• 제목/요약/키워드: Dynamic Insulation

검색결과 105건 처리시간 0.029초

동적 단열재의 열성능 측정에 관한 연구 (A Measurement Study of a Dynamic Insulator Thermal Performance)

  • 고선미;강은철;이의준
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.361-368
    • /
    • 2010
  • Due to the insulation and the air-tightness requirement in modern buildings have resulted NBS(New Building Syndrome) and SBS(Sick Building Syndrome) of IAQ problems. Therefore, energy efficient way of solving such IAQ issues are of major concern in these days and building industries. This paper introduces a method to improve thermal performance with a DI(Dynamic Insulation) concept. The characteristic of the dynamic insulation is that the lower U-value as the higher air velocity through the DI in a micro level. A thermal performance monitoring study has been conducted to show the energy impact of porous DI over the static insulation material. The results show that up to 45% could be improved in the case with DI compared to the conventional insulation.

동적 단열재를 적용한 건물에서의 에너지소비량 비교 분석 (Heating Power Consumption Comparison Study Between Static Insulation and Dynamic Insulation at KIER Twin Test Cell)

  • 강은철;박용대;이의준;윤태권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.919-924
    • /
    • 2008
  • Power consumption in the building thermal load could be the sum of the building fabric conduction load, building ventilation convection load and other such as radiation loss load. Dynamic Breathing Building (DBB) is the state-of-the-art to improve the wall insulation and indoor air quality(IAQ) performance as making air flow through the wall. This heat recovery type DBB contributes the power consumption saving due to the improved dynamic U-value. KIER twin test cell with static insulation(SI) and dynamic insulation(DI) at KIER was developed to test building power consumption at the real outside conditions. Then, the actual results were compared with the theory to predict the power consumption at the KIER twin test cell and introduced the building new radiation loss factor $\alpha$ to explain the difference between the both the theory and the actual case. As the results, the power consumption at the breathing DI wall building could saved 10.8% at the 2ACH(Air change per hour) compared with conventional insulation. The building radiation loss factor $\alpha$ for this test condition to calibrate the actual test was 0.55 in the test condition.

  • PDF

모의실험을 통한 완충재별 진동전달량과 동적특성과의 상관성 분석에 관한 연구 (Analysis of Correlation between the Vibration Transmissions and the Dynamic Characteristics for Floor Impact Sound Insulation Materials through Model Test)

  • 김흥식;주시웅;진필화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1425-1431
    • /
    • 2006
  • In this study, An analysis of correlation between the vibration transmissions and the dynamic characteristics for floor impact sound insulation materials through model test was carried out. As the results, the correlation coefficients between the vibration transmissions and the dynamic characteristics for floor impact sound insulation materials were over 0.8 at the heavy and light floor impact source and less dynamic stiffness was more effective in reducing the vibration transmission.

  • PDF

한국 남성용 단일의복의 앙상블 조합시의 온열특성 변화에 관한 연구 - 무풍, 풍속환경하에서 - (A Study on Changes in Thermal Performances in Ensembles Made up of Single Garments Marketed for Korean Men - In Still and Dynamic Air Conditions -)

  • 송민규;권서윤;정현미
    • 한국의류산업학회지
    • /
    • 제14권4호
    • /
    • pp.660-668
    • /
    • 2012
  • The purpose of this study is to analyze the thermal characteristics of garments marketed for Korean males and to investigate the influence of each garment on ensemble, by measuring their insulation values(clo) using thermal manikins. The results are as follows. The total insulations(clo) of ensembles for S/S seasons are between 1.46 and 2.6 clo, with the mean of 2.12 clo. The insulation in the still air condition is 1.23 clo, which means a decrease of 42% compared to the total insulation of all the component garments. The insulation of ensembles for S/S seasons in the dynamic air condition decreased by 46.8%, compared to the still air condition. The total insulation(clo) of ensembles for F/W seasons is between 3.84 and 7.36 clo with the mean of 4.74 clo. The insulation in the still air condition is 2.26 clo, which means a decrease of 53.6% compared to the total insulation of all the component garments. The insulation of ensembles for F/W seasons in the dynamic air condition decreased by 36.2%, compared to the still air condition. As the clo value of each component garment gets higher, the insulation of ensembles gets higher. Especially, the insulation of ensembles was more influenced by outer wear than inner wear. The insulation of ensembles could be predicted by the insulation of outerwear better.

동적계획법을 이용한 고온수배관의 최적보온설계에 관한 연구 (A study on the optimal design for heat insulation of hot water piping systems using a dynamic programming)

  • 유희한;하주식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.39-52
    • /
    • 1987
  • Recently, the design problem of heat insulation have been reappraised in the aspect of energy saving due to the rising trend of energy cost. For example, that design problem is increasingly requsted in the fields of accommodation air conditioning systems, hot water supply systems, cargo handling systems, district heating or cooling systems. The rational design of heat insulation of piping systems can not only improve the overall efficiency of energy transfer but also give energy saving. In this paper, the heat insulation problem of district heating systems is therefore modeled as the multi-stage decision processes, suitable for dynamic programming technique. And take the object function as the sum of heat insulation material cost involved construction cost and heat loss cost, and propose the design method to minimize the object function for overall piping systems by dynamic programing. Effectiveness of design method presented here is proved by a computer simulation.

