• Title/Summary/Keyword: Dynamic Inflow

Search Result 98, Processing Time 0.021 seconds

Development and Application of Multiple Box Water Quality Model for Estuary Reservoirs (담수호 Multiple Box 수질모형의 개발과 적용)

  • 임종환;권순국
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.31 no.4
    • /
    • pp.111-122
    • /
    • 1989
  • A multiple box model which is suitable for the prediction of water quality in shallow lakes with active mixing is a water quality model expected to be used widely in estuary reservoir. In this study, a multiple box water quality model for estuary reservoirs (MBQER) was developed arid the applicability of the MBQER was tested by applying data obtained from Asan-estuary reservoir. The results of this study can be summarized as follows. 1. The MBQER, dynamic water quality model, was developed to estimate 10-day water qualities of estuary reservoirs. For the proper analysis and the application of hydraulics needed to build a model, lake hydraulics was simplified by condisering only hydrological inflow and lake mixing currents. The box division in the MBQER is longitudinal one dimension for upper and middle part, and two layers for lower part of the reservoir. 2. The methods of box division for the multiple box model were ekamined and applied to Asan-estuary reservoir. For determining the number of boxes, Pe number and Pk number were used. In case of three boxes, the error by the model simplification would be estimated about 5 % Therefore, in Asan reservoir, the proper number of boxes was three. 3. The MBQER was calibrated and verified using measured data in Asan-estuary reservoir from 1986 to 1988. The Root Mean Squares(RMS) for the differences between measured data and simulated results by the MBQER were 1.10$^{\circ}$C C for water temperature, 75.8mg/1 for salinity, 0.082mg/1 for total-phosphorus showing good estimations. 4. Through the simulation of water temperature and salinity by the MBQER, the exchange flow and the mixing coefficients for the estuary lake were determined. As a result of simulation, the horizontal mixing coefficients in Asan-estuary reservoir were in the range of 1.07X 105 to 1.12X 105 cm$^2$/sec and vertical mixing coefficient was 2.90X 10-1 cm$^2$/sec.

  • PDF

Prediction of boil-off gas and boil-off rate in cargo tank of NGH carrier

  • Kang, Ho-Keunn;Kim, Dongeum;Kim, You-Taek;Park, Jung-Dae;Kang, Shin-Baek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.10
    • /
    • pp.1002-1010
    • /
    • 2015
  • Natural gas hydrates are newly emerging as an environment-friendly source of energy to substitute for fossil fuels in the 21stcentury.NGHs are reported to holds much amounts of natural gas (up to 182 standard volumes of gas per volume of hydrate); they are easy to store and safe to carry at about minus 20 degree Celsius under atmospheric pressure because of the self-preservation phenomenon of gas hydrates. The transporting method by gas-ice-hydrate ship carriers has been introduced and developed by a variety of industry and research institutions. Our team has been conducted to develop NGH total systems, including a breakthrough NGH carrier for sea transportation, since 2011. The NGH pellet carrier does not require a separate cooling system for cargo, and the initial temperature is maintained through insulation of the cargo tanks throughout the transport to the final destination. The heat conducted from the exterior and passing through the insulation material of the hull should be cut off as much as possible, but heat inflow inside the cargo tank from an external source is inevitable during transport. In this study, the heat transfer in a cargo tank of a 115K NGH carrier was analyzed through simulation with a commercial CFD code to estimate the boil-off gas/boil-off rate on the developed carrier and understand major hazards that could significantly impact the safety of the vessel.

