• 제목/요약/키워드: Dynamic Effect of Gas

검색결과 186건 처리시간 0.029초

삼중효용 LiBr/물 흡수식 냉방기의 사이클 시뮬레이션 (Cycle simulation of a triple effect LiBr/water absorption chiller)

  • 조광운;정시영;정은수
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.79-87
    • /
    • 1998
  • Basic design of a 50USRT(175㎾) triple effect absorption chiller driven by hot gas has been carried out for both parallel and series flow cycles. Parallel flow cycle showed higher COP, however, the temperature in the generator was also higher than that in series flow cycle. Dynamic operation behavior of a parallel flow system at off-design conditions, such as the change in heat transfer medium temperature or the construction change of the system components, has been investigated in detail. It was found that the cooling capacity was seriously decreased by reducing hot gas flow rate and UA-value in the high temperature generator. However, the system COP was improved, because thermal load in the system components was reduced. The COP and the cooling capacity was found to be improved as cooling water temperature decreased or chilled water temperature increased. The optimum ratio of solution distribution could be suggested by considering the COP, the cooling capacity and the highest temperature in the system, which is critical for corrosion.

  • PDF

Parametric Investigation of BOG Generation for Ship-to-Ship LNG Bunkering

  • Shao, Yude;Lee, Yoon-Hyeok;Kim, You-Taek;Kang, Ho-Keun
    • 해양환경안전학회지
    • /
    • 제24권3호
    • /
    • pp.352-359
    • /
    • 2018
  • As a fuel for ship propulsion, liquefied natural gas (LNG) is currently considered a proven and reasonable solution for meeting the IMO emission regulations, with gas engines for the LNG-fueled ship covering a broad range of power outputs. For an LNG-fueled ship, the LNG bunkering process is different from the HFO bunkering process, in the sense that the cryogenic liquid transfer generates a considerable amount of boil-off gas (BOG). This study investigated the effect of the temperature difference on boil-off gas (BOG) production during ship-to-ship (STS) LNG bunkering to the receiving tank of the LNG-fueled ship. A concept design was resumed for the cargo/fuel tanks in the LNG bunkering vessel and the receiving vessel, as well as for LNG handling systems. Subsequently, the storage tank capacities of the LNG were $4,500m^3$ for the bunkering vessel and $700m^3$ for the receiving vessel. Process dynamic simulations by Aspen HYSYS were performed under several bunkering scenarios, which demonstrated that the boil-off gas and resulting pressure buildup in the receiving vessel were mainly determined by the temperature difference between bunkering and the receiving tank, pressure of the receiving tank, and amount of remaining LNG.

Transmission Path Analysis of Noise and Vibration in a Rotary Compressor by Statistical Energy Analysis

  • Hwang, Seon-Woong;Jeong, Weui-Bong;Yoo, Wan-Suk;Kim, Kyu-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제18권11호
    • /
    • pp.1909-1915
    • /
    • 2004
  • The hermetic rotary compressor is one of the most important components of an air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration occurs due to gas pulsation during the compression process and to unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify their sources and transmission path and effectively control them. Many approaches have been tried in order to identify the noise transmission path of a compressor. However, identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this study, the statistical energy analysis has been used to trace the energy flow in the compressor and to identify the transmission paths from the noise source to the exterior sound field.

증기발전 시스템의 과도상태 특성 해석 (Analysis of Transient Characteristics of a Steam Power Plant System)

  • 박근한;김동섭;노승탁
    • 대한기계학회논문집B
    • /
    • 제24권7호
    • /
    • pp.967-975
    • /
    • 2000
  • Transient characteristics of a boiler and turbine system for a steam power plant are simulated. One-dimensional unsteady models are introduced for each component. An interaction between boiler and turbine and a control of the water level in the drum are taken into account. Transient responses of the system to the variations of main system variables such as fuel and air flow rate, cooling water injection rate at the attemperator, gas recirculation rate at the furnace and opening of the turbine control valve are examined. Effect of fluid inertia and tube wall thermal inertia on predicted dynamic behavior is investigated.

$SF_6$ gas가 초고압 차단기 내에서 Arc Plasma에 미치는 영향 (Influence of $SF_6$ Gas On An Arc Plasma In UHV Circuit Breaker)

  • 최경철;황기웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.278-282
    • /
    • 1987
  • Computational and theoritical investigations of an arc plasma have been made for the design of a circuit breaker. Modeling of an arc plasma used to be very involved and difficult because of the many variables and factors, In this paper, the dynamic behavior of an arc plasma is investigated by solving the MHD equations. Comparing an $SF_6$-blast arc with a non-blast arc, it has been found that the effect of gas-blast has a great influence on density rather than temperature.

