• Title/Summary/Keyword: Dynamic Component

Search Result 1,096, Processing Time 0.03 seconds

Direction-Embedded Branch Prediction based on the Analysis of Neural Network (신경망의 분석을 통한 방향 정보를 내포하는 분기 예측 기법)

  • Kwak Jong Wook;Kim Ju-Hwan;Jhon Chu Shik
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.42 no.1
    • /
    • pp.9-26
    • /
    • 2005
  • In the pursuit of ever higher levels of performance, recent computer systems have made use of deep pipeline, dynamic scheduling and multi-issue superscalar processor technologies. In this situations, branch prediction schemes are an essential part of modem microarchitectures because the penalty for a branch misprediction increases as pipelines deepen and the number of instructions issued per cycle increases. In this paper, we propose a novel branch prediction scheme, direction-gshare(d-gshare), to improve the prediction accuracy. At first, we model a neural network with the components that possibly affect the branch prediction accuracy, and analyze the variation of their weights based on the neural network information. Then, we newly add the component that has a high weight value to an original gshare scheme. We simulate our branch prediction scheme using Simple Scalar, a powerful event-driven simulator, and analyze the simulation results. Our results show that, compared to bimodal, two-level adaptive and gshare predictor, direction-gshare predictor(d-gshare. 3) outperforms, without additional hardware costs, by up to 4.1% and 1.5% in average for the default mont of embedded direction, and 11.8% in maximum and 3.7% in average for the optimal one.

A Case Study on the Data Processing to Enhance the Resolution of Chirp SBP Data (Chirp SBP 자료 해상도 향상을 위한 전산처리연구)

  • Kim, Young-Jun;Kim, Won-Sik;Shin, Sung-Ryul;Kim, Jin-Ho
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.4
    • /
    • pp.289-297
    • /
    • 2011
  • Chirp sub-bottom profilers (SBP) data are comparatively higher-resolution data than other seismic data and it's raw signal can be used as a final section after conducting basic filtering. However, Chirp SBP signal has possibility to include various noise in high-frequency band and to provide the distorted image for the complex geological structure in time domain. This study aims at the goal to establish the workflow of Chirp SBP data processing for enhanced image and to analyze the proper parameters for the domestic continental shelf. After pre-processing, we include the dynamic S/N filtering to eliminate the high-frequency component noise, the dip scan stack to enhance the continuity of reflection events and finally the post-stack depth migration to correct the distorted structure on the time domain sections. We demonstrated our workflow on the data acquired by domestically widely used equipments and then we could obtain the improved seismic sections of depth domain. This workflow seems to provide the proper seismic section to interpretation when applied to data processing of Chirp SBP that are largely used for domestic acquisition.

An experimental study on the dynamic tooth movement of two molar uprighting springs by calorific machine (두 종류의 구치직립 스프링 사용시 저항원 및 근심경사치의 동적인 치아이동 양상에 관한 연구)

  • Chun, Youn-Sic;Row, Joon
    • The korean journal of orthodontics
    • /
    • v.30 no.3 s.80
    • /
    • pp.273-285
    • /
    • 2000
  • The aim of this investigation was to evaluate the differences of two canti-leyer springs by using a new simulation system. This was done using a Calorific machine that compared iron uprighting spring and root uprighting spring. The Calorific machine was designed to allow observation of the whole process of tooth moving, and is composed of three parts(a temperature regulating system, electro-thermodynamic teeth, and an artificial alveolar bone component). The experiment of both mechanics were repeated five times and measured two times. The intra-examiner agreement and inlet-examiner agreement were $96.54\%\;and\;95.73\%$ and these data were statistically tested by paired t-test. The obtained results were as follows. 1. Distal and buccal movement of the anchor teeth were observed greater in the root uprighting spring than the crown uprighting spring. 2. Crown uprighting spring showed distal movement of the crown of lower second molar for 3.29mm but root uprighting spring showed only 1.68mm. 3. Crown uprighting spring exhibited forward movement of mesial and distal root of the lower second molar for 3.91mm, 3.60mm but the root uprighting spring showed 6.76mm, 6.26mm.

