• 제목/요약/키워드: Dynamic load test

검색결과 895건 처리시간 0.03초

유니버설조인트 시험방식을 이용한 치과용 임플란트의 피로시험 및 가속수명시험에 관한 연구 (Study on the Fatigue Test and the Accelerated Life Test for Dental Implant using Universal-Joint Test Type)

  • 도경훈;이석진;김종미;김성민
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제17권1호
    • /
    • pp.50-57
    • /
    • 2017
  • Purpose : This paper is a comparative analysis results of the fatigue test for dental implants and accelerated life test by using a static type loading device commonly used in Korea and a dynamic type loading device (universal-joint) recommended by FDA. Methods : Fatigue tests of dental implant is based on ISO 14801 and classified into static load test and dynamic load test. The tests were carried out on three test specimens by four load stress steps under each loading device. For analysis on failure mode such as crack, fracture and permanent deformation of test specimens, we used X-ray three-dimensional computed tomography on test specimens before and after the fatigue tests. The design of the accelerated life test was based on the analysis results of the fatigue life data obtained from the dynamic load test and the statistical analysis software (Minitab ver.15) was used to analyze the appropriate life distribution. Results : As a result of the fatigue tests and the accelerated life tests at same acceleration condition under each test method, the fatigue life under the dynamic type loading device (universal-joint) was shorter than when static type loading device was applied. Conclusion : This paper can be used as a reference when the universal-joint type loading device for implants fatigue test is applied as ISO 14801.

건물의 외주부 존에 대한 동적 부하모델 이용 피크냉방부하 저감효과 분석 (Evaluation on Reducing Peak Cooling Load Based on Dynamic Load Model of Building Perimeter Zones)

  • 이경호
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.1-8
    • /
    • 2011
  • In this paper, inverse building modeling was applied to building perimeter zones which have different window orientation. Two test zones of east-facing and west-facing zones in ERS(Energy Resource Station) building, which is representative of small commercial building, was used to test performance of cooling load calculation and peak cooling load reduction. The dynamic thermal load model for the east and west zone was validated using measured data for the zones and then it was used to investigate the effect of peak cooling load reduction by adjustment of indoor cooling temperature set points during on-peak time period. For the east zone, the peak load can be reduced to about 60% of the peak load for conventional control even without any precooling. For the west zone, PLR is nearly independent of the start of the on-peak period until a start time of 1pm. Furthermore, PLR has a small dependence on the precooling duration. Without any precooling, the peak cooling load can be reduced to about 35% of the peak load associated with conventional control.

주행시험기를 이용한 차륜의 안전성 평가에 관한 연구 (A Study on Safety Evaluation of Wheel Using Roller Rig Tester)

  • 함영삼
    • 한국정밀공학회지
    • /
    • 제32권7호
    • /
    • pp.591-595
    • /
    • 2015
  • The roller rig tester for safety performance evaluation of wheel derailment is a test facility which can give the test load condition to the test wheel, similar to the actual dynamic condition in actual running condition. This study describes the evaluation result on the durability of the resilient wheel equipped with the ring damper and the damping material, and installed in the half part of a full scaled bogie in combination with the primary spring when it rotates under the dynamic condition. The evaluation result on durability of resilient wheel after load test of 2 million cycles shows that the safety of wheel is not affected by the applied load in visual inspection and nondestructive test, however, in the bolt used for fastening the ring damper to the wheel the loosening was found. Accordingly the use of self-locking nut and washer is recommended.

Field distribution factors and dynamic load allowance for simply supported double-tee girder bridges

  • Kidd, Brian;Rimal, Sandip;Seo, Junwon;Tazarv, Mostafa;Wehbe, Nadim
    • Structural Engineering and Mechanics
    • /
    • 제82권1호
    • /
    • pp.69-79
    • /
    • 2022
  • This paper discusses the field testing of two single-span double-tee girder (DTG) bridges in South Dakota to determine live load distribution factors (LLDFs) and the dynamic load allowance (IM). One bridge had seven girders and another had eight girders. The longitudinal girder-to-girder joints of both bridges were deteriorated in a way that water could penetrate and the joint steel members were corroded. A truck traveled across each of the two bridges at five transverse paths. The paths were tested twice with a crawl speed load test and twice with a dynamic load. The LLDFs and IM were determined using strain data measured during the field tests. These results were compared with those determined according to the AASHTO Standard and the AASHTO LRFD specifications. Nearly all the measured LLDFs were below the AASHTO LRFD design LLDFs, with the exception of two instances: 1) An exterior DTG on the seven-girder bridge and 2) An interior DTG on the eight-girder bridge. The LLDFs specified in the AASHTO Standard were conservative compared with the measured LLDFs. It was also found that both AASHTO LRFD and AASHTO Standard specifications were conservative when estimating IM, compared to the field test results for both bridges.

판토그라프 접촉력 측정을 위한 스트레인 게이지 내장형 센서 개발 (Development of Load Cell to Measure Contact Force of Pantograph)

  • 박찬경;백진성;김영국;김기환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.947-953
    • /
    • 2010
  • The KTX-Sancheon has been commercially operating on the high-speed line since March. 2. In order to verify the performance of high-speed train and core equipments such as current collection system, sophisticated tests and evaluating procedures should have been considering. In this paper, the load cell with a built-in strain-gauge which developed to improve measuring method of contact force between the pantograph and catenary system is introduced. The static test results of the load cell shows that its design is very suitable and applicable for the dynamic test and on-line test. After the test and evaluation of load cell's dynamic calibration with pantograph, we will be applied to test interaction characteristics between the pantograph and catenary system on the high-speed line.

