• Title/Summary/Keyword: Dynamic flow

Search Result 2,804, Processing Time 0.036 seconds

A Two Mobilized-Plane Model for Soil Liquefaction Analysis (액상화해석을 위한 두 개의 활성면을 가진 구성모델)

  • Park, Sung-Sik
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.10
    • /
    • pp.173-181
    • /
    • 2006
  • A Two Mobilized-Plane Model is proposed for monotonic and cyclic soil response including liquefaction. This model is based on two mobilized planes: a plane of maximum shear stress, which rotates, and a horizontal plane which is spatially fixed. By controlling two mobilized planes, the model can simulate the principal stress rotation effect associated with simple shear from different $K_0$ states. The proposed model gives a similar skeleton behaviour for soils having the same mean stress, regardless of $K_0$ conditions as observed in laboratory tests. The soil skeleton behaviour observed in cyclic drained simple shear tests, including compaction during unloading and dilation at large strain is captured in the model. Undrained monotonic and cyclic response is predicted by imposing the volumetric constraint of the water on the drained or skeleton behaviour. This constitutive model is incorporated into the dynamic coupled stress-flow finite difference program of FLAC (Fast Lagrangian Analysis of Continua). The model was first calibrated with drained simple shear tests on Fraser River sand, and verified by comparing predicted and measured undrained behaviour of Fraser River sand using the same input parameters.

Netflix, Amazon Prime, and YouTube: Comparative Study of Streaming Infrastructure and Strategy

  • Suman, Pandey;Yang-Sae, Moon;Mi-Jung, Choi
    • Journal of Information Processing Systems
    • /
    • v.18 no.6
    • /
    • pp.729-740
    • /
    • 2022
  • Netflix, Amazon Prime, and YouTube are the most popular and fastest-growing streaming services globally. It is a matter of great interest for the streaming service providers to preview their service infrastructure and streaming strategy in order to provide new streaming services. Hence, the first part of the paper presents a detailed survey of the Content Distribution Network (CDN) and cloud infrastructure of these service providers. To understand the streaming strategy of these service providers, the second part of the paper deduces a common quality-of-service (QoS) model based on rebuffering time, bitrate, progressive download ratio, and standard deviation of the On-Off cycle. This model is then used to analyze and compare the streaming behaviors of these services. This study concluded that the streaming behaviors of all these services are similar as they all use Dynamic Adaptive Streaming over HTTP (DASH) on top of TCP. However, the amount of data that they download in the buffering state and steady-state vary, resulting in different progressive download ratios, rebuffering levels, and bitrates. The characteristics of their On-Off cycle are also different resulting in different QoS. Hence a thorough adaptive bit rate (ABR) analysis is presented in this paper. The streaming behaviors of these services are tested on different access network bandwidths, ranging from 75 kbps to 30 Mbps. The survey results indicate that Netflix QoS and streaming behavior are significantly consistent followed by Amazon Prime and YouTube. Our approach can be used to compare and contrast the streaming services' strategies and finetune their ABR and flow control mechanisms.

Performance Evaluation of SDN Controllers: RYU and POX for WBAN-based Healthcare Applications

  • Lama Alfaify;Nujud Alnajem;Haya Alanzi;Rawan Almutiri;Areej Alotaibi;Nourah Alhazri;Awatif Alqahtani
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.7
    • /
    • pp.219-230
    • /
    • 2023
  • Wireless Body Area Networks (WBANs) have made it easier for healthcare workers and patients to monitor patients' status continuously in real time. WBANs have complex and diverse network structures; thus, management and control can be challenging. Therefore, considering emerging Software-defined networks (SDN) with WBANs is a promising technology since SDN implements a new network management and design approach. The SDN concept is used in this study to create more adaptable and dynamic network architectures for WBANs. The study focuses on comparing the performance of two SDN controllers, POX and Ryu, using Mininet, an open-source simulation tool, to construct network topologies. The performance of the controllers is evaluated based on bandwidth, throughput, and round-trip time metrics for networks using an OpenFlow switch with sixteen nodes and a controller for each topology. The study finds that the choice of network controller can significantly impact network performance and suggests that monitoring network performance indicators is crucial for optimizing network performance. The project provides valuable insights into the performance of SDN-based WBANs using POX and Ryu controllers and highlights the importance of selecting the appropriate network controller for a given network architecture.

