• Title/Summary/Keyword: Dynamic ultrasonography

Search Result 58, Processing Time 0.025 seconds

Usefulness of USG in Rotator Cuff Disease (회전근 개 질환에 대한 초음파의 유용성)

  • Choi, Chang-Hyuk;Chang, Il-Woong
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.107-112
    • /
    • 2009
  • Ultrasonographic examination for the rotator cuff disease is dynamic noninvasive study and the results is comparable to MRI on the behalf of recent development. It also can be used as a tool for guided injection and follow up study after rotator cuff repair. The development of equipment, learning curve and knowledge for the disease are the three most important factors for the critical role of the ultrasonography in the diagnosis and treatment of the rotator cuff disease.

  • PDF

Ultrasonographic Guidance in Acute Achilles Tendon Rupture (급성 아킬레스 건 파열에서의 초음파 이용)

  • Lee, Tae-Hoon;Lee, Hee-Dong;Kim, Hak-Jun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.8 no.1
    • /
    • pp.26-30
    • /
    • 2015
  • There are many traumatic foot and ankle problems in orthopaedic fields. Though it is not life-threatening problems, a delay in accurate diagnosis and treatments can danger limb function and therefore correct diagnosis can prevent long-term complications. Achilles tendon rupture is relatively common injury for active sports people. Ultrasonography is cost-effective, irradiation -free, effective for evaluation of soft tissues and dynamic analysis. It has been growing importance in Achilles tendon rupture. Ultrasonography is a diagnostic tool in Achilles tendon rupture. Physical examination and patient history is needed to diagnose Achilles tendon without image, but it is missed up by 20% in private clinic. Discontinuity of normal fibrillar architecture seen on an ultrasonographic image is diagnostic for Achilles tendon rupture, and can be accentuated by the performance of dorsi-flexion and plantar flexion, while observing in real time. And ultrasonography is a reliable method for serial observation after surgical treatment or conservative treatment.

  • PDF

Ultrasonographic Findings of Normal Hip Joint and Painful Hip due to Soft Tissue Problem (고관절 초음파의 정상 소견 및 고관절 주위 질환의 초음파 소견)

  • Nam, Woo-Dong;Nam, Shin Woo;Han, Kye Young
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.1
    • /
    • pp.38-46
    • /
    • 2010
  • The lesions around hip joint including bone, joint and soft tissue can cause the pain. For diagnosis of these lesions, physical examination and simple X-ray were accomplished primarily. Some special cases, CT or MRI was a useful tool. However ultrasonography could provide non-invasive and dynamic images for the lesions of tendon and bursa, and it could be a useful tool for follow up after hip surgery. Due to the deep location of hip joint, ultrasonography is not easy for physician to examine and its application was impossible in some obese patients. This article deals with the normal and pathologic ultrasonographic findings of the hip joint and various applications using ultrasonography.

  • PDF

Parametric Image Generation and Enhancement in Contrast-Enhanced Ultrasonography (조영증강 초음파 진단에서 파라미터 영상 생성 및 개선 기법)

  • Kim, Shin-Hae;Lee, Eun-Lim;Jo, Eun-Bee;Kim, Ho-Joon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.4
    • /
    • pp.211-216
    • /
    • 2017
  • This paper proposes image processing techniques that improve usability and performance in a diagnostic system of the contrast-enhanced ultrasonography. For a methodology for visualizing diagnostic parameter data in an ultrasonic medical image, an expression of transition time data with successive pixel values and a method of generating a lesion diagnostic parameter image with four categorized values are presented. We also introduce a MRF-based image enhancement technique to eliminate noises from generated parametric images. Such parametric image generation technique can overcome the difficulty of discriminating dynamic change in patterns in the ultrasonography. The technique clarifies the contour of the region in the original image and facilitates visual determination of the characteristics of the lesion through four colors. With regard to this MRF-based image enhancement, we define the energy function of consecutive pixel values and develop a technique to optimize it, and the usability of the proposed theory is examined through experiments with medical images.

