• Title/Summary/Keyword: Dust removal efficiencies

Search Result 15, Processing Time 0.018 seconds

A Study on the Removal of Complex Odor including Acetaldehyde and Ozone Over Manganese-based Catalysts (아세트알데히드와 오존 복합악취 저감을 위한 망간기반 촉매 성능 연구)

  • Seo, inhye;Lee, Minseok;Lee, Sooyoung;Cho, Sungsu;Uhm, Sunghyun
    • Applied Chemistry for Engineering
    • /
    • v.28 no.2
    • /
    • pp.193-197
    • /
    • 2017
  • In this study, we report on the catalyst process installed in conjunction with a wet plasma electrostatic precipitator to remove the oil mist and fine dust emitted from large-size grill restaurants. The multi-stage catalyst module reduced odor through catalytic reaction of acetaldehyde on catalysts even at an ambient temperature with ozone as an oxidant readily produced in a wet plasma electrostatic precipitator. Two types of manganese-based catalysts, $Mn_2O_3$ and $CuMnO_x$ were fabricated by extrusion molding for structured catalysts in practical applications, and the optimum conditions for high removal efficiencies of acetaldehyde and ozone were determined. When two optimized catalysts were applied in a two-stage catalyst module, the removal efficiency of acetaldehyde and ozone were ${\geq}85%$ and 100% respectively at the space velocity of $10,000h^{-1}$ and the reaction temperature of $100^{\circ}C$.

An Air Cleaning Efficiencies of Wet Air Cleaner in the Swine Finishing Winch Curtain Stall (윈치커튼식 비육돈사에서 습식공기정화기의 공기정화 효율 분석)

  • Oh, I.H.;Kim, W.G.;Lee, H.S.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.75-80
    • /
    • 2008
  • High concentration of $NH_3$, $CO_2$, and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and lamer health, and production ability. Therefore, it is necessary to keep clean the inside of stall air to increase the productivity. A wet type air cleaner has been developed to clean the stall air. The work principle is that the inside air are sucked through the fan, and the rotating discs make a water into a fineness spray and blows into the stall. The spray can take the dust, $NH_3$, and odor from the stall inside air and give back to the circulating water, which can be refreshed in 2 hours interval. In the Present study, we measured the $NH_3$, dust, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with on-mode and off-mode of wet air cleaners. In fall, the concentrations of $NH_3$ in off-mode stall were maximum 24 ppm and minimum 16 prm, and the average was 18.2 ppm. However in on-mode stall the $NH_3$ concentrations were maximum 7ppm and minimum 1ppm, and the average was 2.7ppm. The concentration of $NH_3$ in on-mode was 74% lower than off-mode stall. Odor was measured by olfactometer. In the off-mode stall, the odor unit was 3,800 OU/$m^3$, but in the on-mode stall the odor unit was 2,100 OU/$m^3$ Odor removal efficiency was about 45% in on-mode stall. The dust measure was divided into 3 categories, $PM_{10}$, $PM_{2.5}$ and $PM_{1.0}$. Whereas the $PM_{10}$ showed no significant differences between the tests, $PM_{2.5}$ and $PM_{1.0}$ in the fine particle range reduced remarkably in the on-mode.

  • PDF

Economical Ventilation Effectiveness to Reduce Hazardous Chemical Emissions for a Nail-Salon Worker