Comparison of Resin Impregnation and Mechanical Properties of Composites Based on Fiber Plasma Treatment (섬유 플라즈마 처리에 따른 복합재료의 수지 함침성 및 기계적 특성 비교)

  • Seong Baek Yang;Donghyeon Lee;Yongseok Lee;Dong-Jun Kwon
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.388-394
    • /
    • 2023
  • In composites manufacturing, increasing resin impregnation is a key way to speed up the manufacturing process and improve product quality. While resin improvement is important, simple fiber surface treatments can also improve resin flowability. In this study, different plasma treatment times were applied to carbon fiber fabrics to improve the impregnation between resin and fiber. Electrical resistivity measurements were used to evaluate the dispersion of resin in the fibers, which changed with plasma treatment. The effect of fiber surface treatment on resin spreadability could be observed in real time. When inserting a carbon fiber tow into the resin, the amount of resin that soaked into the tow was measured to objectively compare resin impregnation. Five minutes of plasma treatment improved the tensile and compressive strength of the composite by more than 50%, while reducing the void content and increasing the fire point impregnation flow rate. Finally, a dynamic flexural fatigue test was conducted using a portion of the composite used as an architectural composite part, and the composite part did not fail after one million cycles of a 3 kN load.

Monitoring Cerebral Perfusion Changes Using Arterial Spin-Labeling Perfusion MRI after Indirect Revascularization in Children with Moyamoya Disease

  • Seul Bi Lee;Seunghyun Lee;Yeon Jin Cho;Young Hun Choi;Jung-Eun Cheon;Woo Sun Kim
    • Korean Journal of Radiology
    • /
    • v.22 no.9
    • /
    • pp.1537-1546
    • /
    • 2021
  • Objective: To assess the role of arterial spin-labeling (ASL) perfusion MRI in identifying cerebral perfusion changes after indirect revascularization in children with moyamoya disease. Materials and Methods: We included pre- and postoperative perfusion MRI data of 30 children with moyamoya disease (13 boys and 17 girls; mean age ± standard deviation, 6.3± 3.0 years) who underwent indirect revascularization between June 2016 and August 2017. Relative cerebral blood flow (rCBF) and qualitative perfusion scores for arterial transit time (ATT) effects were evaluated in the middle cerebral artery (MCA) territory on ASL perfusion MRI. The rCBF and relative time-to-peak (rTTP) values were also measured using dynamic susceptibility contrast (DSC) perfusion MRI. Each perfusion change on ASL and DSC perfusion MRI was analyzed using the paired t test. We analyzed the correlation between perfusion changes on ASL and DSC images using Spearman's correlation coefficient. Results: The ASL rCBF values improved at both the ganglionic and supraganglionic levels of the MCA territory after surgery (p = 0.040 and p = 0.003, respectively). The ATT perfusion scores also improved at both levels (p < 0.001 and p < 0.001, respectively). The rCBF and rTTP values on DSC MRI showed significant improvement at both levels of the MCA territory of the operated side (all p < 0.05). There was no significant correlation between the improvements in rCBF values on the two perfusion images (r = 0.195, p = 0.303); however, there was a correlation between the change in perfusion scores on ASL and rTTP on DSC MRI (r = 0.701, p < 0.001). Conclusion: Recognizing the effects of ATT on ASL perfusion MRI may help monitor cerebral perfusion changes and complement quantitative rCBF assessment using ASL perfusion MRI in patients with moyamoya disease after indirect revascularization.

The development of a new type of functional fresh apple juice using prebiotic fibers, ginger extract, and cardamom essential oil: Antioxidant capacity and chemical analysis

