• 제목/요약/키워드: Dust Collector

검색결과 102건 처리시간 0.029초

가시화기법을 이용한 다단형 하이드로 사이클론 어란 (魚卵) 집진장치의 개선에 관한 연구 (An advanced study of multi-stage type hydrocyclone dust collector for fish egg collecting using Visualization)

  • 최은희;편용범;이승헌;이경훈
    • 수산해양기술연구
    • /
    • 제53권4호
    • /
    • pp.404-412
    • /
    • 2017
  • A centrifugal cyclone dust collecting apparatus includes a hydro cyclone dust collecting apparatus for separating solid or liquid using liquid or suspension as a medium. In this study, the formation mechanism and improvement of air core and inner air layer were confirmed through Particle Image Velocimetry. These results showed that the modified experimental model was designed in the conventional method suitable for the separation of juvenile fish and eggs. The inlet speed of the multi-stage hydrocyclone dust collector, which can increase the inlet velocity and minimize floatage in the turbulence chamber, was increased from 0.15 to 0.30 m/s. As a result, the air core was stably formed, the inner air layer was increased with increasing speed. In addition, the dust collecting efficiency of egg and juvenile fish was 97.8% on average, It can infer that this system confirmed the ability to efficiently collect particles of $40{\mu}m$ or more.

역률보상형 전기집진기 전원장치 특성연구 (A study on power source characteristic of a dust collector for power factor compensating)

  • 이동길;홍지태;김호성;손민규;이경준;김종락;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1326-1327
    • /
    • 2008
  • Recently, the air pollution is supposed is to be the most serious environmental problem. Therefore, a small air cleaner is asked to make comfortable indoor environment for the moderns who have frequent indoor activity. In this study, without generating of the second pollution source, dust in the air and harmful microorganisms can be removed by the electric dust collecting technology which has high reliability and efficiency to be able to remove the impurities even though it is just 0.01${\mu}m$. Accordingly, power sources of the dust collector use, it is not inefficiency and offering to dust collector unstable. In order to overcome the point at issue, a this study, for power factor compensating use the PFC circuit, for removing the noise use EMI filter and for generating the hight voltage use the Cockcroft Walton Circuit. And we study power source on characteristic and improvement.

  • PDF

집진기의 공기소모량과 백 필터내의 압력전파에 대한 실험적 연구 (Experimental Investigation on Air Consumption and Pressure Wave Propagation inside A Filter Bag of A Dust Collector)

  • 정원락;홍성철
    • 한국산학기술학회논문지
    • /
    • 제9권4호
    • /
    • pp.886-891
    • /
    • 2008
  • 이 연구는 필터 백을 사용하는 집진기에서 펄스밸브에 부착된 솔레노이드 밸브의 통전 시간과 공기소모량 사이의 관계를 실험적으로 규명하였으며 이 때 필터 백에 작용하는 압력파의 전달과정을 고찰하였다. 펄스당 공기소 모량이 집진기 운전비용의 주요 요소이므로 펄스제트의 전파과정을 관찰하고 압력파형과 공기소모량을 측정하였다. 또 주어진 조건하에서 필터 백의 길이의 영향을 고찰하고 효율적인 탈진작용을 할 수 있는 통전시간과 충격량 사이의 관계를 규명하였다 주어진 실험조건 범위에서는 통전시간이 짧을수록 더 큰 충격량을 얻을 수 있으며 동일한 통전 시간에 대하여는 여러 번의 짧은 펄스를 발생시키는 것이 더 효율적인 것으로 나타났다.

사이클론-카트리지필터 일체형 가우징 집진기의 유동해석 (Flow Analysis of Cyclone-Cartridge Filter Gausing Collector)

  • 장성철;정대영;조정식
    • 한국산업융합학회 논문집
    • /
    • 제21권3호
    • /
    • pp.133-139
    • /
    • 2018
  • Precipitator is the most widespread device used to separate dust particles from the exhaust gas. In the shipyard, welding umbrellas, spark protection covers, and ventilators are not purchased and used for the work place to capture the flames and high temperature metal dust generated during the gardening process. In particular, a thorough analysis of design factors, such as capture rate, collection capacity calculation, filter speed, and materials selection, is required since spatial constraints are followed by structures, etc. In this study, conceived to address problems such as this cyclone and filtration filter system that combines all-in-one gausing collector prototype. Assessed through interpretation through the validity of the design and reliability.

