• 제목/요약/키워드: Dust Removal

검색결과 194건 처리시간 0.021초

Expression of Bitter Taste Receptors in Human Nasal Respiratory Epithelium

  • An, Jeong-Mi;Wu, Hee-Won;Kim, Hyun-Jun;Kim, Chang-Hoon;Moon, Seok-Jun
    • International Journal of Oral Biology
    • /
    • 제37권2호
    • /
    • pp.57-62
    • /
    • 2012
  • The nasal cavity encounters various irritants during inhalation such as dust and pathogens. To detect and remove these irritants, it has been postulated that the nasal mucosa epithelium has a specialized sensing system. The oral cavity, on the other hand, is known to have bitter taste receptors (T2Rs) that can detect harmful substances to prevent ingestion. Recently, solitary chemosensory cells expressing T2R subtypes have been found in the respiratory epithelium of rodents. In addition, T2Rs have been identified in the human airway epithelia. However, it is not clear which T2Rs are expressed in the human nasal mucosa epithelium and whether they mediate the removal of foreign materials through increased cilia movement. In our current study, we show that human T2R receptors indeed function also in the nasal mucosa epithelium. Our RT-PCR data indicate that the T2R subtypes (T2R3, T2R4, T2R5, T2R10, T2R13, T2R14, T2R39, T2R43, T2R44, T2R 45, T2R46, T2R47, T2R48, T2R49, and T2R50) are expressed in human nasal mucosa. Furthermore, we have found that T2R receptor activators such as bitter chemicals augments the ciliary beating frequency. Our results thus demonstrate that T2Rs are likely to function in the cleanup of inhaled dust and pathogens by increasing ciliary movement. This would suggest that T2Rs are feasible molecular targets for the development of novel treatment strategies for nasal infection and inflammation.

젖소분뇨로부터 최대 바이오가스 생산과 유기물 제거효율을 달성하기 위한 반건식 간헐주입 연속혼합 혐기성반응조의 최적 수리학적 체류시간 도출을 위한 연구 (Assessment of Optimum Hydraulic Retention Time (HRT) for Maximum Biogas Production and Total Volatile Solid (TVS) Removal Efficiency of Semi-Continuously Fed and Mixed Reactor (SCFMR) Fed with Dairy Cow Manure)

  • 강호;김선우;정지현;안희권;정광화
    • 대한환경공학회지
    • /
    • 제37권12호
    • /
    • pp.696-704
    • /
    • 2015
  • 본 논문은 톱밥 깔개 젖소분뇨 TS 13%를 반건식 간헐주입 연속혼합 반응조(Semi-Continuously Fed and Mixed Reactor, SCFMR)에 주입하여 신재생에너지인 바이오가스의 생산성과 TVS 제거효율을 비교 평가하여 최적 운전조건을 도출하고자 하였으며, 그 연구결과를 요약하면 다음과 같다. 톱밥 깔개 젖소분뇨 주입 TS 13%의 반건식 SCFMR의 운전결과 HRT 25일(OLR $4.40{\sim}4.50kg\;VS/m^3-day$)에서 최대 바이오가스 발생량 1.44 v/v-d와 $CH_4$ 발생량 1.12 v/v-d를 달성하였으며, 이 때 TVS 제거효율은 바이오가스 발생량 기준 37%이었다. 이는 톱밥 깔개 젖소분뇨 1일 100 kg 주입 시 $3.60m^3$의 바이오가스를 생산하는 결과이다. 높은 유기물 부하율인 OLR $4.45kg\;VS/m^3-day$(HRT 25일)에서 SCFMR의 운전이 안정적인 이유는 주입시료인 톱밥 깔개 젖소분뇨가 갖고 있는 높은 Alkalinity 농도 때문이다. 그 결과 반응조의 Alkalinity는 14,500~15,600 mg/L as $CaCO_3$ 범위이었으며, 반응조의 안정성을 평가하는 V/A 비는 평균 0.11, P/A 비는 평균 0.43을 유지하였다.