  • PDF

Quality Characteristics of the Vaporized Liquid of Water-boiled Pine Needle (솔잎 열수 증류액의 품질특성)

  • Lee, Hyo-Jin;Cui, Cheng-Bi;Choi, Hyung-Taek;Kim, Soo-Hyun;Ham, Young-An;Lee, Deuk-Sik;Ham, Seung-Shi
    • Food Science and Preservation
    • /
    • v.12 no.2
    • /
    • pp.107-111
    • /
    • 2005
  • We investigated the quality of vaporized liquid of water-boiled pine needle in the aspects of drinking conformity and aroma characteristics. As a result, there was no hazardous component in the assessment for 45 types of ingredients. Especially, inorganic components such as arsenic (As), lead (Pb), mercury (Hg), and cadmium (Cd) which are harmful to human body were not detected. Additionally, we observed that other ingredients were present within the standard level suitable for drinking. The total 34 volatile components of the vaporized liquid of water-boiled pine needle were identified by dynamic head-space method. Fenchol, bomeol $\beta-fenchyl$ alcohol and bomyl acetate were the major volatiles and composed of 6.7, 13.1, 26.6 and $16.2\%$ of total volatiles, respectively. In addition, the alcohols and aldehydes were the prominent ingredients of which the contents showed comparatively high.

Seismic Behavior and Estimation for Base Isolator Bearings with Self-centering and Reinforcing Systems (자동복원 및 보강 시스템과 결합된 면진받침의 지진거동과 평가)

  • Hu, Jong Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1025-1037
    • /
    • 2015
  • Flexible base isolation bearings that separate superstructure from ground have been widely used in the construction field because they make a significant contribution to increasing the fundamental period of the structure, thereby decreasing response acceleration transmitted into the superstructure. However, the established bearing devices installed to uphold the whole building give rise to some problems involved with failure and collapse due to lack of the capacity as modern structures are getting more massive and higher. Therefore, this study suggests new isolation bearings assembled with additional restrainers enabled to reinforcing and recentering, and then evaluates their performance to withstand the seismic load. The superelastic shape memory alloy (SMA) bars are installed into the conventional lead-rubber bearing (LRB) devices in order to provide recentering forces. These new systems are modeled as component spring models for the purpose of conducting nonlinear dynamic analyses with near fault ground motion data. The LRB devices with steel bars are also designed and analyzed to compare their responses with those of new systems. After numerical analyses, ultimate strength, maximum displacement, permanent deformation, and recentering ratio are compared to each model with an aim to investigate which base isolation models are superior. It can be shown that LRB models with superelastic SMA bars are superior to other models compared to each other in terms of seismic resistance and recentering effect.

High Resolution Time Resolved Contrast Enhanced MR Angiography Using k-t FOCUSS (k-t FOCUSS 알고리듬을 이용한 고분해능 4-D MR 혈관 조영 영상 기법)

  • Jung, Hong;Kim, Eung-Yeop;Ye, Jong-Chul
    • Investigative Magnetic Resonance Imaging
    • /
    • v.14 no.1
    • /
    • pp.10-20
    • /
    • 2010
  • Purpose : Recently, the Recon Challenge at the 2009 ISMRM workshop on Data Sampling and Image Reconstruction at Sedona, Arizona was held to evaluate feasibility of highly accelerated acquisition of time resolved contrast enhanced MR angiography. This paper provides the step-by-step description of the winning results of k-t FOCUSS in this competition. Materials and Methods : In previous works, we proved that k-t FOCUSS algorithm successfully solves the compressed sensing problem even for less sparse cardiac cine applications. Therefore, using k-t FOCUSS, very accurate time resolved contrast enhanced MR angiography can be reconstructed. Accelerated radial trajectory data were synthetized from X-ray cerebral angiography images and provided by the organizing committee, and radiologists double blindly evaluated each reconstruction result with respect to the ground-truth data. Results : The reconstructed results at various acceleration factors demonstrate that each components of compressed sensing, such as sparsifying transform and incoherent sampling patterns, etc can have profound effects on the final reconstruction results. Conclusion : From reconstructed results, we see that the compressed sensing dynamic MR imaging algorithm, k-t FOCUSS enables high resolution time resolved contrast enhanced MR angiography.