  • Hamed Hassanzadeh;Mohammadyar Hosseini;Yaseen Galali;Babak Ghanbarzadeh
    • Food Science and Preservation
    • /
    • v.30 no.5
    • /
    • pp.743-757
    • /
    • 2023
  • The formulation of a novel functional fresh apple juice enriched with dietary prebiotic fiber (inulin or polydextrose), ginger extract (GE), and cardamom essential oil (CEO) was carried out based on a combined D-optimal design. In the first stage, sensory evaluation was performed to screen and select the optimum sample for further experiments. The sensory evaluation showed that the sample containing inulin 0.25 g/100 g GE and 0.03 g/100 g CEO had the highest organoleptic score. In the second stage, various chemical experiments, including pH, acidity, formalin index, total phenol, flavonoids, antioxidant capacity, and vitamin C content, were evaluated on the selected enriched apple juices. The addition of GE and CEO caused changes in nutritional characteristics, including antioxidant capacity, total phenol, flavonoids, vitamin C, and IC50, from 35 g/100 g, 350 mg GAE/g, 17 mg/L, 370 mg/kg, and 1,800 mg/kg to 45 g/100 g, 460 mg GAE/g, 21 mg/L, 420 mg/kg, and 1,200 mg/kg respectively. The steady shear flow and dynamic oscillatory shear rheological tests were also performed on the screened samples, and results showed that the addition of dietary fiber in apple juices increased the apparent viscosity, storage modulus, loss modulus, and complex viscosity. In general, adding plant extracts and processed essential oil to apple juice increased the nutritional-nutraceutical value and sensory attributes of apple juice.

Dynamic Contrast-Enhanced Ultrasound of Gastric Cancer: Correlation with Perfusion CT and Histopathology

  • Ijin Joo;Se Hyung Kim;Dong Ho Lee;Joon Koo Han
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.781-790
    • /
    • 2019
  • Objective: To assess the relationship between contrast-enhanced ultrasound (CEUS) parameters and perfusion CT (PCT) parameters of gastric cancers and their correlation with histologic features. Materials and Methods: This prospective study was approved by our Institutional Review Board. We included 43 patients with pathologically-proven gastric cancers undergoing CEUS using SonoVue® (Bracco) and PCT on the same day. Correlation between the CEUS parameters (peak intensity [PI], area under the curve [AUC], rise time [RT] from 10% to 90% of PI, time to peak [TTPUS], and mean transit time [MTTUS]) and PCT parameters (blood flow, blood volume, TTPCT, MTTCT, and permeability surface product) of gastric cancers were analyzed using Spearman's rank correlation test. In cases of surgical resection, the CEUS and PCT parameters were compared according to histologic features using Mann-Whitney test. Results: CEUS studies were of diagnostic quality in 88.4% (38/43) of patients. Among the CEUS parameters of gastric cancers, RT and TTPUS showed significant positive correlations with TTPCT (rho = 0.327 and 0.374, p = 0.045 and 0.021, respectively); PI and AUC were significantly higher in well-differentiated or moderately-differentiated tumors (n = 4) than poorly-differentiated tumors (n = 18) (p = 0.026 and 0.033, respectively), whereas MTTCT showed significant differences according to histologic types (poorly cohesive carcinoma [PCC] vs. non-PCC), T-staging (≤ T2 vs. ≥ T3), N-staging (N0 vs. N-positive), and epidermal growth factor receptor expression (≤ faint vs. ≥ moderate staining) (p values < 0.05). Conclusion: In patients with gastric cancers, CEUS is technically feasible for the quantification of tumor perfusion and may provide correlative and complementary information to that of PCT, which may allow prediction of histologic features.

Dye-Perfused Human Placenta for Simulation in a Microsurgery Laboratory for Plastic Surgeons

  • Laura C. Zambrano-Jerez;Karen D. Diaz-Santamaria;Maria A. Rodriguez-Santos;Diego F. Alarcon-Ariza;Genny L. Melendez-Florez;Monica A. Ramirez-Blanco
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.627-634
    • /
    • 2023
  • In recent decades, a number of simulation models for microsurgical training have been published. The human placenta has received extensive validation in microneurosurgery and is a useful instrument to facilitate learning in microvascular repair techniques as an alternative to using live animals. This study uses a straightforward, step-by-step procedure for instructing the creation of simulators with dynamic flow to characterize the placental vascular tree and assess its relevance for plastic surgery departments. Measurements of the placental vasculature and morphological characterization of 18 placentas were made. After the model was used in a basic microsurgery training laboratory session, a survey was given to nine plastic surgery residents, two microsurgeons, and one hand surgeon. In all divisions, venous diameters were larger than arterial diameters, with minimum diameters of 0.8 and 0.6 mm, respectively. The majority of the participants considered that the model faithfully reproduces a real microsurgical scenario; the consistency of the vessels and their dissection are similar in in vivo tissue. Furthermore, all the participants considered that this model could improve their surgical technique and would propose it for microsurgical training. As some of the model's disadvantages, an abundantly thick adventitia, a thin tunica media, and higher adherence to the underlying tissue were identified. The color-perfused placenta is an excellent tool for microsurgical training in plastic surgery. It can faithfully reproduce a microsurgical scenario, offering an abundance of vasculature with varying sizes similar to tissue in vivo, enhancing technical proficiency, and lowering patient error.