알루미늄 주조과정에서 배출되는 입자상물질의 물리·화학적 특성 (Physicochemical Characteristics of Particulate Matter Emitted from Aluminum Casting Process)

  • 서정민;박정호
    • 한국환경과학회지
    • /
    • 제33권5호
    • /
    • pp.297-304
    • /
    • 2024
  • PM (Particulate Matters) was collected from a bag filter dust collector at an aluminum foundries, and its physicochemical properties were investigated using particle size analyzer and scanning electron microscopy with energy dispersive X-ray spectrometer (SEM/EDS). The median volume diameter of the particles passing through the pretreatment dust collector of the cyclone was approximately 10 ㎛. The cyclone pretreatment dust collector was shown to significantly reduce the throughput of large particles with a particle size of 100 ㎛ or more. The chemical composition of the particles showed a high Al content, and trace amounts of Mg, Si, and Zn were detected.

흙먼지 분리기 용이한 원형베일 세절 조사료의 사이클론 이송장치 개발 (Development of Cyclone Conveying System for Transporting Chopped Round Bale Roughage and Separating Dust)

  • 하유신;권진경;박경규
    • Journal of Biosystems Engineering
    • /
    • 제36권3호
    • /
    • pp.204-210
    • /
    • 2011
  • This study developed the cyclone conveying system using roughage cutter for the round bale reported in the previous papers. Performance tests were conducted whether it can easily separate dust from roughage such as rice straws and it can transport roughages from cutter to TMR mixer. In addition, the airflow patterns in the cyclone conveying system were investigated using CFD code (FLUENT 6.2) for various velocities of dust collection fan. The cyclone conveying system was designed based on dried rice straws with a diameter of 1,340 mm, a cylinder length of 1,220 mm, a cone length of 850 mm and the current velocity of the dust collection fan was 15~20 m/s. It was found that transporting of roughage from cutter to TMR mixer and the separation of dust were satisfactory, and the dust removal rate of rice straws was around 31.9%. CFD analysis showed that, at the blowing fan velocity of 11.6 m/s, the airflow velocity inside the dust collector increased as velocity of the dust collection fan increased, but the airflow patterns inside the dust collector were all much the same.

싸이클론 집진기의 수치해석적 연구 (Numerical Study of Cyclone Dust Collector)

  • 전영남;엄태인
    • 한국대기환경학회지
    • /
    • 제12권1호
    • /
    • pp.43-53
    • /
    • 1996
  • Numerical simulation was performed for the 3-dimensional flow filed of gas and particle phase for cyclone dust collector. FVM(Finite Volume Method) was employed for gas phase. The flow was solved suing the k-.varepsilon. epsilon turbulence model. The particle exit at the bottom of the cone was treated as a solid wall in this model because the gas flow through the effective dust exit is usually insignificant. The major parameters considered in this study was vortex finder diameter, effective dust exit diameterm vortex finder length, inlet type for dimension performance. Particle trajectory calculations were made for three different, particle sizes of 1, 25 and 50 .mu.m. The results obtained from this study give some physical insight of dust particle collection mechanism together with the indication of the collection efficiency. The simulation results were in generally good agreement with empirical knowledge. The application of this kind of computer program looks promising as a potential tool for the design of cyclone and determination of optimum operating condition.