The Performance Assessment of Special Observation Program (ProbeX-2009) and the Analysis on the Characteristics of Precipitation at the Ulleungdo (울릉도 특별관측 수행평가 및 강수특성 분석)

  • Kim, Ki-Hoon;Kim, Yeon-Hee;Kim, Do-Woo;Chang, Dong-Eon
    • Atmosphere
    • /
    • v.21 no.2
    • /
    • pp.185-196
    • /
    • 2011
  • The performance assessment in radiosonde observation on the special observation program (ProbeX-2009) is performed and the characteristics of precipitation using Auto Weather System (AWS) and radiosonde data in 2009 at the Ulleungdo are investigated. The launching time, observation time, and maximum altitude of radiosonde are satisfied with the regulation from Korea Meteorological Administration (KMA) and World Meteorological Organization (WMO) but the duration of observational time of radiosonde is much shorter than that of the ProbeX-2007 because the altitude of launching site is higher than others in 2007. From the analysis of trajectories of radiosonde, most radiosondes at the Ulleungdo tend to move into the east because the westerly prevail at the middle latitude. However, when the Okhotsk high is expanded to the Korean peninsula and the north-westerly winds strengthen over the East Sea as the subtropical high is retreated, radiosonde tends to move into the south-west and south-east, respectively. Maximum distance appears at the end of observation level before May but the level of maximum distance is changed into 100 hPa after June because the prevailing wind direction is reversed from westerly to easterly at the stratosphere during summer time. The condition of precipitation was more correlated with the dynamic instability except Changma season. Precipitation in 2009 at the Ulleungdo occurred under the marine climate so that total precipitation amounts and precipitation intensity were increased and intensified during nighttime. The local environment favorable for the precipitation during nighttime was while the wind speed at the surface and the inflow from the shoreline were strengthened. Precipitation events also affected by synoptic condition but the localized effect induced by topography was more strengthened at the northern part of Ulleungdo.

Analysis of the Water Temperature Stratification-Maintaining Conditions Using CFD in Case of Intake of Deep, Low-Temperature Water (댐의 심층저온수 취수시 수온 성층화 유지 조건에 대한 CFD를 이용한 분석)

  • Lee, Jin-Sung;Cho, Soo;Sim, Kyung-Jong;Jang, Moon-Soung;Sohn, Jang-Yeul
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.31-38
    • /
    • 2009
  • This study was conducted to forecast inner water temperature strata change by extracting deep water from a dam. For the methodology, the scope wherein the balance between the volume of low-temperature water intake through the virtual water intake opening as installed within the stored water area and the volume of water intake from the surrounding area is not destroyed was calculated through the CFD simulation technique using the computational fluid dynamics(CFD) interpretation method. This study suggested a supplementary method(diffuser) to avoid destroying the water temperature strata, and the effect was reviewed. In case of intake of the same volume, when the velocity of flow of water intake is reduced by increasing the pipe diameter, the destruction of water temperature strata can be minimized. When the area(height) where the intake of water is possible is low, a diffuser for interrupting the vertical direction inflow should be installed to secure favorable water intake conditions in case of water intake on the upper part. This study showed that there was no problem if the intake-enabled, low-temperature area was secured approximately 10m from the bottom when the scope that does not destroy the water temperature strata in case of water intake was forecast using the regression formula.

Numerical Study on Submersible Pumps with a Vortex Reduction Function (와류저감기능이 적용된 수중펌프에 관한 수치적 연구)

  • Ahn, Deog-Inn;Kim, Hong-gun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.83-92
    • /
    • 2019
  • A pump is considered to be submersible when a motor and a pump are integrated and operate while submerged in water. Submersible pumps mainly function as rejection pumps to prevent foods in densely populated areas, as cold water circulation pumps in large power plants, as pumps to supply irrigation water, as drainage pumps to prevent flooding of agricultural lands, as water supply intake pumps, and as inflow pumps for sewage treatment. The flow in such turbomachines (submersible pumps) inevitably involves various eddy currents. Since it is almost impossible to accurately grasp the complex three-dimensional flow structure and characteristics of a rotating turbomachine through actual testing, three-dimensional numerical analysis using computational fluid dynamics techniques measuring the flow field, velocity, and the pressure can be accurately predicted. In this study, the shape of the impeller was developed to reduce vibration and noise. This was done by increasing the efficiency of the existing submersible pump and reducing turbulence. In order to evaluate the pump's efficiency and turbulence reduction, we tried to analyze the flow using ANSYS Fluent V15.0, a commercial finite element analysis program. The results show that the efficiency of the pump was improved by 4.24% and the Reynolds number was reduced by 15.6%. The performance of a developed pump with reduced turbulence, vibration, and noise was confirmed.

