• Title/Summary/Keyword: E-Magnetic Analysis

Search Result 335, Processing Time 0.022 seconds

Comparative analysis on darcy-forchheimer flow of 3-D MHD hybrid nanofluid (MoS2-Fe3O4/H2O) incorporating melting heat and mass transfer over a rotating disk with dufour and soret effects

  • A.M. Abd-Alla;Esraa N. Thabet;S.M.M.El-Kabeir;H. A. Hosham;Shimaa E. Waheed
    • Advances in nano research
    • /
    • v.16 no.4
    • /
    • pp.325-340
    • /
    • 2024
  • There are several novel uses for dispersing many nanoparticles into a conventional fluid, including dynamic sealing, damping, heat dissipation, microfluidics, and more. Therefore, melting heat and mass transfer characteristics of a 3-D MHD Hybrid Nanofluid flow over a rotating disc with presenting dufour and soret effects are assessed numerically in this study. In this instance, we investigated both ferric sulfate and molybdenum disulfide as nanoparticles suspended within base fluid water. The governing partial differential equations are transformed into linked higher-order non-linear ordinary differential equations by the local similarity transformation. The collection of these deduced equations is then resolved using a Chebyshev spectral collocation-based algorithm built into the Mathematica software. To demonstrate how different instances of hybrid/ nanofluid are impacted by changes in temperature, velocity, and the distribution of nanoparticle concentration, examples of graphical and numerical data are given. For many values of the material parameters, the computational findings are shown. Simulations conducted for different physical parameters in the model show that adding hybrid nanoparticle to the fluid mixture increases heat transfer in comparison to simple nanofluids. It has been identified that hybrid nanoparticles, as opposed to single-type nanoparticles, need to be taken into consideration to create an effective thermal system. Furthermore, porosity lowers the velocities of simple and hybrid nanofluids in both cases. Additionally, results show that the drag force from skin friction causes the nanoparticle fluid to travel more slowly than the hybrid nanoparticle fluid. The findings also demonstrate that suction factors like magnetic and porosity parameters, as well as nanoparticles, raise the skin friction coefficient. Furthermore, It indicates that the outcomes from different flow scenarios correlate and are in strong agreement with the findings from the published literature. Bar chart depictions are altered by changes in flow rates. Moreover, the results confirm doctors' views to prescribe hybrid nanoparticle and particle nanoparticle contents for achalasia patients and also those who suffer from esophageal stricture and tumors. The results of this study can also be applied to the energy generated by the melting disc surface, which has a variety of industrial uses. These include, but are not limited to, the preparation of semiconductor materials, the solidification of magma, the melting of permafrost, and the refreezing of frozen land.

Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder (무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법)

  • Yoon, Moon-Hyun;Sung, Mi-Sook;Yin, Chang-Sik;Lee, Heung-Kyu;Choe, Bo-Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.10 no.2
    • /
    • pp.98-107
    • /
    • 2006
  • Magnetization Transfer (MT) imaging generates contrast dependent on the phenomenon of magnetization exchange between free water proton and restricted proton in macromolecules. In biological materials in knee, MT or cross-relaxation is commonly modeled using two spin pools identified by their different T2 relaxation times. Two models for cross-relaxation emphasize the role of proton chemical exchange between protons of water and exchangeable protons on macromolecules, as well as through dipole-dipole interaction between the water and macromolecule protons. The most essential tool in medical image manipulation is the ability to adjust the contrast and intensity. Thus, it is desirable to adjust the contrast and intensity of an image interactively in the real time. The proton density (PD) and T2-weighted SE MR images allow the depiction of knee structures and can demonstrate defects and gross morphologic changes. The PD- and T2-weighted images also show the cartilage internal pathology due to the more intermediate signal of the knee joint in these sequences. Suppression of fat extends the dynamic range of tissue contrast, removes chemical shift artifacts, and decreases motion-related ghost artifacts. Like fat saturation, phase sensitive methods are also based on the difference in precession frequencies of water and fat. In this study, phase sensitive methods look at the phase difference that is accumulated in time as a result of Larmor frequency differences rather than using this difference directly. Although how MT work was given with clinical evidence that leads to quantitative model for MT in tissues, the mathematical formalism used to describe the MT effect applies to explaining to evaluate knee disorder, such as anterior cruciate ligament (ACL) tear and meniscal tear. Calculation of the effect of the effect of the MT saturation is given in the magnetization transfer ratio (MTR) which is a quantitative measure of the relative decrease in signal intensity due to the MT pulse.