Analysis of Holdup Characteristics of Large and Small Bubbles in Three-Phase Fluidized Beds by using a Dynamic Gas Disengagement Method (삼상유동층에서 동력학적 기체유출 측정방법에 의한 큰 기포와 작은 기포의 체류량 특성 해석)

  • Lim, Hyun Oh;Lim, Dae Ho;Seo, Myung Jae;Kang, Yong;Jung, Heon;Lee, Ho Tae
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.605-610
    • /
    • 2011
  • Phase holdup characteristics of relatively large and small bubbles were investigated in a three-phase(gasliquid-solid) fluidized bed of which diameter was 0.105 m(ID) and 2.5 m in height, respectively. Effects of gas(0.01~0.07 m/s) and liquid velocities(0.01~0.07 m/s) and particle size($0.5{\sim}3.0{\times}10^{-3}m$) on the holdups of relatively large and small bubbles were determined. The holdups of two kinds of bubbles in three phase fluidized beds were estimated by means of static pressure drop method with the knowledge of pressure drops corresponding to each kind of bubble, respectively, which were obtained by dynamic gas disengagement method. Dried and filtered air which was regulated by gas regulator, tap water and glass bead of which density was $2500kg/m^3$ were served as a gas, a liquid and a fluidized solid phase, respectively. The two kinds of bubbles in three-phase fluidized beds, relatively large and small bubbles, were effectively detected and distinguished by measuring the pressure drop variation after stopping the gas and liquid flow into the column as a step function: The increase slope of pressure drop with a variation of elapsed time was quite different from each other. It was found that the holdup of relatively large bubbles increased with increasing gas velocity but decreased with liquid velocity. However, the holdup showed a local minimum with a variation of size of fluidized solid particles. The holdup of relatively small bubbles increased with an increase in the gas velocity or solid particle size, while it decreased slightly with an increase in the liquid velocity. The holdups of two kinds of bubbles were well correlated in terms of operating variables within this experimental conditions, respectively.

Linearity Estimation of PET/CT Scanner in List Mode Acquisition (List Mode에서 PET/CT Scanner의 직선성 평가)

  • Choi, Hyun-Jun;Kim, Byung-Jin;Ito, Mikiko;Lee, Hong-Jae;Kim, Jin-Ui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.86-90
    • /
    • 2012
  • Purpose: Quantification of myocardial blood flow (MBF) using dynamic PET imaging has the potential to assess coronary artery disease. Rb-82 plays a key role in the clinical assessment of myocardial perfusion using PET. However, MBF could be overestimated due to the underestimation of left ventricular input function in the beginning of the acquisition when the scanner has non-linearity between count rate and activity concentration due to the scanner dead-time. Therefore, in this study, we evaluated the count rate linearity as a function of the activity concentration in PET data acquired in list mode. Materials & methods: A cylindrical phantom (diameter, 12 cm length, 10.5 cm) filled with 296 MBq F-18 solution and 800 mL of water was used to estimate the linearity of the Biograph 40 True Point PET/CT scanner. PET data was acquired with 10 min per frame of 1 bed duration in list mode for different activity concentration levels in 7 half-lives. The images were reconstructed by OSEM and FBP algorithms. Prompt, net true and random counts of PET data according to the activity concentration were measured. Total and background counts were measured by drawing ROI on the phantom images and linearity was measured using background correction. Results: The prompt count rates in list mode were linearly increased proportionally to the activity concentration. At a low activity concentration (<30 kBq/mL), the prompt net true and random count rates were increased with the activity concentration. At a high activity concentration (>30 kBq/mL), the increasing rate of the prompt net true rates was slightly decreased while the increasing rate of random counts was increased. There was no difference in the image intensity linearity between OSEM and FBP algorithms. Conclusion: The Biograph 40 True Point PET/CT scanner showed good linearity of count rate even at a high activity concentration (~370 kBq/mL).The result indicates that the scanner is useful for the quantitative analysis of data in heart dynamic studies using Rb-82, N-13, O-15 and F-18.

  • PDF