• Title/Summary/Keyword: EA performance

Search Result 132, Processing Time 0.028 seconds

Optimal Designs for the Experiments related with Marine Environment (해양환경에 관련된 실험을 위한 최적실험계획)

  • 김재환
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.3 no.2
    • /
    • pp.93-103
    • /
    • 1997
  • This paper develops a new heuristic, the Excursion Algorithm(EA), for constructing optimal designs for the experiments related with marine environment. The proposed EA consists of three parts: 1) construction of an initial feasible solution, 2) excursions over a bounded region, and 3) stopping rules. It is the second part that distinguishes the EA from the other existing heuristic methods. It turns out that excursions over a bounded feasible and/or infeasible region is effective in alleviating the risks of being trapped at a local optimum. Since this problem is formulated for the first time thesis, other heuristic algorithms do not exist. Therefore, global optimal solutions are obtained by complete enumeration for some cases, and the performance of the EA is evaluated in terms of solution quality. Computational results show that the proposed EA is effective in finding good(or, in many cases, global) solutions to the constrained optimal experimental design problems.

  • PDF

Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant (원자력발전소 직류전원계통용 축전지 성능시험 분석)

  • Kim, Daesik;Cha, Hanju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.

Effects of Information from Enterprise Architecture on Government IT Projects (EA(Enterprise Architecture)에서 제공하는 정보가 공공기관 정보화사업수행 활동에 미치는 영향 연구: 관세청 정보화 구축·운영사업 사례를 중심으로)

  • Hyun, Myungjin;Kim, Miryang
    • Informatization Policy
    • /
    • v.29 no.3
    • /
    • pp.61-81
    • /
    • 2022
  • This paper explores how the provided information from Enterprise Architecture (EA) affects the activities to for performing IT projects. The IT projects analyzed in this paper are projects to for developing and maintaining Korea Customs' UNI-PASS. This research was conducted based on surveys to demonstrate the effects of the information from EA on activities for IT projects. Information from EA is categorized into propriety, sufficiency and consistency. Activities for IT projects are defined as management, participation, communication, requirement management and human resource. Correlational analysis is used to measure the effects of the inf ormation on the defined activities. The analysis, which verifies the provided information by EA, does not have meaningful correlation with project management nor human resource. For public officials in charge, Sufficiency of the information produces a positive effect on decision making. For operation company, consistency of the information encourages utilization of the resources required for the project. This research suggests that strategies for performing IT projects with EA information that can support the verification of characteristic environments of each project and performance of vital activities required by the participants' roles will ensure the success of government IT projects.

Comparison of Nitrate and Fluoride Removals between Reverse-Osmosis, Nano-Flitration, Electro-Adsorption, Elecero-Coagulation in Small Water Treatment Plants (소규모 수도시설의 역삼투(RO), 나노여과(NF), 전기흡착(EA), 전기응집(EC) 공정의 질산성 질소 및 불소 이온 제거 성능 비교)

  • Han, Song-Hee;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.2027-2036
    • /
    • 2013
  • Comparison of removal performance between reverse osmosis(RO), nanofiltration(NF), electrocoagulation(EC) and electroadsorption(EA) for removal of nitrate and fluoride often exceeded the limits of water quality in small water treatment plants. Removals of nitrate and fluoride were 72-92% and 74-85% in RO, 5-15% and 1% in NF, 99% and 44% in EA equipped with MWCNT coated electrodes, 82% and 77% in EA equipped with Cu-MWCNT electrodes, and 11-46% and 69-99% in EC. Consequently, high removals of both ions were anticipated in RO. Effective removal of both ions are possible for EC, but great production of sludge is a big burden. EA equipped with the MWCNT electrodes showed a great fluctuation in removal efficiency, and electrode stability should be upgraded.

EA-based Tuning of a PID Controller with an Anti-windup Scheme (안티와인드업 기법을 가지는 PID 제어기의 EA 기반 동조)

  • Jin, Gang-Gyoo;Park, Dong-Jin
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.10
    • /
    • pp.867-872
    • /
    • 2013
  • Many practical processes in industry have nonlinearities of some forms. One commonly encountered form is actuator saturation which can cause a detrimental effect known as integrator windup. Therefore, a strategy of attenuating the effects of integrator windup is required to guarantee the stability and performance of the overall control system. In this paper, optimal tuning of a PID (Proportional-Integral-Derivative) controller with an anti-windup scheme is presented to enhance the tracking performance of the PID control system in the presence of the actuator saturation. First, we investigate effective anti-windup schemes. Then, the parameters of both the PID controller and the anti-windup scheme are optimally tuned by an EA (Evolutionary Algorithm) such as the IAE (Integral of Absolute Error) is minimized. A set of simulation works on two high-order processes demonstrates the benefit of the proposed method.

