• Title/Summary/Keyword: Duty-ratio

Search Result 621, Processing Time 0.023 seconds

Sensorless Fuzzy MPPT Control for a Small-scale Wind Power Generation System with a Switched-mode Rectifier (SMR 회로를 이용한 소형풍력발전 시스템의 센서리스 퍼지 MPPT제어)

  • Lee, Joon-Min;Park, Min-Gi;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.916-923
    • /
    • 2014
  • This paper proposes a low-cost switched-mode rectifier (SMR) for a small-scale wind turbine with a permanent magnet synchronous generator (PMSG) system. Also, a sensorless Fuzzy MPPT control is realized by the proposed system. In the PMSG system with the SMR, the synchronous impedance can be replaced as the input inductor of a boost converter. Moreover, the sensorless MPPT control using the Fuzzy technique is carried out by the duty-ratio regulation of the SMR. The relation between the generating power and the duty-ratio is ruled by the chain rule. The wind turbine model is implemented by the squirrel cage induction motor and generated the variable torque when the generator speed is varied. To verify the performance of the proposed system, simulation and experimental results are executed.

Grid-tied Power Converter for Battery Energy Storage Composed of 2-stage DC-DC Converter

  • Kim, Do-Hyun;Lee, Yoon-Seok;Han, Byung-Moon;Kim, Ju-Yong;Chae, Woo-Kyu
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1400-1408
    • /
    • 2013
  • This paper proposes a new grid-tied power converter for battery energy storage, which is composed of a 2-stage DC-DC converter and a PWM inverter. The 2-stage DC-DC converter is composed of an LLC resonant converter connected in cascade with a 2-quadrant hybrid-switching chopper. The LLC resonant converter operates in constant duty ratio, while the 2-quadrant hybrid-switching chopper operates in variable duty ratio for voltage regulation. The operation of proposed system was verified through computer simulations. Based on computer simulations, a hardware prototype was built and tested to confirm the technical feasibility of proposed system. The proposed system could have relatively higher efficiency and smaller size than the existing system.

The MPPT Control Method for The Seaflow Generation by Using Fuzzy Controller (퍼지 제어기를 사용한 조류발전의 MPPT 제어법)

  • Choi, Jae-Sin;Kim, Young-Jo;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.154-156
    • /
    • 2007
  • This paper proposes new control method of maximum power point tracking for the seaflow generation system. This control system is performed by using the duty ratio control of DC/DC converter. An advantage of MPPT(Maximum Power Point Tracking)control method presented in this paper is not necessary to use the seaflow turbine characteristic at various seaflow speed and measure the tidal speed and/or the rotation speed of the seaflow generator. Therefore the resulting system ha s the characteristics of lower cost, higher efficiency and lower complexity. The fuzzy controller is used to control the duty ratio of DC/DC converter. So the reactivity and the reliablilty of the generation system is developed. Proposed control method was analyzed mathematically and tested by computer simulation by using Matlab $Simulink^{(R)}$.

  • PDF

Room temperature deposition of SiN at low radio frequency source power, $SiH_4-N_2$ plasma using pulsed-PECVD (Pulsed-PECVD를 이용한 SiN 박막의 저 소스전력 $SiH_4-N_2$ 플라즈마에서의 상온 증착)

  • Lee, Su-Jin;Kim, Byung-Whan;Uh, Hyung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.309-309
    • /
    • 2010
  • Silicon Nitride(SiN) 박막을 펄스드 플라즈마 응용화학기상법을 이용하여 저 소스전력의 $SiH_4-N_2$ 플라즈마에서 증착하였다. Duty ratio의 변화에 따른 이온에너지와 굴절률의 변화를 고찰하였다. 저이온에너지는 증착률과 강한 상관성을 보였다. 이온에너지 변수의 증착률에의 영향은 신경망 모델을 이용하여 고찰하였다.

  • PDF

Conducted Noise Reduction in Three-Phase Boost Converter using Random (3상 승압형 컨버터에 의한 전도노이즈 감소)

  • Jung, Dong-Hyo;Kim, Sang-Nam
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.79-82
    • /
    • 2003
  • The switching-mode power converter has been widely used because of its features of high efficiency and small weight and size. In the switching-mode power converter, the output voltage is generally controlled by varying the duty ratio of main switch. When a converter operates in steady state, duty ratio of the converter is kept constant. So the power of switching noise is concentrated in specific frequencies. The more white noise is injected, the more conducted EMI is reduced. But output-voltage is not sufficiently regulated. This is the reason why carrier frequency selection topology is proposed. In the case of carrier frequency selection, output-voltage of steady state and transient state is fully regulated. Spectrum analysis is performed on the Phase current and the CM noise voltage. The former is measured with Current Probe and the latter is achieved with LISN, which are connected to the spectrum analyzer respectively.