전기 제강로 분진(EAFD)으로부터 알칼리 금속 및 염화물 제거를 위한 수 세척 공정 운영인자 조사 (Investigation of Water-Washing Process Parameters for Removal of Alkali Metals and Chlorides from Electric Arc Furnace Dust (EAFD))

  • 이한샘;박다소미;하종길;신현상
    • 대한환경공학회지
    • /
    • 제39권11호
    • /
    • pp.626-633
    • /
    • 2017
  • 본 연구에서는 전기 제강로 분진(EAFD)으로부터 고 순도의 아연회수를 위한 산 습식법 중 알칼리 금속 및 염화물(Na, K, Cl) 제거를 위한 적정 수 세척공정의 운영조건에 대해 조사하였다. 서로 다른 성상을 가지는 두 종류의 EAFD 시료를 대상으로 원소분석, XRD, 입도 분석 등의 물리화학적 특성을 분석하였고, 세척액의 pH, 세척시간, 고액비(mL/g) 및 세척반복횟수 등에 따른 알칼리 금속 및 염화물의 세척효율(%)을 비교하였다. 연구 결과, EAFD 내 알칼리 금속과 염화물은 고액비 3, 세척시간>30, pH 10~11의 조건에서 아연과 철의 손실을 최소화하면서(<~0.1%) 효과적으로 제거할 수 있었으며, 1회 세척시 Na-78%, K-76%, Cl >99%의 세척효율을 보였다. Na와 K는 3회 반복 세척 시 각각 97%, 89%까지 제거 가능하였다. 두 종류의 EAFD 혼합(1:1)시료를 대상으로 시료 용량을 늘려(10배) 수행한 실험 결과에서도 세척액의 최종 pH 10~11에서 Zn의 손실 없이 Na, K, Cl 등을 효과적으로 제거 가능함을 확인하였다.

바이오 필터를 이용한 비육돈사 배기덕트 시설의 악취저감 효과 (Odor Removal Efficiency of Biofilter Ducting Systems in Indoor Pig House)

  • 송준익;최홍림;최희철;권두중;유용희;전중환
    • 한국축산시설환경학회지
    • /
    • 제13권3호
    • /
    • pp.195-200
    • /
    • 2007
  • 무창 육성 비육돈사에 대한 악취 제어 효율 비교분석을 위하여 Biofilter 덕트에 의한 악취 제어 연구를 수행하였다. 본 실험은 서울대 부속목장 실험돈사에서 실시하였으며 실험결과는 다음과 같다. 1. 무창 육성비육돈사에서 여름철 최대 배기시 바이오필터 외부로 배출되는 공기속도는 볏짚(.0.77 m/s), ALC(0.56 m/s)으로 측정되었다. 2. 실험시작 5일 후 가스검지기(GV-100)에 의한 간이측정시 암모니아($NH_3$) 농도는 필터 통과 후 볏짚($2mg/{\ell}$), ALC(3ppm)로 측정되어 부자재 사이의 공극율이 높은 볏짚이 높게 나타났다. 부자재에 따른 필터외부에서의 먼지측정 결과 볏짚($93\;mg/m^3$), ALC($32\;mg/m^3$)으로 측정되어 볏짚은 볏짚 간의 넓은 공극에서 발생하는 먼지 및 돈사내부의 먼지가 혼합되어 필터 외부로 배출되어 돈사내부보다 높게 측정되었다. 3. 황화수소($H_{2}S$) 가스농도 변화는 돈사내부에서는 측정일 7일(6 ppm), 21일(5 ppm) 및 36일(7 ppm) 경과함에 따라 어느 일정 시점에서 황화수소 가스농도는 증가하지 않았으나 다른 필터여재에서는 일정한 경향은 보이지 않았다. 이상의 실험결과를 종합해 볼 때 무창 육성비육 돈사에서 Biofilter를 이용한 악취저감 효과를 확인할 수 있었다.

  • PDF

싸이클론과 배플 및 백필터 원리를 결합한 하이브리드형 집진기의 최적화 설계를 위한 수치해석 (A Numerical Study on an Optimum Design of a Hybrid Collector Coupled with the Principle of Cyclone, Baffle and Bag-Filter)

  • 홍성길;정유진;임기혁;유정근;손병현
    • 한국산학기술학회논문지
    • /
    • 제14권2호
    • /
    • pp.983-989
    • /
    • 2013
  • 본 연구에서는 하나의 장치 내에서 "싸이클론-관성충돌-여과포 집진"이 동시에 이루어지는 멀티 집진기의 집진 효율을 극대화시키기 위한 설계 조건을 검토하였다. 먼저 싸이클론의 입구 형상에 대한 수치 해석 결과, 접선 유입식 입구에 가이드 베인을 추가로 설계한 경우 선회류의 회전수가 많고 강하게 형성되어 사이클론부에서 조대입자의 유선 이탈을 촉진시키는데 매우 효과적인 것으로 예측되었다. 그러나 사이클론의 하단부가 벤츄리 모양이기 때문에 약 4~5 m/s의 강한 하향 흐름이 호퍼 하단까지 지속되어 분진의 재비산 가능성이 있는 것으로 나타났다. 이에, 사이클론부 하단의 벤츄리를 제거하며 분진 재비산 문제는 해소 가능할 것으로 나타났다. 충돌 차단형 배플의 간격을 조정하여 통과유속을 빠르게 한 결과, 충돌 효과는 더욱 증가할 것으로 예측되었으나 탈리 분진이 간섭을 받을 수 있는 문제점이 예상되어 배플은 기본 설계안대로 유지하는 것이 바람직할 것으로 나타났다.