MR Findings of Papillary Neoplasms of the Breast (유두 종양의 자기공명 영상소견)

  • Jo, Yeseul;Kim, Sung Hun;Kang, Bong Joo;Choi, Byung Gil
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.43-51
    • /
    • 2014
  • Purpose : To review MR imaging finding of papillary lesion identified as additional suspicious lesion on MR image in women with biopsy-proven breast cancer and to evaluate upgrading rates after subsequent surgical histopathological diagnosis. Materials and Methods: Among 1729 preoperative MR image of women with biopsy proven breast cancer, US-guided CNB-proven 22 papillary lesions from 21 patients, which showed additional suspicious contrast enhancement other than index cancer on MR image, were subjected to the study. Some of these lesions underwent surgery, thus the comparisons between the histopathologic results were able to be compared to the results of US-guided CNB. Also retrospective analysis was done for MR findings of these lesions by BI-RADS MRI lexicon. Results: On MR imaging, 8 mass lesions, 7 non-mass lesions, 7 focus lesions were detected. All of the focus lesion (100%, 7/7) was diagnosed as benign lesion and showed plateau and washout pattern in dynamic MR image. After excisional biopsy, one of 9 benign papilloma (11.1%), 3 of 3 papillary neoplasm with atypia component (100%), 3 of 5 papillary neoplasm (60%) were upgraded to malignancy such as ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC), invasive lobular carcinoma (ILC). Conclusion: The MR images of papillary lesions diagnosed by US-guided CNB exhibit no significant differences between malignancy and benign lesion. Also 41.2% of the lesion (7/17) was upgraded after subsequent surgery. Thus all of the papillary lesions require excisional biopsy for definite diagnosis and the MR imaging, it's just not enough by itself.

Design and Implementation of Distributed QoS Management Architecture for Real-time Negotiation and Adaptation Control on CORBA Environments (CORBA 환경에서 실시간 협약 및 작응 제어를 위한 분사 QoS 관리 구조의 설계 및 구현)

  • Lee, Won-Jung;Shin, Chang-Sun;Jeong, Chang-Won;Joo, Su-Chong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.1C
    • /
    • pp.21-35
    • /
    • 2002
  • Nowadays, in accordance with increasing expectations of multimedia stream service on the internet, a lot of distributed applications are being required and developed. But the models of the existing systems have the problems that cannot support the extensibility and the reusability, when the QoS relating functions are being developed as an integrated modules which are suited on the centralized controlled specific-purpose application services. To cope with these problems, it is suggested in this paper to a distributed QoS management system on CORBA, an object-oriented middleware compliance. This systems we suggested can provides not only for efficient control of resources, various service QoS, and QoS control functions as the existing functions, but also QoS control real-time negotiation and dynamic adaptation in addition. This system consists of QoS Control Management Module(QoS CMM) in client side and QoS Management Module(QoS MM) in server side, respectively. These distributed modules are interfacing with each other via CORBA on different systems for distributed QoS management while serving distributed streaming applications. In phase of design of our system, we use UML(Unified Modeling Language) for designing each component in modules, their method calls and various detailed functions for controlling QoS of stream services. For implementation of our system, we used OrbixWeb 3.1c following CORBA specification on Solaris 2.5/2.7, Java language, Java Media Framework API 2.0 beta2, Mini-SQL 1.0.16 and the multimedia equipments, such as SunVideoPlus/Sun Video capture board and Sun Camera. Finally, we showed a numerical data controlled by real-time negotiation and adaptation procedures based on QoS map information to GUIs on client and server dynamically, while our distributed QoS management system is executing a given streaming service.