  • PDF

Analysis of Stromal Cells Developed from Cord Blood CD34+ Cells (제대혈 CD34+ 세포에서 유래된 지지세포의 분석)

  • Ryu, Kyung-Ha;Park, Se-Jin;Kim, Kyung Hyo;Seoh, Ju-Young;Khan, Mohammad;Shin, Hee-Young;Ahn, Hyo-Seop
    • IMMUNE NETWORK
    • /
    • v.1 no.1
    • /
    • pp.87-94
    • /
    • 2001
  • Background: Cytokine-mediated ex vivo expansion has been proposed as a means of increasing the number of cord blood (CB) hematopoietic stem cells for transplantation. As well as stem cell number, stromal cells are necessary for functional maturation of hematopoiesis. The purpose of this study was to analyze the development of stromal cells during ex vivo expansion of CB $CD34^+$ cells. Methods : $CD34^+$ cells were purified from CB by magnetic bead selection. The levels of of interleukin-3, interleukin-$1{\beta}$, interleukin-6, granulocyte macrophagecolony stimulating factor and tumor necrosis factor-${\alpha}$ were measured in culture supernatants on 0, 1, 2, and 3 weeks, using ELISA techniques. CB $CD34^+$ cells were expanded in Iscoves modified Dulbeccos medium in the presence of several cytokines. The expression of E-selectin, vascular cell adhesion molecule-1, intercellular adhesion molecule-1, platelet/endothelial cell adhesion molecule-1, von Willebrand factor, vimentin, and CD14 in newly developed stromal cells was examined by immunocytochemical method. Relevant extracellular matrix (ECM) proteins and proper cytokines were also assayed for the most suitable condition for expansion of stromal cells. Results: Several cytokines were found to have been produced by CB $CD34^+$ cells as well as bone marrow-derived $CD34^+$ cells. During ex vivo expansion of CB $CD34^+$ cells, stromal cells appeared in the culture by day 4 and expanded over the following 7-10 days before being confluent by day 2 1. These cells expressed surface markers characteristic of cells of endothelial lineage. Furthermore, these stroaml cells also expanded effectively when treated with thrombopoietin+flt-3 ligand+stem cell factor+leukemia inhibitory factor or 0.1% poly-L-lysine-coated wells. Conclusion: Stromal cells were developed during ex vivo expansion of CB $CD34^+$ cells and that this development could be enhanced further by treating the stromal cells with cytokines or ECM.

  • PDF

Analysis of utilization and profit for CT and MRI after implementation of insurance coverage for CT (CT 보험급여 전후의 CT 및 MRI검사의 이용량과 수익성 변화)

  • Suh, Chong-Rock;Yu, Seung-Hum;Chun, Ki-Hong;Nam, Chung-Mo
    • Korea Journal of Hospital Management
    • /
    • v.2 no.1
    • /
    • pp.1-21
    • /
    • 1997
  • In order to analyze the shifts in the volume and profits of Computed Tomography(CT) and Magnetic Resonance Imaging(MRI) utilization for a year before and after the implementation of insurance coverage for CT, this study has been undertaken examining CT and MRI cost data from 'Y' University Hospital situated in Seoul, Korea. Following are the results of this study: 1. The medical insurance payment for CT, implemented on January 1, 1996, increased CT utilization from January 1996 to April 1996 due to low insurance premiums: however, from May 1996 the number of CT cases significantly decreased as a result of strengthened medical cost reviews and the new 'Detailed standards for approval of CT' announced near the end of April 1996 by the insurer. 2. Since the implementation of insurance coverage for CT, CT fee reduction rates for reimbursements by the insurer to the hospital were 50% and 40% for January and February, respectively, and 31% and 15% for March and April. A significant point in the lowering of the reduction rate was reached in May at 11%; furthermore, since June the reduction rate fell below the average reduction rate for reimbursements for all procedures. If the 'Detailed standards for approval of CT' had been announced before the implementation of insurance coverage for CT, CT utilization would not have been so high due to the need to meet those 'standards'. In addition, loss of hospital profits resulting from the reduction for reimbursements would not have occurred. 3. The shifts in MRI utilization showed that there was no particular change with the beginning of insurance coverage for CT, and the introduction of the 'Detailed standards for approval of CT' made MRI utilization increase because MRI is free of restrictions imposed by the insurer. 4. The relationship between CT utilization and MRI utilization showed that they were supplementary to each other before insurance coverage for CT, but that CT was substituted for MRI because of strengthened medical cost reviews after t~e beginning of insurance coverage for CT. 5. The shifts in volume by patient characteristics showed that the number of inappropriate case patients, according to the insurer's "Standards for approval", decreased more than the number of appropriate case patients after the introduction of insurance coverage for CT. Therefore, the health insurance fee schemes for CT have influenced patient care. 6. The shifts in profits from CT utilization showed a net profit decrease of 31.6%. In order to match the pre-coverage profit level, 5,471 more cases would need to be seen and productivity would need to be increased by 32.7%. This profit decrease resulted from a decrease of CT utilization and low reimbursements. With insurance coverage, net profits from CT were 24.4%, and a margin of safety ratio was 39.6%. Because of the net profits and margin of safety ratio, CT utilization fees for insured appropriate cases could not be considered inappropriate. 7. The shifts in profits from MRI utilization before and after the introduction of CT coverage showed that in order to match pre-CT coverage profit levels, 2,011 more cases would need to be seen and productivity would need to be increased by 9.2%. The reasons for needing to increase the number of cases and productivity result from cost burdens created by adding new MRI units. But with CT coverage already begun, MRI utilization increased. Combined with a minor increase in the MRI fee schedule, MRI utilization showed a net profit increase of 18.5%. Net profits of 62.8% and a 'margin of safety ratio' of 43.1% for MRI utilization showed that the hospital relied on this non-covered procedure for profits. 8. The shifts in profits from CT and MRI utilization showed the net profits from CT decreased by 2.33billion Won while the net profits from MRI increased by 815.7million Won. Overall, these two together showed a net profit decrease of 1.51billion Won. The shifts in utilization showed a functional substitutionary relationship, but the shifts in profits did not show a substitutionary relationship. From these results, We can conclude that if insurance is to be expanded to include previously uncovered procedures using expensive medical equipment, detailed standards should be prepared in advance. The decrease in profits from the shifts in coverage and changes in fees is a difficult burden that should be shared, not carried by the hospital alone. Also, a new or improved fee schedule system should include revised standards between items listed and the appropriateness of the fee schedule should constantly be ensured. This study focused on one university hospital in Seoul and is therefore limited in general applicability. But it is valuable for considering current issues and problems, such as the influence of CT coverage on hospital management. Future studies will hopefully expand the scope of the issues considered here.