돈사 작업장 유형에 따른 입자상 오염물질의 실내농도 및 발생량에 관한 현장 조사 (Field Study of Concentrations and Emissions of Particulate Contaminants by Types of Swine Houses in Korea)

  • 김기연;박재범;김치년;이경종
    • Journal of Preventive Medicine and Public Health
    • /
    • 제38권2호
    • /
    • pp.141-146
    • /
    • 2005
  • Objectives: Particulate contaminants, such as total and respirable dusts, can harm the health of farm workers via several routes. The principal aims of this field study were to determine the concentrations and emissions of particulate contaminants: total and respirable dusts, in the different types of swine houses used in Korea, and allow objective comparison between Korea and the other countries in terms of swine housing types. Methods: The swine houses investigated in this research were selected with respect to three criteria: the manure removal system, ventilation mode and growth stage of pigs. Measurements of total and respirable dust concentrations and emissions in the swine houses were carried out on 5 housing types at 15 different farm sites per housing type. The swine houses investigated were randomly selected from farms situated within the central districts in Korea: province of Kyung-gi, Chung-buk and Chung-nam. Results: The total and respirable dust concentrations in the swine houses averaged $1.88\;and\;0.64mg/m^3$, ranging from $0.53\;to\;4.37mg/m^3$ and from $0.18\;to\;1.68mg/m^3$, respectively. The highest concentrations of total and respirable dusts were found in the swine houses with deep-litter bed systems: $2.94mg/m^3\;and\;1.14 mg/m^3$, while the lowest concentrations were found in the naturally ventilated buildings with slats: $0.83mg/m^3\;and\;0.24mg/m^3$, respectively (p<0.05). All the swine houses investigated did not exceed the threshold limit values (TLVs) for total ($10mg/m^3$) and respirable ($2.5mg/m^3$) dusts. The mean emissions of total and respirable dusts, per pig (75 kg in terms of live weight) and area ($m^2$), from the swine houses were 97.33 and 9.55 mg/h/pig and $37.14\;and\;12.83mg/h/m^2$, respectively. The swine houses with deep-litter bed systems showed the highest emissions of total and respirable dusts (p<0.05). However, the emissions of total and respirable dusts from the other swine houses were not significantly different (p>0.05). Conclusion: The concentrations and emissions of total and respirable dusts were relatively higher in the swine houses managed with deep-litter bed systems and ventilated naturally of the different swine housing types tested. In further research, more farms than the number used in this research should be investigated, which will present objective and accurate data on the concentrations and emissions of total and respirable dusts in Korean swine houses. In addition, personal sampling should be performed to objectively assess the exposure level of farm workers to particulate contaminants.

그래프 기반 영역 분할 방법을 이용한 매체 전달량 계산과 가시성 복원 (Estimation of the Medium Transmission Using Graph-based Image Segmentation and Visibility Restoration)

  • 김상균;박종현;박순영
    • 전자공학회논문지
    • /
    • 제50권4호
    • /
    • pp.163-170
    • /
    • 2013
  • 일반적으로 외부에서 획득되는 영상은 대기 중에 존재하는 먼지, 물방울, 연무, 안개, 연기 등에 의해 화질이 감쇠되고 결과적으로 대비도 감소와 색상의 왜곡 현상이 발생한다. 그리나 안개와 배경 사이에 내재된 모호성 때문에 배경으로부터 안개를 제거하는 작업은 결코 간단한 문제가 아니다. 본 논문에서는 단일 영상에서 비용함수로서 에지의 기울기를 이용한 그래프 기반 영역 분할 방법을 이용하여 안개 제거를 위한 새로운 방법을 제안한다. 우리는 장면을 깊이 관련 정보에 따라 여러 영역으로 분리하고 전역적인 안개값을 추정한다. 매체의 전달량은 그래프 기반 영역 분할 알고리즘의 임계 함수에 의해서 직접적으로 계산된다. 매체 전달량과 안개값이 계산되면 안개 모델식에 의해서 쉽게 안개가 제거된 영상을 복원할 수 있다. 그리고 안개 영상과 복원된 영상간의 에지의 기울기 비율을 계산함으로써 기존의 연구 방법과 제안된 연구 방법의 가시성 복원 정도를 비교 평가하였다. 다양한 안개 영상에 대한 실험 결과 제안된 방법의 우수한 안개 제거 및 화질 복원 능력이 입증되었다.