GE7EA Gas Turbine Combustion Performance Test of DME and Methane (DME와 메탄의 GE7EA 모사가스터빈 연소성능시험)

  • Lee, Min-Chul;Seo, Seok-Bin;Chung, Jae-Hwa;Joo, Youg-Jin;Ahn, Dal-Hong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3270-3275
    • /
    • 2007
  • DME (Dimethyl Ether, $CH_3OCH_3$) has highly attracted attention as an alternative fuel for transportation, power generation and LPG substitute owing to its easy transportation and cleanliness. This study was conducted to verify the combustion performance and to identify potential problems when DME is fuelled to a gas turbine. GE7EA gas turbine of Pyong-Tak power plant was selected as a target to apply the DME. Combustion tests were conducted by comparing DME with methane, which is a major component of natural gas, in terms of combustion instability, $NO_X$ and CO emissions, and the outlet temperature of the combustion chamber. The results of the performance tests show that DME is very clean but has a low combustion efficiency in low load condition. From the results of the fuel nozzle temperature we have ascertained that DME is easy to flash back, and this property should be considered when operating a gas turbine and retrofitting a burner.

  • PDF

Overlapping Decentralized Robust EA Control Design for an Active Suspension System of a Full Car Model (전차량의 능동 현가장치 제어를 위한 중복 분산형 견실 고유구조 지정 제어기 설계)

  • Jung, Yong-Ha;Choi, Jae-Weon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.206-213
    • /
    • 2001
  • An overlapping decentralized robust EA(eigenstructure assignment) controller is designed for an active suspension system of a vehicle based on a full car model with 7-degree of freedom. Using overlapping decomposition, the full car model is decentralized by two half car models. For each half car model, an effective and disturbance suppressible controller can be obtained by assigning appropriately a left eigenstructure of the system. The performance of the proposed overlapping decentralized robust EA controller is compared with that of a conventional centralized EA controller through computer simulations.

  • PDF

A Study on the Risk Factors for Successful Enterprise Architecture Implementation (성공적인 전사적 아키텍처 구축을 위한 위험요인에 관한 연구)

  • Park, Byung-Sun;Kim, Hyun-Soo;Yang, Kyung-Sik
    • Journal of Information Technology Services
    • /
    • v.5 no.3
    • /
    • pp.1-23
    • /
    • 2006
  • Today, Organizations should be equipped with flexibility in order to cope with rapidly changing environment in management. By doing so, they are able to grow and obtain their superior competitiveness in highly developed economic arena. Recently, Enterprise Architecture is actively constructed to perform such a change flexibly. In this regard, it is crucial to figure out some risk factors for the organizations that place an order. Besides, it is also important to find out the quality of EA and some risk factors caused by the organizations that receive an order. Lastly, it is absolutely important to verify the relationship between such factors and outcomes of EA. In this aspect, this study will verify risk factors made by the former organizations and investigate the quality of EA and its outcome by proving the said relationship. In doing so, it will suggest an appropriate direction for the companies that will build up or perform EA successfully.

The development of highly functional paints improving NIR reflectance by investigating silica particles size for pigment mixing (안료배합용 실리카 입자사이즈에 따른 근적외선 반사율을 향상시킨 고기능성 도료 제조)

  • Eunseok Woo;Yunseok Noh;Jinho Lee;Yong-Wook Choi;Bora Kim
    • Journal of the Korean institute of surface engineering
    • /
    • v.57 no.2
    • /
    • pp.98-104
    • /
    • 2024
  • In order to overcome the urban heat island effect, highly functional paint is attracting attention as a promising means by shielding heat on the structure (building) surface. When a paint was prepared containing nano-sized silica particles, the heat-insulating performance was relatively higher than that of paints with other sizes. In addition, developed paints showed enhanced properties such as chemical resistance and abrasion resistance test because of the presence of nano-sized silica included in functional paint.

Shrinkage Reduction Performance of HPFRCC Using Expansive and Srhinkage Reducing Admixtures (팽창재와 수축저감제를 사용한 HPFRCC의 수축 저감 성능)

  • Park, Jung-Jun;Moon, Jae-Heum;Park, Jun-Hyoung;Lee, Jang-Hwa;Kim, Sung-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.34-40
    • /
    • 2014
  • High-performance fiber-reinforced cement composite (HPFRCC) shows very high autogenous shrinkage, because it contains a low water-to-binder ratio (W/B) of 0.2 and high fineness admixture without coarse aggregate. Thus, it needs a method to decrease the cracking potential. Accordingly, in this study, to effectively reduce the shrinkage of HPFRCC, a total of five different ratios of SRA (1% and 2%), EA (5% and 7.5%), and a combination of SRA and EA (1% and 7.5%) were considered. According to the test results of ring-test, a combination of SRA and EA (1% and 7.5%) showed best performance regarding restrained shrinkage behavior without significant deterioration of compressive and tensile strengths. This was also verified by performing modified drying shrinkage crack test.