• 제목/요약/키워드: Dynamic accuracy enhancement

검색결과 22건 처리시간 0.021초

Optimal Phase of Dynamic Computed Tomography for Reliable Size Measurement of Metastatic Neuroendocrine Tumors of the Liver: Comparison between Pre- and Post-Contrast Phases

  • Huh, Jimi;Park, Jisuk;Kim, Kyung Won;Kim, Hyoung Jung;Lee, Jong Seok;Lee, Jong Hwa;Jeong, Yoong Ki;Shinagare, Atul B.;Ramaiya, Nikhil H.
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1066-1076
    • /
    • 2018
  • Objective: The reliability of size measurements of liver metastases from neuroendocrine tumors (NETs) on contrast-enhanced computed tomography (CT) phases made by different readers may be hampered due to transient, variable rim enhancement in arterial phase (AP) or portal venous phase (PVP) images. We aimed to assess the reliability of tumor size measurements in pre- and post-contrast scans. Materials and Methods: The study coordinator selected target lesions according to Response Evaluation Criteria in Solid Tumors 1.1 guidelines in 44 consecutive patients with pathologically confirmed NET liver metastases. Two blinded readers measured the longest diameters of target lesions on pre-contrast, AP, and PVP images twice with a 4-week interval. Inter- and intra-observer agreements were evaluated using Bland-Altman plots and 95% limit of agreement (LOA) calculations. Results: Of the 79 target lesions (approximate mean size of 3 cm), 45 showed rim enhancement. Inter-observer agreement assessed based on LOA was highest in pre-contrast CT images (-6.1-5.7 mm), followed by PVP (-7.9-7.1 mm) and AP (-8.5-7.4 mm) images. Intra-observer agreement showed the same trend: -2.8-2.9 mm and -2.9-2.9 mm for readers 1 and 2, respectively, on pre-contrast CT, -2.8-2.9 mm and -3.0-3.2 mm, respectively, on PVP, and -3.2-4.2 mm and -3.4-3.2 mm, respectively, on AP images. Mean tumor diameters differed significantly among the phases in the following increasing order: pre-contrast CT, PVP, and AP images. Conclusion: There was better inter- and intra-observer agreement in size measurements of NET liver metastases on pre-contrast scans than on AP and PVP scans. Pre-contrast CT may be the optimal for measuring NET liver metastases if its accuracy is proven.

준능동 TMD를 이용한 메가골조구조물의 진동제어 (Vibration Control of Mega Frame Structures using a Semi-active Tuned Mass Damper)

  • 김현수;이동근
    • 한국지진공학회논문집
    • /
    • 제11권2호
    • /
    • pp.57-68
    • /
    • 2007
  • 메가골조시스템은 사용되는 구조재료를 절약하면서도 구조물의 강성을 효과적으로 높일 수 있는 장점 때문에 고층건물의 설계에 많이 사용되고 있다. 이러한 메가골조시스템이 주로 적용되고 있는 초고층건물의 구조설계에서는 횡하중에 대한 거주자의 불안감을 최소화시키는 것이 주요한 관심사중의 하나이다. 따라서 본 연구에서는 메가골조구조물의 사용성을 향상시키기 위한 방법으로 일반적인 수동 TMD의 제어성능을 개선한 준능동 TMD(STMD)를 사용하였다. 이를 위하여 TMD에서 일반적으로 사용되고 있는 수동감쇠기 대신 준능동 MR 감쇠기를 사용하여 STMD를 구성하였다. 메가골조구조물의 일반적인 유한요소해석모델은 매우 많은 수의 자유도로 구성되어 있기 때문에 원형모델을 사용하여 STMD의 제어성능을 검토하는 것은 현실적으로 불가능하다. 따라서 메가골조구조물의 동적 거동을 정확하게 표현할 수 있는 최소한의 자유도를 가진 응축모델을 행렬응축기법을 이용하여 제안하였다. 또한 일반적인 행렬응축기법의 효율성을 향상시키기 위하여 메가골조구조물의 특성을 활용한 다단계 행렬응축기법을 제안하였다. 본 연구에서 제안된 응축모델을 사용한 제어의 효율성과 정확성 및 메가골조구조물에 대한 STMD의 제어성능을 예제해석을 통하여 검증하였다.