  • PDF

부하차단시험에 의한 서인천복합화력 발전기.제어계의 모델링 및 검증 (Modeling and verification of generator/control system of Seo-Inchon combined-cycle plant by load rejection test)

  • 최경선;문영환;김동준;추진부;류승헌;권태원
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.501-510
    • /
    • 1996
  • The gas-turbine generator of Seo-Incheon combined-cycle plant was tested for derivation of a model for dynamic analysis. Load rejection and AVR step test was performed to get the dynamic response of generator. The parameters of generator/control system model were determined by these measured data. No-load saturation test was performed for the saturation characteristics of the generator under steady state. V-curve test was also performed so as to find exact generator parameters. Q-axis parameters of generator was derived by measuring power angle. AVR and governor constants have been tuned by their oscillatory period and setting time characteristics. The derived parameters of generator control system is verified by one-machine infinite bus system simulation. (author). 7 refs., 20 figs., 5 tabs.

  • PDF

차량의 동적 상호작용에 관한 이론연구 및 윤하중 실험 (An Analytical and Experimental Wheel Tracking Study on Dynamic Interaction of Vehicle)

  • 김낙석;박석순
    • 한국재난정보학회 논문집
    • /
    • 제2권1호
    • /
    • pp.39-52
    • /
    • 2006
  • In this paper, an analytical and experimental study was performed in order to determine the effects of interaction between vehicle and structure. Results presented in the paper show that analytical method including moving load effect can investigate the trend of structural response due to dynamic interaction between vehicle and structure. The wheel tracking machine fitted with 2-axle test vehicle can demonstrate more accurate dynamic interaction between vehicle and structure than the wheel tracking machine fitted without 2-axle test vehicle.

  • PDF

동적 초미소 경도법에 의한 심도별 대전화강암 내 광물들의 역학적 특성 (Mechanical Properties of Minerals in Daejeon Granite According to Depths by Dynamic Ultra-micro Hardness)

  • 최정해;신주호;장형두;강성승
    • 터널과지하공간
    • /
    • 제27권3호
    • /
    • pp.172-184
    • /
    • 2017
  • 동적 초미소 경도법의 압입시험, 하중-비하중 시험, 그리고 반복시험을 이용하여 심도별 대전화강암 내 광물들의 경도와 역학적 특성을 살펴보았다. 시험 결과 세 개 구간(Group-1, -2, -3)으로 광물 집단의 분류가 가능하였다. Martens 경도값은 세 가지 시험법 모두에서 41 m와 223 m 심도에 따른 차이가 크지 않았다. 그럼에도 불구하고, 그 크기는 반복시험<하중-비하중 시험<압입시험 순으로 나타났다. 광물 집단별 평균 Martens 경도, 탄성계수, indentation work 등을 고려해 볼때, 그들의 경계는 비교적 뚜렷하게 나타났다. 결론적으로 동적 초미소 경도법의 세 가지 형태 시험법을 이용함으로써 광물들에 대한 비교적 정확한 경도값을 얻을 수 있었다. 또한 하중-비하중 시험과 반복시험으로부터는 광물들의 탄성계수와 광물들의 탄성적-소성적 성질 특성 파악도 가능하였다.

실하중 이력에 의한 조인트의 동적강도해석 (Dynamic Stress Analysis of joint by Practical Dynamic Load History)

  • 송준혁;강희용;양성모
    • 한국공작기계학회논문집
    • /
    • 제10권5호
    • /
    • pp.118-123
    • /
    • 2001
  • Most structures of automobile are composed of many substructures connected to one another by various types of mechanical joints. In automotive engineering, it is important to study these connected structures under various dynamic farces for the evaluations of fatigue life and stress concentration exactly. It is rarely obtained the accurate load history of specified positions because of the errors such as modeling, measurement, and etc. In the beginning of design, exact load data are actually necessary for the fatigue strength and life analysis to minimize the cost and time of designing. In this paper, the procedure of practical dynamic load determination is developed by the combination of the principal stresses of F.E. analysis and experiment. Inverse problem and least square pseudo inverse matrix are adopted to obtain an inverse matrix of analyzed stresses matrix. Pseudo-Practical dynamic load was calculated for Lab. Test of sub-structure. GUI program(PLODAS) was developed for whole of above procedure. This proposed method could be extended to any geometric shape of structure.

  • PDF

동적재하시험을 통한 PSC 거더교의 횡분배 측정 (Lateral Load Distribution Estimation of a PSC Girder Bridge from Dynamic Loading Test)

  • 김성완;정진환;김성도;박재봉;이명진
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권3호
    • /
    • pp.60-68
    • /
    • 2017
  • 교량은 사회간접시설물의 핵심이 되는 도로의 주요 시설물이므로 공용기간 동안 안정성과 사용성이 확보될 수 있도록 건설되며, 교량의 안전성 확보를 위하여 현재 상태에서 건전성을 평가하는 것은 유지관리 업무에서 중요한 과제이다. 일반적으로 교량의 내하력 평가를 위해 차량재하시험을 통하여 횡분배율을 측정함으로써 교량의 중첩거동 및 대칭거동을 확인할 수 있다. 그러나 공용중인 교량의 횡분배율을 측정하기 위하여 정적재하시험을 수행하고 있으며 교통통제의 어려움이 있다. 따라서 본 연구에서는 동적재하시험 및 상시진동시험에서 측정된 교량의 변위응답 데이터를 경험적 모드분해기법을 이용하여 정적 성분의 변위를 추출하였다. 추출된 정적 성분의 변위를 이용하여 횡분배율을 추정하였으며, 정적재하시험에서 측정된 횡분배율과 비교하였다.