• Title/Summary/Keyword: Dynamic Compaction

Search Result 125, Processing Time 0.042 seconds

Estimate of the Bearing Capacity on Subbase and Subgrade with Dynamic Plate Bearing Test (동평판재하시험을 이용한 도로하부 재료의 지지력 평가)

  • Youn, Ilro;Oh, Sewook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.8
    • /
    • pp.53-60
    • /
    • 2013
  • The compaction control method of national road substructure is using field density test to determine the relative compaction and plate bearing test to check the load bearing capacity. However, these two tests digitize a construction site manager's judgment based on his experience, so mechanical basis is weak. Resilient modulus method, which is recently being used to resolve such problem, is evaluated as a rational design method of pavement structure that can rationally reflect the stress-strain state of pavement materials that is caused by the condition of load repetition of vehicle load. However, the method of measuring the resilient modulus is difficult and lengthy, and it has many problems. To replace it, light falling weight test is recently being proposed as a simple test method. Therefore, this research uses dynamic plate loading test, which quickly and simply measures the elastic modulus of the subgrade and sub-base construction and site of maintenance, to judge the possibility of compaction control of the stratum under the road, and it proposes relation formula by analyzing the result of static load test.

A Study on Various Soil Stiffness Evaluation Methods with Field Test (현장시험을 통한 다양한 지반강성 평가방법에 대한 연구)

  • Yoo, Wan-Kyu;Kim, Byoung-Il;Kim, Ju-Hyong;Park, Keun-Bo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.4
    • /
    • pp.1373-1380
    • /
    • 2010
  • The plate loading test(PLT) and the field density test are mainly used on the construction of embankments to control the compaction of a limited layer thickness. These two test methods are very time consuming and inefficient, but they are still commonly used as the methods of quality control for soil compaction. In the last 3 decades, many devices such as geogauge, light falling weight deflectometer(LFWD) and dynamic cone penetrometer(DCP) etc., have been introduced into the engineering market with the objective of acquiring in situ stiffness properties of the compacted soil layers. Recently, a new type of sensor, called compactometer, which in mounted on the drum of a roller and measures impact forces continuously with GPS, called as Continuous Compaction Control(CCC), has come into use in many countries such as America, Germany, Japan and so on. The main objective of this paper is to assess the potential use of these new devices as quality control and assurance devices for compacted soil layers. Based on this study, compactometer and the LFWD results werestrongly correlated with the result obtained from the PLT and the field density test.

Laboratory Tests for the Applicability of Various Testing Devices for Measuring Degree of Compaction (여러가지 다짐 평가장비의 적용성을 위한 실내시험)

  • Yoo, Wan-Kyu;Lim, Nam-Gyu;Kim, Byoung-Il;Kim, Ju-Hyong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1178-1187
    • /
    • 2008
  • Quality assurance for embankment compaction is one of very important procedures to guarantee high quality construction. However, only sand replacement method (KS F2312) and static plate load test (KS F2310) which are conventional and tiresome methods are used to evaluate degree of compaction at construction fields. Recently, new types of devices such as the geogauge and the light falling weight deflectometer (LFWD), the soil impact hammer (CASPFOL) and dynamic cone penetration test etc. which are able to substitute for the conventional methods are begun to use to evaluate soil stiffness. In this study, a laboratory model test was performed to evaluate correlations among test results obtained from the new devices and to assess the potential use of them. All test results have correlations with relative density and water content. Especially, the coefficients of correlation between $E_G$ from the geogauge and $K_{30'}$ from the soil impact hammer and between $E_G$ from the geogauge and $E_{LFWD}$ from LFWD are more than 0.7 but those between the results from DCP and others are less than those between $E_{G{\cdot}}$ and $K_{30'}$ and $E_G$ and $E_{LFWD}$.

  • PDF

IDDQ Test Pattern Generation in CMOS Circuits (CMOS 조합회로의 IDDQ 테스트패턴 생성)

  • 김강철;송근호;한석붕
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.1
    • /
    • pp.235-244
    • /
    • 1999
  • This Paper proposes a new compaction algorithm for IDDQ testing in CMOS Circuits. A primary test pattern is generated by the primitive fault pattern which is able to detect GOS(gate-oxide short) and the bridging faults in an internal primitive gate. The new algorithm can reduce the number of the test vectors by decreasing the don't care(X) in the primary test pattern. The controllability of random number is used on processing of the backtrace together four ones of heuristics. The simulation results for the ISCAS-85 benchmark circuits show that the test vector reduction is more than 45% for the large circuits on the average compared to static compaction algorithms.

