step-by-Step Baseline Alignment (단계별 기저선 정렬을 이용한 ECG 신호에서 P파와 T파 검출 알고리즘)

  • Kim, Jeong-Hong;Lee, SeungMin;Park, Kil-Houm
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.6
    • /
    • pp.1034-1042
    • /
    • 2016
  • The detection of P-waves and T-wave in the electrocardiogram signal analysis is an important issue. But the accuracy of the boundary detection algorithm is an insufficient level in the change of slow transition in the signal compared to the QRS complex. This study proposes an algorithm to detect P-wave and T-wave sequentially after determining local baseline using QRS complex. First, we detected the peak points based on local baseline and determined the onset and offset through the calculation of the area of the section. After modifying the baseline using detected waveform, we detected the other waveform in the same way and separated the P-wave and the T-wave based on the location. We used the PhysioNet QT database to evaluate the performances of the algorithm, and calculate the mean and the standard deviations. The experiment results show that standard deviations are under the tolerances accepted by expert physicians, and outperform the results obtained by the other algorithms.

A Study on a Stress Measurement Algorithm Based on ECG Analysis of NUI-applied Tangible Game Users (NUI가 적용된 체감형 게임의 사용자 심전도 분석에 의한 스트레스 측정 알고리즘 연구)

  • Lee, Hyun-Ju;Shin, Dong-Il;Shin, Dong-Kyoo
    • Journal of Korea Game Society
    • /
    • v.13 no.5
    • /
    • pp.73-80
    • /
    • 2013
  • NUI(Natural User Interface) allows users to directly interact with surrounding digital devices using their voices or body motions without additional input/output interface devices. Our study has been carried out on human users who play a tangible game with body motions in the NUI-applied smart space. ECG was measured for 60 seconds duration before and after playing the game to determine user stress levels, and the measured signals were analyzed through an improved Random Forest algorithm. In order to experiment by a supervised learning, users additionally input whether or not the user felt stress. Moreover, the improved algorithm showed 1.04% higher accuracy than existing algorithm.

Improved Dynamic Programming in Local Linear Approximation Based on a Template in a Lightweight ECG Signal-Processing Edge Device

  • Lee, Seungmin;Park, Daejin
    • Journal of Information Processing Systems
    • /
    • v.18 no.1
    • /
    • pp.97-114
    • /
    • 2022
  • Interest is increasing in electrocardiogram (ECG) signal analysis for embedded devices, creating the need to develop an algorithm suitable for a low-power, low-memory embedded device. Linear approximation of the ECG signal facilitates the detection of fiducial points by expressing the signal as a small number of vertices. However, dynamic programming, a global optimization method used for linear approximation, has the disadvantage of high complexity using memoization. In this paper, the calculation area and memory usage are improved using a linear approximated template. The proposed algorithm reduces the calculation area required for dynamic programming through local optimization around the vertices of the template. In addition, it minimizes the storage space required by expressing the time information using the error from the vertices of the template, which is more compact than the time difference between vertices. When the length of the signal is L, the number of vertices is N, and the margin tolerance is M, the spatial complexity improves from O(NL) to O(NM). In our experiment, the linear approximation processing time was 12.45 times faster, from 18.18 ms to 1.46 ms on average, for each beat. The quality distribution of the percentage root mean square difference confirms that the proposed algorithm is a stable approximation.