• Title/Summary/Keyword: Dynamic grid

Search Result 579, Processing Time 0.021 seconds

Thermo-fluid Dynamic and Missile-motion Performance Analysis of Gas-Steam Launch System Utilizing Multiphase Flow Model and Dynamic Grid System (다상 유동모델과 동적 격자계를 활용한 가스-스팀 발사체계의 열유동과 탄의 운동성능 해석)

  • Kim, Hyun Muk;Bae, Seong Hun;Park, Cheol Hyeon;Jeon, Hyeok Soo;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.2
    • /
    • pp.48-59
    • /
    • 2017
  • In this study, an analysis of the thermo-fluid dynamic and missile-motion performance was carried out through a numerical simulation inside the missile canister. Calculation was made in an analytical volume using dynamic grid and evaporated water was used as a coolant. To analyze the interaction among the hot gas, coolant, and mixture flow, Realizable $k-{\varepsilon}$ turbulence and VOF (Volume Of Fluid) model were chosen and a parametric study was performed with the change of coolant flow rate. As a result of the analysis, pressure of the canister showed a large difference depending on the presence or absence of the coolant, and also showed a dependancy on the amount of coolant. Velocity and acceleration were dependent on the canister pressure.

Design and Evaluation of a Dynamic Continuous Media Streaming Supporting Method on the basis of Logical Grid Hierarchy for MANETs

  • Bae, Ihn-Han
    • Journal of the Korean Data and Information Science Society
    • /
    • v.19 no.2
    • /
    • pp.645-655
    • /
    • 2008
  • As wireless connectivity is integrated into many handheld devices, streaming multimedia content among mobile ad-hoc peers is becoming a popular application. In this paper, we propose a dynamic service replication algorithm for providing guaranteed continuous streaming services to all nodes in mobile ad-hoc networks (MANETs). First, a MANET is comprised of logical grid hierarchy, and a streaming service is replicated to a lower server region of the logical grid hierarchy by considering the link availability between a mobile node and the streaming server within a server region or the popularity of the streaming service. We evaluate analytically the performance of the proposed algorithm, and compared with that of existing Qin's algorithm. Evaluation results show that our algorithm can achieve better streaming performance than Qin's algorithm. Therefore, the proposed algorithm not only improves the sharing availability of replicated streaming services but also controls efficiently the number of streaming service replications.

  • PDF

Path Finding with Minimum Speed Dynamic Heuristic (최저 속력 동적 휴리스틱을 이용한 경로탐색)

  • Moon, Dae-Jin;Cho, Dae-Soo
    • Journal of Korea Spatial Information System Society
    • /
    • v.10 no.2
    • /
    • pp.35-48
    • /
    • 2008
  • In this paper, we propose a Dynamic Heuristic to reduce the number of node accesses and improve quality of path in the client-based navigation service. The Dynamic Heuristic is to use heuristic data from server that is calculated with traffic data. The server-based navigation service provides a path searched on server and transmits it to client, but we propose that server only provide heuristic data to client. The proposed client searches a path with heuristic transmitted data from server. We present a new algorithm for using Dynamic Heuristic in the path-finding. The algorithm bases Grid Based Path-Finding, and has minimum speed data of edges in grid. It removes several grids whose minimum speed is less than limited speed.

  • PDF

Efficient Continuous Skyline Query Processing Scheme over Large Dynamic Data Sets

  • Li, He;Yoo, Jaesoo
    • ETRI Journal
    • /
    • v.38 no.6
    • /
    • pp.1197-1206
    • /
    • 2016
  • Performing continuous skyline queries of dynamic data sets is now more challenging as the sizes of data sets increase and as they become more volatile due to the increase in dynamic updates. Although previous work proposed support for such queries, their efficiency was restricted to small data sets or uniformly distributed data sets. In a production database with many concurrent queries, the execution of continuous skyline queries impacts query performance due to update requirements to acquire exclusive locks, possibly blocking other query threads. Thus, the computational costs increase. In order to minimize computational requirements, we propose a method based on a multi-layer grid structure. First, relational data object, elements of an initial data set, are processed to obtain the corresponding multi-layer grid structure and the skyline influence regions over the data. Then, the dynamic data are processed only when they are identified within the skyline influence regions. Therefore, a large amount of computation can be pruned by adopting the proposed multi-layer grid structure. Using a variety of datasets, the performance evaluation confirms the efficiency of the proposed method.

A Second-order Harmonic Current Reduction with a Fast Dynamic Response for a Two-stage Single-phase Grid-connected Inverter

  • Jung, Hong-Ju;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1988-1994
    • /
    • 2014
  • In a single-phase grid-connected power system consisting of a DC/DC converter and a DC/AC converter, the current drawn from renewable energy sources has a tendency to be pulsated and contains second-order frequency ripple components, which results in several drawback such as a power harvesting loss and a shortening of the energy source's life. This paper presents a new second-order harmonic current reduction scheme with a fast dc-link voltage loop for two-stage dc-dc-ac grid connected systems. In the frequency domain, an adequate control design is performed based on the small signal transfer function of a two-stage dc-dc-ac converter. To verify the effectiveness of proposed control algorithm, a 1 kW hardware prototype has been built and experimental results are presented.