  • PDF

A Case Study of PHC Pile Behavior Characteristics on Dynamic Compacted High Rock Embankment (고성토 암버력 동다짐 지반에 시공된 PHC 말뚝의 거동특성 사례연구)

  • Yu, Nam-Jae;Yun, Dong-Kyun;Bae, Kyung-Tae;Kim, Hyung-Suk;Lee, Dal-Ho;Park, Yong-Man
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.519-526
    • /
    • 2010
  • The construction site for $\bigcirc\bigcirc$ transformer substation was located at a mountain valley. In order to prepare the site, the valley was first filled with crushed rock debris up to 63m. Since the main concern of this project is to minimize differential settlement of the foundation of transformer facilities, dynamic compaction was performed every 7m followed by reinforcement with EMP(Ez-Mud Piling). The EMP is one of bored piling methods, in which a hole is bored by means of air percussion and maintain by injecting Ez-Mud. Then a PHC pile (Pretensioned spun High strength Concrete pile) is embedded and finalized with a hammer. In this study, bearing capacities and long term behavior of a pile installed by EMP were investigated. To achieve these objectives, a series of tests such as static and dynamic load tests were conducted. In addition, a construction quality control standard was proposed based on the test results.

  • PDF

Soil Compaction Management Methodology using Mechanical Property (역학적 정수를 이용한 다짐관리기법에 관한 연구)

  • 강규진;최준성;김종민;노한성;김태수
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.127-132
    • /
    • 2002
  • While the pavement design is based on mechanical property such dynamic elastic modulus, the quality of highway subgrade during construction is controled by the optimum moisture content(OMC) and maximum dry density(${\gamma}$$\_$dmax/). However, since the quality control based on the OMC and maximum dry density does not consider the mechanical characteristics, there is a conceptional gap between design and PMS(pavement management system). Therefore, it is necessary to develope a new qualify control system using mechanical property for highway construction in more rational way. To achieve this goal, it is planned to perform various laboratory tests to collect mechanical properties of subgrade soil samples from several highway construction sites and to propose the relationship between dry unit weight (or OMC) and mechanical parameters. In this paper, the experimental data so far obtained are presented and analyzed. In addition, further research plan is presented and discussed.

  • PDF

Vibration Analysis of Stiffened Thick Plate Subjected to Static Inplane Stress Using Finite Element Method (면내응력을 받는 보강 후판의 유한요소법에 의한 진동해석)

  • 오숙경;김일중;이용수
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.952-956
    • /
    • 2004
  • The soil-structure interactions are caused by the point sources of explosions, deriving piles, compaction of foundations and excavations those are frequently arose in the construction sites. Thus the analysis of soil-structure interactions is one of the most important subjects in the fields of dynamic analysis and vibration control. From this viewpoint, the aim of this study is to collect the basic data for designing foundation structures throughout understanding the dynamic structural behavior, which is embodied by the dynamic analysis of soil-structure systems. In this study, the dynamic analyses of stiffened thick plates subjected to in-plane stress on elastic foundations are carried out. The foundation is modeled as Pasternak foundation that includes the continuity effect of foundations. Also both the Mindlin plate theory and Timoshenko beam-column theory are used for analyzing the thick plates and beams, respectively.

  • PDF

Applications of SASW Method to Civil Engineering (토목 공학에서의 SASW 기법의 활용)

  • Song Myung-Jun;Jung Yun-Moon;Lee Young-Nam
    • Geophysics and Geophysical Exploration
    • /
    • v.2 no.4
    • /
    • pp.174-179
    • /
    • 1999
  • Shear wave velocity, one of major elastic constants in the dynamic design for civil structures, is conventionally measured from downhole, crosshole or sonic logging tests. SASW (Spectral Analysis of Surface Waves) method, which overcomes the disadvantage of the in-hole tests, can evaluate subsurface stiffness nondestructively and nonintrusively through measuring surface waves on surface. In this paper, principles of the SASW method are briefly described and the results of various field tests, conducted to investigate the applicability of the method, are summarized. The SASW method was successfully applied in evaluating the effects of dynamic compaction at Inchon international airport site, applied in evaluating the integrity of the lining and sidewall at a testing tunnel located in Mabukri, and applied in detecting thickness of a concrete retaining wall. The results of field tests and the nondestructive and economical characteristics of the method show the promising future of the SASW method in civil engineering projects.

  • PDF

Correction Factors for Modulus Calculation Equation used in Light Weight Deflectometer Considering Track Foundation (궤도노반 강성차이를 고려한 동평판재하시험(LWDT) 동탄성계수 산정공식 수정계수)

  • Choi, Chan Yong;Lee, Jin Wook;Lim, Yuijn;Cho, Hojin
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.1
    • /
    • pp.53-62
    • /
    • 2015
  • LWDT was developed for use as an alternative technique to measure the stiffness of trackbed soils. In this study, numerical and theoretical analyses of LWDT's acting mechanism were performed. The effectiveness of the adapted elastic formula used for calculation of the dynamic modulus, Evd, was investigated theoretically and also numerically by running ABAQUS analysis. The minimum thickness of the upper layer is proposed based on the analysis. Correction factors for the formula of elastic modulus are also proposed in this study. In the future, following field test results and laboratory mechanical tests such as the resonant column test, a guideline for the use of LWDT as a standard test protocol in track construction sites, as a measuring tool for the degree of compaction and/or stiffness and dynamic modulus, will be proposed based on this analysis.