  • KWON, Woo-Taeg;JUNG, Min-Jae;LEE, Woo-Sik;KWON, Lee-Seung;SO, Young-Jin
    • Journal of Distribution Science
    • /
    • v.17 no.7
    • /
    • pp.65-76
    • /
    • 2019
  • Purpose - The purpose of this study is to investigate economical ventilation effectiveness to reduce hazardous materials exposure and damage of workers by analyzing exposure amount of noxious substances under various ventilation conditions of nail salon for indoor environments. Research design, data, and methodology - This study was carried out with cooperation of Nail shop located in SeongNam city to involve an analysis of the environmental impact indoor air quality, pollutant exposure and economical cost-effectiveness in the nail workplace. The hazardous substances were PM-10(Particulate Matter-10㎛), VOCs(Volatile Organic Compounds) and Formaldehyde, which are the major materials of nail workplace. Results - PM-10 is reduced by about 60% with air cleaner, forced artificial ventilation by 32%, and natural ventilation by about 12%. TVOCs and Formaldehyde showed similar efficiency (80~100%) after natural ventilation and ventilation after 60 minutes. The removal efficiencies of VOCs and formaldehyde were similar to those of natural ventilation and mechanical ventilation system. However, in case of dust, natural ventilation was reduced by artificial ventilation system due to inflow of external dust during natural ventilation. Conclusions - If the pollution degree of outdoor air is not high, air volume is high, and natural ventilation is performed when the air conditioning and heating system is not operated. Even at the end of the work, it keeps operating for 60 minutes to remove the pollutants generated. Results of this analysis demonstrated that the worker environment can be improved by adopting institutional legislation and guidelines for ventilation.

Investigation of Water-Washing Process Parameters for Removal of Alkali Metals and Chlorides from Electric Arc Furnace Dust (EAFD) (전기 제강로 분진(EAFD)으로부터 알칼리 금속 및 염화물 제거를 위한 수 세척 공정 운영인자 조사)

  • Lee, Han Saem;Park, Da so mi;Ha, Jong Gil;Shin, Hyun Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.11
    • /
    • pp.626-633
    • /
    • 2017
  • The present study investigated the effect of a water-washing process, which is part of the acid hydrometallurgical process for recovery of high purity of zinc, on the removal of alkali metals and chlorides (Na, K, Ca, Cl) from Electric arc furnace dust (EAFD). Two EAFD samples with different properties were characterized by particle size, XRD and element analysis, and their washing efficiencies (%) on alkali metals and chlorides were compared according to pH, washing time, liquid to solid (L/S) ratio and number of washings. The results show that the alkali metals and chlorides could be effectively removed by the washing (at L/S ration of 3 for more than 30 min., pH 10~11) while minimizing loss of zinc (<0.1%), in which the washing efficiency was Na-78%, K-76%, Cl >99%, respectively. Na and K could be removed up to 97% and 89% respectively by 3 times of repeated washings. With increased sample volume (10 times) of the mixed (1:1, w/w) sample with two types of EAFD, it was confirmed that the pH(10~11) can be used as the main process control parameter for the washing of the alkali metals regardless of EAFD properties.

A Study on the Characteristics of Oil-water Separation in Non-point Source Control Facility by Coalescence Mechanism of Spiral Buoyant Media (나선형 부유 고분자 여재의 Coalescence 특성을 이용한 비점오염원 저감시설의 유수분리특성 연구)

  • Kang, Sung-Won;Kim, Seog-Ku;Kim, Young-Im;Yun, Sang-Leen;Kim, Soo-Hae;Kim, Mee-Kyung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.8
    • /
    • pp.950-955
    • /
    • 2007
  • Non-point source control system which had been designed only for oil-water separation in the fields of oil refinery and garage was upgraded in this research for the removal of runoff pollutants in impervious urban area. Pollutants including oil from driveway and bridge were eliminated by two types of pathway in the system. One is the coalescence mechanism that the oil droplets in the runoff come into contact with each other in the spiral buoyant media surface and form larger coalesced droplets of oil that are carried upstream to the oil layer. The other is the precipitation that solids in runoff were settled by gravity in the system. In this research, coalescing characteristics of oil and water separation were investigated through image analyses, and efficiencies of the non-point source control system were evaluated using dust in driveway and waste engine oil. Media made of high density and high molecular weight polyethylene was indeterminate helical shape and had sleek surface by analysing SEM photographs and BET. Surface area and specific gravity of media which were measured directly were 1,428 $mm^2$ and 45.3 $kg/m^3$ respectively. From the image analyses of the oil droplets photographs which were taken by using microscope, it was proved clearly that the coalescence was the main pathway in the removal of oil from the runoff. Finally, the performances of the non-point source control system filled up with the media were suspended solid $86.6\sim95.2%$, $COD_{Cr}$, $87.3\sim95.4%$, n-Hexane extractable materials $71.8\sim94.8%$ respectively.