• Title/Summary/Keyword: Dynamic Analyzer

Search Result 213, Processing Time 0.028 seconds

Investigation of the SPRT-Based Android Evasive Malware

  • Ho, Jun-Won
    • International journal of advanced smart convergence
    • /
    • v.11 no.3
    • /
    • pp.23-27
    • /
    • 2022
  • In this paper, we explore a new type of Android evasive malware based on the Sequential Probability Ratio Test (SPRT) that does not perform malicious task when it discerns that dynamic analyzer is input generator. More specifically, a new type of Android evasive malware leverages the intuition that dynamic analyzer provides as many inputs within a certain amount of time as possible to Android apps to be tested, while human users generally provide necessary inputs to Android apps to be used. Under this intuition, it harnesses the SPRT to discern whether dynamic analyzer runs in Android system or not in such a way that the number of inputs per time slot exceeding a preset threshold is regarded as evidence that inputs are provided by dynamic analyzer, expediting the SPRT to decide that dynamic analyzer operates in Android system and evasive malware does not carry out malicious task.

A study on the bonding Characteristics of Inorganic/Organic Composite by Measurement of the Glass Transition Temperature(Tg) (유리전이온도(Tg) 측정에 의한 무기/유기복합체의 결합특성에 관한 연구)

  • Lee, Dong-A;Kim, Goo-Dae;Kim, Hyun-Min
    • Analytical Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.309-317
    • /
    • 1992
  • Inorganic/organic composite was synthesized by using sol-gel process, and the bonding characteristics of composite was investigated with glass transition temperature(Tg), measured by DMTA(Dynamic Mechanical Thermal Analyzer). It was found from shift of Tg to higher temperature that composite reaction was proceeded better with the amount of HCl and water. But Tg was not varied with reaction time.

  • PDF

6-Axes Articulated Robot Manipulator's Gain Tuning in consideration of dynamic specific (수직 다관절 로봇의 동적 특성을 고려한 Gain Tuning 연구)

  • Chung W.J.;Kim H.G.;Kim K.J.;Kim K.T.;Seo Y.G.;Lee K.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.744-747
    • /
    • 2005
  • This research studied 6-Axes Articulated Robot Manipulator's gain Tuning in consideration of dynamic. First of all, search fur proportional gain of velocity control loop by dynamic signal analyzer. Proportional gain of velocity control loop is connected to dynamic signal analyzer. Next Select free Proportional Gain value. And Select amplitude X of sinusoidal properly so that enough Velocity Feedback Signal may be paid as there is no group to utensil department. Next step, We can get Bode Diagram of Closed loop transfer function response examination in interested frequency. Integral calculus for gain of velocity loop is depended on integral calculus correction's number. We can obtain open loop transfer function by integrator. And we can know bode diagram's special quality from calculated open loop transfer function. With this, Velocity Control Loop's Parameter as inner loop is controlled. Next In moving, when vibration occurs, it controls notch filter. And finally, we have to control fred-forward filter parameter for elevation of control performance.

  • PDF

Building a Dynamic Analyzer for CUDA based System.

  • SALAH T. ALSHAMMARI
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.8
    • /
    • pp.77-84
    • /
    • 2023
  • The utilization of GPUs on general-purpose computers is currently on the rise due to the increase in its programmability and performance requirements. The utility of tools like NVIDIA's CUDA have been designed to allow programmers to code algorithms by using C-like language for the execution process on the graphics processing units GPU. Unfortunately, many of the performance and correctness bugs will happen on parallel programs. The CUDA tool support for the parallel programs has not yet been actualized. The use of a dynamic analyzer to find performance and correctness bugs in CUDA programs facilitates the execution of sophisticated processes, especially in modern computing requirements. Any race conditions bug it will impact of program correctness and the share memory bank conflicts to improve the overall performance. The technique instruments the programs in a way that promotes accessibility of the memory locations accessed by different threads well as to check for any bugs in the code of a program. The instrumented source code will be used initiated directly in the device emulation code of CUDA to send report for the user about all errors. The current degree of automation helps programmers solve subtle bugs in highly complex programs or programs that cannot be analyzed manually.