MODELING OF THE ZODIACAL LIGHT FOR THE AKARI MID-IR ALL-SKY DIFFUSE MAPS

  • Kondo, Toru;Ishihara, Daisuke;Kaneda, Hidehiro;Oyabu, Shinki;Amatsutsu, Tomoya;Nakamichi, Keichiro;Sano, Hidetoshi;Ootsubo, Takafumi;Onaka, Takashi
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.59-61
    • /
    • 2017
  • The AKARI 9 and 18 µm diffuse maps reveal the all-sky distribution of the interstellar medium with relatively high spatial resolution of ~6". The zodiacal light is a dominant foreground component in the mid-infrared. Thus, removal of the zodiacal light is a critical issue to study low surface brightness Galactic diffuse emission. We carried out modeling of the zodiacal light based on the Kelsall model which is constructed from the COBE data. In the previous study, only a time-varying component of the zodiacal light brightness was used for determination of the model parameters. However, there remains a residual component of the zodiacal light around the ecliptic plane even after removal with the model. Therefore, instead of using a time-varying component, we use the absolute brightness of the zodiacal light and we find that the new model can better remove the residual component. As a result, the best-fit model parameters are changed from those in the previous study. We discuss the properties of the zodiacal light based on our new result.

500 MW 석탄화력발전소 촉매단추가에 따른 탈질설비 효율에 미치는 영향 (Effect of addition of a catalystic layer on Denitrification System efficiency in a 500 MW Coal-fired Power Plant)

  • 이상수;문승재
    • 플랜트 저널
    • /
    • 제17권1호
    • /
    • pp.58-66
    • /
    • 2021
  • 최근 미세먼지 등 대기오염물질 배출에 대한 전국민적 우려로 정부는 대기오염물질 배출규제 강화정책을 내놓고 있다. 국내 석탄화력발전소는 대기환경설비 성능개선에 박차를 가하고 있으며, 이 논문에는 500 MW급 표준석탄화력 탈질설비에 촉매단을 추가하는 성능개선사례를 다루고 있으며, 촉매단 추가 전·후 성능시험시험과 NOx제거효율에 따른 탈질설비 핵심성능 인자의 변화를 살펴보았다. 연구결과 촉매단 추가 전·후 탈질설비 효율은 80%에서 88%로 상승했고, 핵심성능인자인 미반응 암모니아, SO2/SO3 전환율은 설계보증치를 만족하였으나, 차압의 경우 설계보증치를 초과하였다. 동시에, NOx 제거효율에 따른 핵심성능인자 변화는, 미반응 암모니아 농도, 차압 항목은 NOx 제거효율이 증가에 따라 같이 증가하는 양상을 보여 관리 및 개선이 필요하다는 결과를 얻을 수 있었다.

산업 현장에 적용할 수 있는 휴대형 정전기 측정기 설계 및 구현 (Design and Implementation of Portable Electrostatic Meter Applicable to Industrial Site)

  • 장문석;이응혁
    • 한국산업융합학회 논문집
    • /
    • 제23권6_2호
    • /
    • pp.971-977
    • /
    • 2020
  • In this paper, We propose a portable electrostatic meter which can measure high voltage static electricity caused by friction to prevent fire or explosion accidents in grinding, crushing, power injection, transport, filling, dust removal, painting, and foreign matter removal processes. The proposed device not only shows static electricity strength in 4 steps with respect to distance and voltage but also gives warning with a buzzer, on process facilities that are likely to generate high voltage static electricity due to friction. The device is implemented by filtering the signal detected by the wireless antenna, amplifying the signal by 6 times, and passing the signal through the integrator circuit. Tests are carried out with an electrostatic discharge simulator. And the results show that 4 LEDs are turned on at the distance of 10cm, 3 LEDs at 12cm, 2 LEDs at 13cm, and 1 LED at 15cm, when a fixed voltage of 500V is given. And also, the tests show that the static electricity can be detected at 5cm on 100V, 10cm on 200V, 15cm on 500V, 20cm on 1000V, and 25cm on 1500V. We expect to reduce accidents caused by static electricity by allowing safety managers on fields where fire or explosion accidents can happen to monitor static electricity.