THE EFFECT OF ABUTMENT HEIGHT ON SCREW LOOSENING IN SINGLE IMPLANT-SUPPORTED PROSTHESES AFTER DYNAMIC CYCLIC LOADING

  • Kim Nam-Gun;Kim Yung-Soo;Kim Chang-Whe;Jang Kyung-Soo;Lim Young-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.6
    • /
    • pp.664-670
    • /
    • 2004
  • Statement of problem. One of the common problems of dental implant prosthesis is the loosening of the screw that connects each component, and this problem is more common in single implant-supported prostheses with external connection. Purpose. The purpose of this study was to examine the changes of detorque values of abutment screws with external connection in different abutment heights. Materials and methods. After cyclic loading on three different abutment heights, detorque values were measured. Abutments were retained with titanium abutment screws tightened to 30 Ncm (30.5 kgmm) with digital torque gauge as recommended by the manufacturer. Replacing abutments, implants and titanium abutment screws with new ones at every measurement, initial detorque values were measured six times. In measuring de torque values after cyclic loading, Avana Cemented Abutments of 4.0 mm collar, 7.0 mm height (Osstem Co., Ltd., Seoul, Korea) were used with three different lengths of 5.0, 8.0, 11.0 mm. Shorter abutments were made by milling of 11.0 mm abutment to have the same force-exercised area of 4.5 mm diameter. Sine curve force (20N-320N, 14Hz) was applied, and detorque values were measured after cyclic loading of 2 million times by loading machine. Detorque values of initial and after-loading were measured by digital torque gauge. One-way ANOVA was employed to see if there was any influence from different abutment heights. Results. The results were as follows: 1. The initial detorque value was 27.8$\pm$0.93 kgmm, and the ratio of the initial detorque value to the tightening torque was 0.91(27.8/30.5). 2. Measured detorque values after cyclic loading were declined as the height of the abutment increased, that was, 5.0 mm; 22.3$\pm$0.82 kgmm, 8.0 mm; 21.8$\pm$0.93 kgmm, and 11.0 mm; 21.3$\pm$0.94 kgmm. 3. One-way ANOVA showed no statistically significant differences among these (p>0.05). 4. Noticeable mobility at the implant-abutment interface was not observed in any case after cyclic loading at all.

Respiratory Sinus Arrhythmia: Methods of Measurement and Interpretations of Tonic and Dynamic Vagal Cardiac Drive Index in Psychophysiology of Emotions

  • Estate M.Sokhadze;Lee, Jong-Mi;Park, Mi-Kyung;Sohn, Jin-Hun
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2000.11a
    • /
    • pp.81-87
    • /
    • 2000
  • Beat-to-beat changes in heart period (heart period variability, HPV) are mediated by fluctuations in autonomic activity. Spectral analysis is used to quantify such fluctuations in the range of 0.15-0.40 Hz (high frequency, HF), which are influenced primarily by parasympathetic factors. These fluctuations are often referred to as RSA (respiratory sinus arrhythmia), the physiological phenomenon extracted by spectral analysis and other methods including histograms of heart rate ( HR), deviations of HR etc. Respiratory sinus arrhythmia indexing with peak-to-valley method suggested by Grossman et at., (1981) yields a simple range statistic and is quantified on breath-by-breath basis, thus being quite sensitive and less dependent on recording time as compared to spectral analysis. It is strongly recommended to use at least 1 min epoch to asses HF component of HPV and at least 2 min fer low frequency (LF) of HPV and even 5 min far valid clinical assessment. Peak-to-valley statistic is limited to RSA index only, but has its pragmatic advantages. Most important is possibility of its application far relatively small epoch analysis. We used short periods (20,30, 40 sec only) and off-line analysis of RSA using ECG and respiration curve this method of assessment and proved that this method is more practically effective. The RSA index was not so far dependent on respiration pattern differences and reflected actual vagal control of HR and were accompanied by low HR under some high stress conditions and in an aversive affective visual stimulation experiments. Another factor that might modulate cardiac chronotropic response is the interaction of sympathetic and parasympathetic inputs on sino-atrial (SA) node level, because responses to vagal influences are known to be proportional to ongoing sympathetic activity, that is so called accentuated antagonism. Since sympathetic outflow (increment of influences on SA) under negative emotions or stress was high in almost all physiological responses, vagal effects on HR could be therefore potentiated, leading to masking of output cardiac response seen in HPV, In the case of moderate sympathetic activation, on the other hand, autonomic interactions in cardiac control appear to be minimal. Thus RSA index appears to be an effective alternative method to assess and measure spectral HPV.

  • PDF