Nonlinear Dynamic Buckling Behavior of a Partial Spacer Grid Assembly

  • Yoon, Kyung-Ho;Kang, Heung-Seok;Kim, Hyung-Kyu;Song, Kee-Nam;Jung, Yeon-Ho
    • Nuclear Engineering and Technology
    • /
    • v.33 no.1
    • /
    • pp.93-101
    • /
    • 2001
  • The spacer grid is one of the main structural components in the fuel assembly, which supports the fuel rods, guides cooling water, and protects the system from an external impact load, such as earthquakes. Therefore, the mechanical and structural properties of the spacer grids must be extensively examined while designing them. In this paper, a numerical method for predicting the buckling strength of spacer grids is presented. Numerical analyses on the buckling behavior of the spacer grids are performed for a various array of sizes of the grids considering that the spacer grid is an assembled structure with thin-walled plates and imposing proper boundary conditions by nonlinear dynamic finite element method using ABAQUS/Explicit. Buckling tests on several numbers of specimens of the spacer grid were also carried out in order to compare the results between the test and the simulation result. The drop test is accomplished by dropping a carriage on the specimen at a pre-determined position. From this test, the specimens are buckled only at the uppermost and the lowermost layer among the multi-cells, which is similar to the local buckling at the weakest point of the grid structure. The simulated results also similarly predicted the local buckling phenomena and were found to give good correspondence with the experimental values for the thin-walled grid structures.

  • PDF

Accurate Voltage Parameter Estimation for Grid Synchronization in Single-Phase Power Systems

  • Dai, Zhiyong;Lin, Hui;Tian, Yanjun;Yao, Wenli;Yin, Hang
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.1067-1075
    • /
    • 2016
  • This paper presents an adaptive observer-based approach to estimate voltage parameters, including frequency, amplitude, and phase angle, for single-phase power systems. In contrast to most existing estimation methods of grid voltage parameters, in this study, grid voltage is treated as a dynamic system related to an unknown grid frequency. Based on adaptive observer theory, a full-order adaptive observer is proposed to estimate voltage parameters. A Lyapunov function-based argument is employed to ensure that the proposed estimation method of voltage parameters has zero steady-state error, even when frequency varies or phase angle jumps significantly. Meanwhile, a reduced-order adaptive observer is designed as the simplified version of the proposed full-order observer. Compared with the frequency-adaptive virtual flux estimation, the proposed adaptive observers exhibit better dynamic response to track the actual grid voltage frequency, amplitude, and phase angle. Simulations and experiments have been conducted to validate the effectiveness of the proposed observers.

Dynamic analysis method for the progressive collapse of long-span spatial grid structures

  • Tian, Li-min;Wei, Jian-peng;Hao, Ji-ping;Wang, Xian-tie
    • Steel and Composite Structures
    • /
    • v.23 no.4
    • /
    • pp.435-444
    • /
    • 2017
  • In the past, the progressive collapse resulting from local failures during accidents has caused many tragedies and loss of life. Although long-span spatial grid structures are characterised by a high degree of static indeterminacy, the sudden failure of key members may lead to a catastrophic progressive collapse. For this reason, it is especially necessary to research the progressive collapse resistance capacity of long-span spatial grid structures. This paper presents an evaluation method of important members and a novel dynamic analysis method for simulating the progressive collapse of long-span spatial grid structures. Engineering cases were analysed to validate these proposed method. These proposed methods were eventually implemented in the progressive collapse analysis of the main stadium for the Universiade Sports Center. The roof of the structure was concluded to have good resistance against progressive collapse. The novel methods provide results close to practice and are especially suitable for the progressive collapse analysis of long-span spatial grid structures.

Versatile UPQC Control System with a Modified Repetitive Controller under Nonlinear and Unbalanced Loads

  • Trinh, Quoc-Nam;Lee, Hong-Hee
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.1093-1104
    • /
    • 2015
  • A standard repetitive controller (RC) is theoretically able to replace a bank of resonant controllers in harmonic signals tracking applications. However, the traditional RC has some drawbacks such as a poor dynamic response and a complex structure to compensate grid frequency deviations for an effective unified power quality conditioner (UPQC) control scheme. In order to solve these problems, an improved RC with an outstanding dynamic response and a simplified grid frequency adaptive scheme is proposed for UPQC control systems in this paper. The control strategy developed for the UPQC has delay time, i.e., one-sixth of a fundamental period (Tp/6), repetitive controllers. As a result, the UPQC system can provide a fast dynamic response along with good compensation performance under both nonlinear and unbalanced loads. Furthermore, to guarantee the excellent performance of the UPQC under grid frequency deviations, a grid frequency adaptive scheme was developed for the RC using a simple first order Padé's approximation. When compared with other approaches, the proposed control method is simpler in structure and requires little computing time. Moreover, the entire control strategy can be easily implemented with a low-cost DSP. The effectiveness of the proposed control method is verified through various experimental tests.

Complex Vector Modeling and Series Decoupling Current Control Strategy of High-Power L/LCL Type Grid-Connected Converter Under Low Switching Frequency

  • Wang, Yingjie;Jiao, Lanyi;Yang, Bo;Wang, Wenchao;Liu, Haiyuan
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1879-1888
    • /
    • 2018
  • With power level of grid-connected converters rising, the switching frequency of the switching devices is commonly greatly reduced to improve its power capacity. However, this results in serious couplings of the dq current components, which leads to degradation of the static and dynamic performances of grid-connected converters and fluctuations of the reactive power in dynamic processes. In this paper, complex vector models under low switching frequency are established for an L/LCL grid-connected converter, and the relationship between the switching frequency and the coupling degree is analyzed. In addition, a series decoupling current control strategy is put forward. It is shown that the proposed control strategy can eliminate the couplings, improve the performances and have good robustness to parameter variations through static and dynamic characteristics analyses and a sensitivity analysis. Experimental and simulation results also verify the correctness of the theoretical analyses and the superiority of the proposed control strategy.