  • PDF

Experimental Study on the PWM Pressure Control Characteristics of 2 Way Solenoid Valve (2방향 전자밸브 PWM압력제어특성의 실험적 비교연구)

  • 정헌술;박성진;김창완
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.107-111
    • /
    • 1997
  • Pressure control is possible by pulse width modulation signal driving a simple ON/OFF 2-way valve of hydraulic servo system. But it indices pressure fluctuation due to repeated on-off action and the pressure varies according to the duty ratio and carrier frequency. So mean pressure and ripple amplitude are arranged by experimental study as the driving signal change which decides the pressure characteristics. As the result selection criteria of the major design parameters may be established and the basic strategy to suppress the unnecessary flucturion may be provided for a hydraulic pressure control system.

  • PDF

A Study on the Output Characteristics of theraphy $CO_2$laser AC Converter $CO_2$ Laser System using 3 Electrode-type and Ring Blower (교류콘버터 기반에서 3전극 방식의 Theraphy $CO_2$ Laser 가변출력특성의 연구)

  • 김휘영
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.257-260
    • /
    • 2002
  • In this paper, the circuit of AC Choppers for $CO_2$laser Power Supply are proposed and investigated. IGBT-controlled ac voltage regulators, operating at high frequency chopping mode. Chopping-to-supply duty ratio plays an important role in terms of laser output. Laser input energy is varied by controlling the leakage transfomer used with the proposed system. This improved circuit employs a 3 electrode-type and Ring Blower. This improved circuit system has many advantages compared with the conventional SMPS such as simple design requirment, easy implementation, high reliability, low switching loss, and consequently high efficiency. As a result, the maximun output was 16W at duty-ratio of 92%, total gas mixture of $CO_2$: $N_2$: He = 1 : 9 : 15, total pressure of 15torr.

  • PDF

The Buck DC-DC Converter with Non-Linear Instantaneous Following PWM Control Method (비선형 순시추종형 PWM 제어기법을 적용한 강압형 DC-DC 컨버터)

  • Kim Sang-Don;Ra Byung-Hun;Lee Hyun-Woo;Kim Kwang-Tae
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.470-475
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of do-dc converter. In this control method, the duty ratio of a switch is exactly equal In or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with buck converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM

  • PDF

Input-Series Multiple-Output Auxiliary Power Supply Scheme Based on Transformer-Integration for High-Input-Voltage Applications

  • Meng, Tao;Ben, Hongqi;Wei, Guo
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.439-447
    • /
    • 2012
  • In this paper, an input-series auxiliary power supply scheme is proposed, which is suitable for high input voltage and multiple-output applications. The power supply scheme is based on a two-transistor forward topology, all of the series modules have a common duty ratio, all the switches are turned on and off simultaneously, and the whole circuit has a single power transformer. It does not require an additional controller but still achieves efficient input voltage sharing (IVS) for each series module through its inherent transformer-integration strategy. The IVS process of this power supply scheme is analyzed in detail and the design considerations for the related parameters are given. Finally, a 100W multiple-output auxiliary power supply prototype is built, and the experimental results verify the feasibility of the proposed scheme and the validity of the theoretical analysis.

Characteristic Analysis of Buck Converter by using the Non-Linear Instantaneous Following PWM Controller (강압형 컨버터의 비선형 순시추종 PWM 제어기의 특성 분석)

  • Ra, Byung-Hun;Kim, Sang-Don;Kwon, Soon-Kurl;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.378-381
    • /
    • 2002
  • Instantaneous following PWM control technique is pulsed nonlinear dynamic control method. This new control technique using analog integrator is proposed to control the duty ratio D of DC-DC converter. In this control method, the duty ratio of a switch is exactly equal to or proportional to the control reference in the steady state or in a transient. Proposed control method compensates power source perturbation in one switching cycle, and the average value of the dynamic reference in one switching cycle. There is no steady state error nor dynamic error between the control reference and the average value of the switched variable. Experiments with buck converter have demonstrated the robustness of the control method and verified theoretical prediction. The control method is very general and applicable to all type PWM.

  • PDF