Snapping Triceps Syndrome associated with Ulnar Nerve Dislocation (척골 신경 탈구와 동반된 삼두근 탄발 증후군)

  • An, Ki Chan;Kim, Joo Yong;Gwak, Heui Chul;Kwon, Yong Wook
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.4 no.1
    • /
    • pp.28-32
    • /
    • 2011
  • Snapping triceps syndrome is a rare disease in which medial head of triceps dislocates over the medial epicondyle during elbow flexion. It is difficult to diagnose the snapping triceps syndrome, because that this syndrome is frequently misdiagnosed as other elbow disease such as ulnarnerve dislocation. The dynamic ultrasonographic imaging allows continual visualization of the ulnar nerve and triceps muscle throughout active elbow flexion and extension. We report two patients of snapping triceps syndrome who were diagnosed with the use of dynamic ultrasonography and treated with ulnar nerve anterior transposition and repositioning or resectioning of medial head of triceps.

  • PDF

Operative Treatement of Snapping Triceps Syndrome and Ulnar Nerve Dislocation (수술적으로 치료한 주관절 삼두근 탄발 증후군과 척골 신경 탈구 - 2예 보고 -)

  • Kang, Ho-Jung;Lee, Hee-Young;Lee, Jeong-Gil;Kim, Sung-Jae;Hahn, Soo-Bong
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.250-254
    • /
    • 2009
  • Purpose: Snapping triceps syndrome is dynamic condition in which medial head of triceps snaps (dislocates) over the medial epicondyle as the elbow is flexed. Materials and Methods: The symptoms are pain or snapping at the medial aspect of the elbow and/or symptoms from coexisting ulnar nerve irritation. The diagnosis can be made by dynamic ultrasonography. Results and Conclusion: And successful outcome can be archived by operative treatment, which are ulnar nerve anterior transposition and tenotomy of medial head of triceps.

Oribicularis Oris Muscle Defects in Philtral Deformities in the Repaired Cleft Lip (구순열 수술 후 인중의 변형과 구륜근 결손)

  • Kim, Suk-Wha;Jeong, Yeon-Woo;Cheon, Jung-Eun;Park, Chan-Young;Oh, Myung-June;Kim, Jung-Hong;Choi, Tae-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.427-432
    • /
    • 2010
  • Purpose: The purpose of this study is to estimate muscle defect by ultrasonography in the patients with secondary deformities of the lip. We investigated the association between the muscle defect in the repaired cleft lip and the philtral appearance not only at resting state but also maximal puckering. Methods: From December 2006 to November 2007, 52 children were evaluated after primary or secondary cheiloplasty. Digital photographs were taken both from the front and both three quarter views in repose and at maximal pucker. Video clips were also taken in repose and at maximal pucker. A panel of four, scored the philtral ridge and dimple seen on these photographs and videos by using two visual analog scales. Eminence of the philtral ridge was scored by a 5 point grading scale, from "conspicuous groove" to "normal philtral ridge" and the philtral dimple was scored by 3 point grading scale, from "no dimple" to "prominent dimple". Ultrasound images of the upper lip were made using a linear array transducer at the resting position of the lip and evaluated by a single radiologist. Results: The philtral ridge eminence scored $2.79{\pm}0.54$ and $1.40{\pm}0.53$ at resting and maximal pucker, correlating with "flat" and "conspicous groove". The philtral dimpling scored $1.44{\pm}0.53$ and $2.27{\pm}0.66$ at resting and maximal pucker, correlating with "no dimple" and "slight dimple". Ultrasound imaging showed the average muscle dehiscence to be $3.78{\pm}2.14$ mm at resting position. Correlation between the muscle defect in ultrasound imaging and philtral ridge eminence at rest was statistically significant (p<0.050), but was not significant (p=0.756) at maximal pucker using Spearman's rank correlation. Correlation between the muscle defect in ultrasound imaging and philtral dimpling was not statistically significant both at rest (p=0.920) and at maximal pucker (p=0.815) using Spearman's rank correlation. Conclusion: Quantitative assessment of the muscle defect using ultrasonography correlates with the static philtral appearance, but does not correlate with the dynamic appearance. Also, the size of the muscle defect does not show any correlation with the philtral dimpling. Our findings reveal that ultrasound imaging partially reflect static appearance of philtrum but cannot reflect dynamic appearance and suggest the need for further research to evaluate dynamic appearance.

