• Title/Summary/Keyword: EAF′s dusts, millscale

Search Result 1, Processing Time 0.018 seconds

A Study on Reduction Treatment of EAF′s Dusts Mixed with Millscale (電氣爐製鋼粉塵과 millscale 混合펠릿의 還元擧動에 관한 硏究)

  • 윤기병
    • Resources Recycling
    • /
    • v.9 no.6
    • /
    • pp.45-52
    • /
    • 2000
  • Generally, the residues of EAF's dusts treated by reduction process at high temperature are disposed. If the residues can be recycled as iron sources of EAF by upgrading their iron contents, it can be expected to reduce the amounts of disposed wastes and the environmental impacts. Reduction of EAF's dusts mixed with millscale was carried out in rotary hearth furnace to upgrade iron contents of reduction residues. Dusts should be reduced rapidly to protect from reoxidation of reduced iron residue which can be reoxidized at high temperature. In our experimental conditions, optimum reduction time was about 40min. and iron contents of the residues were increased with increasing mixing ratio of millscale and upgrade to 85% at 50%wt mixing ratio. Zinc and lead contents in residues were about 3% and 0.5% respectively. The residues reduced rapidly must be recycled in EAF because heavy metal elements in the residues can be extracted easily and contaminate air and water.