A Study for Ameliorating Design Guidelines to Vitalize Privately Owned Public Space(POPS) (공개공지 조성지침 시대별 특징 및 개선방안 연구)

  • Kim, Do-yeon;Choi, Yun-kyung
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.3
    • /
    • pp.105-116
    • /
    • 2018
  • POPS(Privately Owned Public Spaces) is one of the major component that vitalize the city by private sectors providing open-spaces to the public. It holds great significances and possibilities within CBD(Central Business District) which lack open-space and green-space. Despite of its importance, a large number of problems such as deficient accessibility for the public and being unpractical from constructing only with formality occur in existing POPS. POPS should be for both owners and public because it is a public space located within a private estate. To vitalize POPS, functions like "diversity", "accessibility and connectivity", and "usability" are essential. Providing diverse types of spaces makes dynamic city, and the spaces must have easy access by public and variety of functions. Managements by diverse types of POPS are necessary to improve availability and to provides suitable spaces. To make diverse types of POPS, advanced classifications of type and clear criteria are required. From aspect of accessibility and connectivity, firstly detailed instructions for the arrangement are necessary for reinforcement. Specific research on means of connection such as how many faces of POPS should adjoin streets and in which direction it should be facing should be applied. Purposes of POPS must be specified depending on the type of POPS. By connecting adjacent buildings with POPS, one of the main principal of vitalizing POPS, inflow of people can be increased. Accordingly, improvements of design guidelines in "diversity", "accessibility and connectivity", and "usability" can be suggested to vitalize POPS. With these concerns in mind, this paper analyzes problems of current Seoul POPS guidelines with three aspects.

Case Study of Moving up the Charts in K-pop : Focusing on Brave Girls' 「Rollin'」 (K-pop 음원 역주행에 대한 사례 분석 : 브레이브걸스(Brave Girls)의 「롤린(Rollin')」을 중심으로)

  • Jung, Seung-Hwan
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.5
    • /
    • pp.69-83
    • /
    • 2021
  • To understand 'Moving up the charts' as a dynamic phenomenon in the K-pop entertainment industry, this study specifically analyzed the 'Moving up the charts' of 「Rollin'」 sung by 'Brave Girls'. First, the context and process related to 「Rollin'」 were described in detail, and the performance as a sound source and business were described. Subsequently, six factors were analyzed and presented as causes for 'Moving up the charts': 'Existence of specific possible triggers', 'Attractions of content itself', 'Inflow of new male fans', 'Turning weaknesses into strengths as idol', 'Psychological empathy with stories of real group' and 'Fast response and communication of agency'. Due to the influence of 'Moving up the charts', two changes were presented: 'Expansion of popularity and interest and expansion beyond songs' and 'Forming a consumer group with high purchasing power'. Through this, this study discussed the meaning, role, and possibility of 'Moving up the charts' in the K-pop entertainment industry. In the future, it will be necessary to recognize 'Moving up the charts' in the music market as a remarkable phenomenon, and to understand the importance of new idol consumer class as well as the use of related media such as YouTube.

Nonlinear Modeling and Application of PI Control on Pre-cooling Session of a Carbon Dioxide Storage Tank at Normal Temperature and Pressure (상온 상압의 이산화탄소 저장용 탱크를 위한 예냉과정의 비선형 모델링 및 비례-적분 제어 적용)

  • Lim, Yu Kyung;Lee, Seok Goo;Dan, Seungkyu;Ko, Min Su;Lee, Jong Min
    • Korean Chemical Engineering Research
    • /
    • v.52 no.5
    • /
    • pp.574-580
    • /
    • 2014
  • Storage tanks of Carbon dioxide ($CO_2$) carriers utilized for the purpose of carbon capture and storage (CCS) into subsea strata have to undergo a pre-cooling session before beginning to load cryogenic liquid cargos in order to prevent physical and thermal deterioration of tanks which may result from cryogenic $CO_2$ contacting tank walls directly. In this study we propose dynamic model to calculate the tank inflow of $CO_2$ gas injected for precooling process and its dynamic simulation results under proportional-integral control algorithm. We selected two cases in which each of them had one controlled variable (CV) as either the tank pressure or the tank temperature and discussed the results of that decision-making on the pre-cooling process. As a result we demonstrated that the controlling instability arising from nonlinearity and singularity of the mathematical model could be avoided by choosing tank pressure as CV instead of tank temperature.