  • PDF

SEA에 의한 회전 압축기의 소음 진동 해석 (Noise and Vibration Analysis of Rotary Compressor by SEA)

  • 황선웅;안병하;정의봉;김규환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.964-968
    • /
    • 2003
  • Hermetic rotary compressor is one of the most Important components for air conditioning system since it has a great effect on both the performance and the noise and vibration of He system. Noise and vibration of rotary compressor is occurred due to gas pulsation during compression process and unbalanced dynamic force. In order to reduce noise and vibration. it is necessary to identify sources of noise and vibration and effectively control then. Many approaches have been tried to identify noise sources of compressor. However, compressor noise source identification has proven to be difficult since the characteristics of compressor noise are complicated due to the interaction of the compressor parts and gas pulsation. In this work, Statistical Energy Analysis has been used to trace the energy flow in the compressor and identify transmission paths from the noise source to the sound field.

  • PDF

2단 튜브형 가열로 반응기에 의한 초미세 SiO2 입자의 제조 및 증착 연구 (A Study on Ultrafine SiO2 Particles Generation and Deposition by 2-Stage Tube Furnace Reactor)

  • 유수종;김교선
    • 산업기술연구
    • /
    • 제17권
    • /
    • pp.233-239
    • /
    • 1997
  • The effects of preheating the gas stream on deposition characteristics of ultrafine $SiO_2$ particles were investigated theoretically. The model equations such as mass and energy balance equations and aerosol dynamic equations were solved to predict the particle growth and deposition. The gas temperatures, $SiCl_4$ concentrations, $SiO_2$ particle volumes, $SiO_2$ particle sizes and deposition efficiencies of $SiO_2$ particles were calculated for various preheating temperatures. As the preheater setting temperature increases, the $SiO_2$ particle size distribution becomes more uniform, because the effect of $SiCl_4$ diffusion decreases.

  • PDF

가스터빈 부분 예혼합 연소기에서 당량비 섭동에 대한 화염전달함수 모델링 (Flame Transfer Function Modeling in a Gas Turbine Partially-premixed Combustor with Equivalence Ratio Modulation)

  • 김지환;김대식
    • 한국분무공학회지
    • /
    • 제22권2호
    • /
    • pp.55-61
    • /
    • 2017
  • This study has investigated the relationship between heat release fluctuations and the flow perturbations in a partially premixed gas turbine combustor using a commercial CFD code. Special focus of the current work is placed on the effect of equivalence ratio on the flame dynamics in a partially-premixed system. As the first step for this combustion dynamics study in the non-perfectly premixed combustor, flame behaviors are modeled and then compared with measured results under both steady and unsteady conditions. The calculated results of the flame transfer function with equivalence ratio fluctuation are found to well capture the main qualitative characteristics of the combustion dynamics for the partially-premixed flames.

조리에 따른 한국산 짚신나물(Agrimonia Japonica)의 휘발성 풍미 성분의 변화 (Changes volatile flavor components of Korean Agrimonia Japonica by cooking)

  • 이혜정;이경희;구성자
    • 한국식품조리과학회지
    • /
    • 제11권2호
    • /
    • pp.122-125
    • /
    • 1995
  • 짚신나물의 생시료와 가열시료의 휘발성 풍미성분을 분석하기 위해 dynamic head space 방법으로 정유 성분을 분리한 다음 GC 및 GC-MS를 이용하여 성분을 확인하였다. 생시료에서는 탄화수소류 16종, 알콜류가 7종, 에스터류가 4종, 알데히드와 케톤이 각각 1종씩 그리고 벤젠 화합물이 7종 확인되었다. 가열된 시료에서는 탄화수소류만이 6종이 확인되었다.

  • PDF

동섬 및 편섬된 두 수형원판 사이의 환상유로에서의 복사와 자연대류간의 상호작용 (Radiation - Natural Convection Interactions in Concentric and Eccentric Horizontal Annuli)

  • 한조영;백승욱
    • 대한기계학회논문집B
    • /
    • 제22권12호
    • /
    • pp.1796-1804
    • /
    • 1998
  • A numerical investigation has been performed to discuss the radiation-affected steady-laminar natural convection induced by a hot inner cylinder under a large temperature difference in the annuli filled with a gray gas. To examine the effects of thermal radiation on thermo-fluid dynamic behaviors in the eccentric geometry, the generalized body-fitted coordinate system is introduced while the finite volume method (FVM) is used for solving the radiative transport equation. After validating the numerical results for the case without radiation, the detailed radiation effect has been discussed. Based on the results of this study, when there exists a large temperature difference between two cylinders, the existence of radiatively participating medium is found to incur a distinct difference in fluid dynamic as well as thermal behavior.