A Parametric Image Enhancement Technique for Contrast-Enhanced Ultrasonography (조영증강 의료 초음파 진단에서 파라미터 영상의 개선 기법)

  • Kim, Ho Joon;Gwak, Seong Hoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.6
    • /
    • pp.231-236
    • /
    • 2014
  • The transit time of contrast agents and the parameters of time-intensity curves in ultrasonography are important factors to diagnose various diseases of a digestive organ. We have implemented an automatic parametric imaging method to overcome the difficulty of the diagnosis by naked eyes. However, the micro-bubble noise and the respiratory motions may degrade the reliability of the parameter images. In this paper, we introduce an optimization technique based on MRF(Markov Random Field) model to enhance the quality of the parameter images, and present an image tracking algorithm to compensate the image distortion by respiratory motions. A method to extract the respiration periods from the ultrasound image sequence has been developed. We have implemented the ROI(Region of Interest) tracking algorithm using the dynamic weights and a momentum factor based on these periods. An energy function is defined for the Gibbs sampler of the image enhancement method. Through the experiments using the data to diagnose liver lesions, we have shown that the proposed method improves the quality of the parametric images.

Comparison of ultrasonography guided serratus anterior plane block and thoracic paravertebral block in video-assisted thoracoscopic surgery: a prospective randomized double-blind study

  • Baytar, Merve Sena;Yilmaz, Canan;Karasu, Derya;Baytar, Cagdas
    • The Korean Journal of Pain
    • /
    • v.34 no.2
    • /
    • pp.234-240
    • /
    • 2021
  • Background: Various truncal block techniques with ultrasonography (USG) are becoming widespread to reduce postoperative pain and opioid requirements in video-assisted thoracoscopic surgery (VATS). The primary aim of our study was to determine whether the USG-guided serratus anterior plane block (SAPB) is as effective as the thoracic paravertebral block (TPVB) in VATS. Our secondary aim was to evaluate patient and surgeon satisfaction, block application time, first analgesic time, and length of hospital stay. Methods: Patients in Group SAPB received 0.4 mL/kg bupivacaine with a USG-guided SAPB, and patients in Group TPVB received 0.4 mL/kg bupivacaine with a USG-guided TPVB. We recorded the pain scores, the timing of the first analgesic requirement, the amount of tramadol consumption, and postoperative complications for 24 hours. We also recorded the block application time and length of hospital stay. Results: A total of 62 patients, with 31 in each group (Group SAPB and Group TPVB) completed the study. Between the two groups, there were no significant differences in rest and dynamic pain visual analog scale scores at 0, 1, 6, 12, and 24 hours after surgery. The total consumption of tramadol was significantly lower in the TPVB group (P = 0.026). The block application time was significantly shorter in Group SAPB (P < 0.001). Conclusions: An SAPB that is applied safely and rapidly as a part of multimodal analgesia in patients who undergo VATS is not inferior to the TPVB and can be an alternative to it.

Comparison of Tibialis Anterior Muscle Thickness with 4 Different Toe and Ankle Postures: Ultrasonographic Study

  • Jang, Tae-Jin;Hwang, Byeong-Hun;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.1
    • /
    • pp.12-17
    • /
    • 2022
  • Purpose: Ankle dorsiflexion is an essential element of normal functions, including walking, activities of daily living and sport activities. The tibialis anterior (TA) muscle functioned as a dorsiflexor and as a dynamic stabilizer of the ankle joint during walking and jumping. This study aimed to compare TA muscle thickness using ultrasonography according to the four different toe and ankle postures for the selective TA strengthening exercise. Methods: This study were recruited 26 (males: 15, females: 11) aged 20-30 years, with no injury ankle and calf in the medical history, had normal dorsiflexion and inversion range of motion (ROM). The thickness of the TA muscle was measured by ultrasonography in the four different toe and ankle postures: 1. Ankle dorsiflexion with all toe extension and ankle inversion (ITEDF); 2. Ankle dorsiflexion with all toe flexion and ankle inversion (ITFDF); 3. Ankle dorsiflexion with all toe extension and neutral position (NTEDF); 4. Ankle dorsiflexion with all toe flexion and neutral position (NTFDF). One-way repeated analysis of variance (ANOVA) and Bonferroni correction were used to confirm the significant difference among conditions. The level of statistical significance was set at α=0.01. Results: TA muscle thickness with ITFDF was significantly greater than in any other ankle positions, including ITEDF, NTFDF, and NTEDF (p<0.01). Conclusion: Among the four toe and ankle postures, isometric contraction in ITFDF postures showed the greatest increase in thickness of TA rather than ITEDF, NTEDF, and NTFDF postures. Based on these results, ITFDF can be recommended in an efficient way to selectively strengthen TA muscle.