  • PDF

풍속 존재 시 쾌적보온성 의복의 온열특성에 관한 연구 (A Study on the Insulation of Thermal Clothing Under Dynamic Air Condition)

  • 송민규;권명숙
    • 복식
    • /
    • 제58권9호
    • /
    • pp.29-37
    • /
    • 2008
  • The purpose of this study was to investigate insulation of thermal clothing under still and dynamic air conditions(with 2.1m/sec air velocity) and decrease of insulation in both conditions, to analyze correlations among them, and to estimate insulation and decrease of insulation using factors, such as fabric insulation, fabric weight, clothing weight, air permeability, and water vapor resistance. A total of 25 kinds of clothing were tested(9 types for suits, 6 types of jacket, 5 types for shirts, and 5 types for trousers). The results of this study were as follows; Thermal resistance of clothing under the dynamic air condition decreased comparing to that of clothing under still air condition in all types of clothing. Decrease in shirts was the biggest(47.5%), followed by suits(39.51%), trousers(37.48%), and jackets(34.49%) in sequence. Thermal resistance of clothing under dynamic air condition showed very high correlation(0.98, p<0.01) with that of clothing under still air condition, followed by thermal resistance of fabric(0.86, p<0.01). Decrease in thermal resistance of clothing showed the highest correlation with air permeability. It didn't show correlation with other factors. Regression analysis showed that fabric thickness would be useful factor for estimating thermal resistance of clothing and air permeability also would be useful factor for estimating decrease in thermal resistance of clothing.

바닥충격음 완충재의 동적특성에 영향을 미치는 요인 분석 (Analysis of Influence Factors on Dynamic Properties of Floor Impact Noise Insulation Materials)

  • 김흥식;주시웅;김대준;김병진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.946-949
    • /
    • 2005
  • In this paper, influence factors on dynamic properties of floor impact noise insulation materials are suggested. For this purpose measurements on the dynamic stiffness and the loss factor of resilient materials are carried out by Korea standard (KS F 2868) according to the change of density, thickness, design pattern, and composition of materials. As a result the values of dynamic stiffness was decreased at high density and thick thickness, and that of loss factor was increased at low density. For dynamic properties, the pattern of lattice and waffle type material is better than that of plat type, and the mixed composition of materials is better than the composition of double layer materials at same thickness.

  • PDF

거주공간에서 뜬바닥 구조에 사용하는 동탄성계수 측정방법 (Determination of dynamic stiffness of materials used under floating floors in dwellings)

  • 정갑철;오양기;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.945-949
    • /
    • 2002
  • This part of specifies the method for determining the dynamic stiffness of resilient materials used under floating floors. Dynamic stiffness is one of the parameters that determine the sound insulation of such floors in dwellings. This part applies to the determination of dynamic stiffness per unit area of resilient materials with smooth surfaces used in a continuous layer under floating floors in dwellings

  • PDF

거주공간에서 뜬바닥 구조에 사용하는 동탄성계수 측정방법 (Determination of dynamic stiffness for materials used under floating floors in dwellings)

  • G. C. Jeong;Y. K. Oh;Kim, S. W.
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.392.1-392
    • /
    • 2002
  • This part of specifies the method for determining the dynamic stiffness of resilient materials used under floating floors. Dynamic stillness is one of the parameters that determine the sound insulation of such floors in dwellings. This part applies to the determination of dynamic stiffness per unit area of resilient materials with smooth surfaces used in a continuous layer under floating floors in dwellings.

  • PDF

동적 시정수 기반 고성능 절연 저항 계산 기법 (Dynamic Time Constant Based High-Performance Insulation Resistance Calculation Method)

  • 손기범;홍종필
    • 한국정보통신학회논문지
    • /
    • 제24권8호
    • /
    • pp.1058-1063
    • /
    • 2020
  • 본 논문에서는 IT 접지 시스템의 감전 및 화재사고 방지를 위한 새로운 절연 저항 계산 기법을 소개한다. 최근 신재생 에너지와 에너지 저장 장치의 확대 보급으로 태양광 발전 시장이 급속하게 성장하고 있으나 절연이 파괴되어 화재사고가 빈번히 발생함에 따라 IT 접지 방식에도 절연 저항 상태를 감시하는 장치가 필수적으로 요구되고 있다. 제안하는 절연 저항 계산 기법은 기존의 고정된 시정수곱 계수기반의 알고리즘에 비해 절연 임피던스의 조건에 따라 동적시정수곱계수를 적용함으로써 넓은 절연 저항 범위에서 빠른 응답 시간과 높은 정확도를 갖는다. 제안하는 동적 시정수 기반 절연 저항 계산 기법은 기존의 방법에 비해 최대 응답 시간은 39.29초, 오차율은 20.11%를 개선시키는 효과를 보였다.