  • PDF

Detection of Campylobacter jejuni in food and poultry visors using immunomagnetic separation and microtitre hybridization

  • Simard, Ronald-E.
    • Proceedings of the Korean Society of Fisheries Technology Conference
    • /
    • 2000.05a
    • /
    • pp.71-73
    • /
    • 2000
  • Campylobacter jejuni is most frequently identified cause of cause of acute diarrhoeal infections in developeed countries, exceeding rates of illness caused by both salmonella and shigilla(Skirrow, 1990 ; Lior 1994). Previous studies on campylobacter jejuni contamination of commercial broiler carcasses in u.s.(Stern, 1992). Most cases of the disease result from indirect transmission of Campylobactor from animals via milk, water and meat. In addition to Campylobactor jejuni. the closely relates species Campylobactor coli and Campylobactor lari have also been implicated as agents of gastroenteritis in humans. Campylobactor coli represented only approximately 3% of the Campylobactor isolates from patients with Campylobactor enteritis(Griffiths and Park, 1990) whereas Campylobactor coli is mainly isolated from pork(Lmmerding et al., 1988). Campylobactor jejuni has also been isolated from cases of bacteremia, appendicitis and, recently, has been associated with Guillai-Barre syndrome(Allos and Blaser, 1994; von Wulffen et al., 1994; Phillips, 1995). Studies in volunteers indicated that the infectious dose for Campylobactor jejuni is low(about 500 organisms)(Robinson, 1981). The methods traditionally used to detect Campylobactor ssp. in food require at least two days of incubation in an enrichment broth followed by plating and two days of incubation on complex culture media containing many antibiotics(Goossens and Butzler, 1992). Finnaly, several biochemical tests must be done to confirm the indentification at the species level. Therfore, sensitive and specific methods for the detection of small numbers of Campylobactor cells in food are needed. Polymerase chain reaction(PCR) assays targeting specific DNA sequences have been developed for the detection of Campylobactor(Giesendorf and Quint, 1995; Hemandex et al., 1995; Winter and Slavidk, 1995). In most cases, a short enrichment step is needed to enhance the sensitivity of the assay prior to detection by PCR as the number of bacteria in the food products is low in comparison with those found in dinical samples, and because the complex composition of food matrices can hinder the PCR and lower its sensitivity. However, these PCR systems are technically demanding to carry out and cumbersome when processing a large number of samples simutaneously. In this paper, an immunomagnetic method to concentrate Campylobactor cells present in food or clinical samples after an enrichment step is described. To detect specifically the thermophilic Campylobactor. a monoclonal antibody was adsorbed on the surface of the magnetic beads which react against a major porin of 45kDa present on the surface of the cells(Huyer et al., 1986). After this partial purification and concentration step, detection of bound cells was achieved using a simple, inexpensive microtitre plate-based hybridization system. We examined two alternative detection systems, one specific for thermophilic Campylobactor based on the detection of 23S rRNA using an immobilized DNA probe. The second system is less specific but more sensitive because of the high copy number of the rRNA present in bacterial cell($10^3-10^4$). By using specific immunomagnetic beads against thermophilic Campylobactor, it was possible to concentrate these cells from a heterogeneous media and obtain highly specific hybridization reactions with good sensitivity. There are several advantages in using microtitre plates instead of filter membranes or other matrices for hybridization techniques. Microtitre plates are much easier to handle than filter membranes during the adsorption, washing, hybridization and detection steps, and their use faciilitates the simultanuous analysis of multiple sample. Here we report on the use of a very simple detection procedure based on a monoclonal anti-RNA-DNA hybrid antibody(Fliss et al., 1999) for detection of the RNA-DNA hybrids formed in the wells.

  • PDF