Sewer Decontamination Mechanism and Pipe Network Monitoring and Fault Diagnosis of Water Network System Based on System Analysis (시스템 해석에 기초한 하수관망 오염 매카니즘과 관망 모니터링 및 이상진단)

  • Kang, OnYu;Lee, SeungChul;Kim, MinJeong;Yu, SuMin;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.980-987
    • /
    • 2012
  • Nonpoint source pollution causes leaks and overtopping, depending on the state of the sewer network as well as aggravates the pollution load of the aqueous water system as it is introduced into the sewer by wash-off. According, the need for efficient sewer monitoring system which can manage the sewage flowrate, water quality, inflow/infiltration and overflow has increased for sewer maintenance and the prevention of environmental pollution. However, the sewer monitoring is not easy since the sewer network is built in underground with the complex nature of its structure and connections. Sewer decontamination mechanism as well as pipe network monitoring and fault diagnosis of water network system on system analysis proposed in this study. First, the pollution removal pattern and behavior of contaminants in the sewer pipe network is analyzed by using sewer process simulation program, stormwater & wastewater management model for expert (XP-SWMM). Second, the sewer network fault diagnosis was performed using the multivariate statistical monitoring to monitor water quality in the sewer and detect the sewer leakage and burst. Sewer decontamination mechanism analysis with static and dynamic state system results showed that loads of total nitrogen (TN) and total phosphorous (TP) during rainfall are greatly increased than non-rainfall, which will aggravate the pollution load of the water system. Accordingly, the sewer outflow in pipe network is analyzed due to the increased flow and inflow of pollutant concentration caused by rainfall. The proposed sewer network monitoring and fault diagnosis technique can be used effectively for the nonpoint source pollution management of the urban watershed as well as continuous monitoring system.

Oxidative Degradation of PCE/TCE Using $KMnO_4$ in Aqueous Solutions under Steady Flow Conditions (유동조건에서 $KMnO_4$도입에 따른 수용액중 PCE/TCE의 산화분해)

  • Kim, Heon-Ki;Kim, Tae-Yun
    • Economic and Environmental Geology
    • /
    • v.41 no.6
    • /
    • pp.685-693
    • /
    • 2008
  • The rates of oxidative degradation of perchloroethene (PCE) and trichloroethene (TCE) using $KMnO_4$ solution were evaluated under the flow condition using a bench-scale transport experimental setup. Parameters which are considered to affect the reaction rates tested in this study were the contact time (or retention time), and the concentration of oxidizing agent. A glass column packed with coarse sand was used for simulating the aquifer condition. Contact time between reactants was controlled by changing the flow rate of the solution through the column. The inflow concentrations of PCE and TCE were controlled constant within the range of $0.11{\sim}0.21\;mM$ and $1.3{\sim}1.5\;mM$, respectively. And the contact time was $14{\sim}125$ min for PCE and $15{\sim}36$ min for TCE. The $KMnO_4$ concentration was controlled constant during experiment in the range of $0.6{\sim}2.5\;mM$. It was found that the reduction of PCE and TCE concentrations were inversely proportional to the contact time. The exact reaction order for the PCE and TCE degradation reaction could not be determined under the experimental condition used in this study. However, the estimated reaction rate constants assuming pseudo-1st order reaction agree with those reported based on batch studies. TCE degradation rate was proportional to $KMnO_4$ concentration. This was considered to be the result of using high inflow concentrations of reactant, which might be the case at the vicinity of the source zones in aquifer. The results of this study, performed using a dynamic flow system, are expected to provide useful information for designing and implementing a field scale oxidative removal process for PCE/TCE-contaminated sites.