A study on the non-destructive characteristics of the composite structures using the Acoustic Emission (Acoustic Emission(AE)을 이용한 복합재료 구조물의 비파괴 특성 연구)

  • Lee Chang-Hun;Choi Jin-Ho;Kweon Jin-Hwe;Byun Jun-Hyung;Yu Yeun-Ho
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.139-142
    • /
    • 2004
  • As fiber reinforced composite materials are widely used in aircraft, space structures and robot arms, the study on the non-destructive testing methods of the composite materials has become an important research area for improving their reliability and safety. In this paper, the AE signal analyzer with the resonance circuit to extract the specified frequency of the acoustic emission signal were designed and fabricated. The noise levels of the fabricated AE signal analyzer by the disturbance such as impact or mechanical vibration had a very small value comparable to those of the conventional AE signal analyzer. Also, the crack detection capabilities of the fabricated AE signal analyzer under the static and dynamic tensile test were evaluated and compared with the conventional AE signal analyzer.

  • PDF

Study on the Underwater Acoustic Properties of Polyurethane Elastomer

  • Shin, Hyun Dai;Ahn, Byung Hyun
    • Elastomers and Composites
    • /
    • v.52 no.4
    • /
    • pp.326-331
    • /
    • 2017
  • Two kinds of polyurethane elastomers were prepared and their acoustical properties underwater investigated. Their dynamic mechanical properties were measured using a dynamic mechanical analyzer. The sound speed and echo reduction in the 1-50 kHz frequency range were calculated from the data obtained using the analyzer. The sound speed, transmission and attenuation cofficient in 300-800 kHz were measured in a water-filled tank. Impedance tube experiments were performed to determine the reflective coefficient and echo reduction in the 3-8 kHz range. The polyurethane elastomer containing a hollow glass sphere showed a lower reflective coefficient and a higher echo reduction than the polyurethane elastomer without a filler.

Biomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes

  • Lee, Hun;Kang, David Sung Yong;Ha, Byoung Jin;Choi, Jin Young;Kim, Eung Kweon;Seo, Kyoung Yul;Kim, Tae-im
    • Yonsei Medical Journal
    • /
    • v.59 no.9
    • /
    • pp.1115-1122
    • /
    • 2018
  • Purpose: To investigate biomechanical properties of the cornea using a dynamic Scheimpflug analyzer according to age. Materials and Methods: In this prospective, cross-sectional, observational study, participants underwent ophthalmic investigations including corneal biomechanical properties, keratometric values, intraocular pressure (IOP), and manifest refraction spherical equivalent (MRSE). We determined the relationship of biomechanical parameters and ocular/systemic variables (participant's age, MRSE, IOP, and mean keratometric values) by piecewise regression analysis, association of biomechanical parameters with variables by Spearman's correlation and stepwise multiple regression analyses, and reference intervals (RI) by the bootstrap method. Results: This study included 217 eyes of 118 participants (20-81 years of age). Piecewise regression analysis between Corvis-central corneal thickness (CCT) and participant's age revealed that the optimal cut-off value of age was 45 years. No clear breakpoints were detected between the corneal biomechanical parameters and MRSE, IOP, and mean keratometric values. Corneal velocity, deformation amplitude, radius, maximal concave power, Corvis-CCT, and Corvis-IOP exhibited correlations with IOP, regardless of age (all ages, 20-44 years, and over 44 years). With smaller deformation amplitude and corneal velocity as well as increased CorvisIOP and Corvis-CCT, IOP became significantly increased. We provided the results of determination of confidence interval from RI data using bootstrap method in three separate age groups (all ages, 20-44 years, and over 44 years). Conclusion: We demonstrated multiple corneal biomechanical parameters according to age, and reported that the corneal biomechanical parameters are influenced by IOP.