  • PDF

치과기공사의 분진노출 수준 및 개인보호구 착용 실태 - 대구지역을 중심으로 - (Assessment of dust exposure and personal protective equipment among dental technicians)

  • 박수철;전만중;사공준
    • 대한치과기공학회지
    • /
    • 제33권1호
    • /
    • pp.93-102
    • /
    • 2011
  • Purpose: The study aimed to evaluate working environment for dental technician by measuring dust level, ventilation conditions and the use of personal protective equipment and to provide basic information required to improve working environment and develop health education programs for dental technician. Methods: A total of 240 dental technician who are registered with the Daegu Association of Dental technician and working at 34 dental laboratories participated in the study. And the dust level was measured at 21 different spots in 16 dental laboratories out of 34. Results: Of 34 dental laboratories, 31 (91.2%) were equipped with a ventilator, but the remaining 3 (8.8%) did not have a ventilator. By the number of ventilator, 1 to 3 ventilators were found in 22 dental laboratories (71.0%), 4 to 6 ventilators were in 7 laboratories (22.5%) and more than 7 ventilators in 2 laboratories(6.5%). According to the frequence of changing filters in dust collector, 20 dental laboratories (58.9%) changed filters every four weeks, 10 laboratories (29.4%) changed them every six weeks and 4 laboratories (11.7%) changed them every eight weeks. Of total respondents, 114 (61.3%) said they wore a mask all the time while working, 56 (29.6%) said they frequently wore a mask, 19 (10.1%) said they did not wear a mask. As for the type of masks, 159 (84.1%) used a disposable mask, 25 (13.2%) used a cotton mask and 5 (2.7%) used an anti-dust mask. For dust sat on their outfits while working, 102 (54.0%) shook their uniforms inside workplace to keep dust off the uniforms, 64 (33.9%) did not anything until they wash their uniforms and 23 (12.1%) shook their uniforms outside workplace to keep dust off the uniforms. Of total respondents, 182 (96.3%) had a particle in their eyes while carrying out grinding work. Based on the measurement of floating dust at workplace, 3 dental laboratories showed dust concentration exceeding the minimum level of 10 mg/$m^3$ allowed under the permit for environment. Of those, 1 laboratory had the dust concentration that was more than 1.5 times higher than the minimum level. Dust concentration was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Dust comprised of nickel (more than 70%), chrome (9%) and others. The mean chrome concentration was more than twice higher than the minimum permissible level of 0.5 mg/$m^3$. There were two laboratories that showed chrome concentration exceeding the level of 0.4 mg/$m^3$. Like dust concentration, chrome level was higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. There were six laboratories that had nickel concentration exceeding the minimum permissible level of 1 mg/$m^3$. Of those, one laboratory had nickel concentration that was more than three times higher than the minimum permissible level. Nickel concentration was also higher in laboratories that used a dust collector with 0.5 horse power and changed filters more than 3 weeks ago. Conclusion: It is not likely that heavy metal concentrations found in the study constitute respiratory dust. It is however necessary for health of dental technician to apply the Industrial Safety and Healthy Law to dental laboratories and make recommendations for the use of personal protective equipment, installation of a proper number of ventilators, more frequent change of filters in dust collector and improved ventilation for polishing work. At the same time, dental technician need education on how to use personal protective equipment and how to efficiently remove dust from their uniforms.

변형된 사이클론 먼지포집기의 이용이 무창계사의 먼지농도에 미치는 영향 (Effect of Modified Cyclone Dust Collector in Windowless Broiler Building)

  • 최희철;연규영;송준익;강희설;권두중;유용희;양창범;천상석;김용국
    • 한국축산시설환경학회지
    • /
    • 제13권2호
    • /
    • pp.97-104
    • /
    • 2007
  • 본 연구는 변형된 사이클론식 먼지포집기를 이용하여 계사의 먼지농도를 낮추고자 먼지포집기를 개발하였으며 무창육계사에서의 먼지 저감효과를 알아보고자 경기 화성 소재 육계농장의 무창계사에서 시험을 수행하였으며 그 결과는 다음과 같다. 1. 시험계사의 환기량은 2주령시 $0.014{\sim}0.015cmm$ 이었으며 5주령시에는 $0.158{\sim}0.181cmm$이었다. 암모니아가슬 농도는 1주령시 $13{\sim}16\;ppm$, 2주령시 $20{\sim}24ppm$이었으며 $CO_2$ 농도는 1주령시 400-500ppm이었으며 2주령 시 $1,000{\sim}2,000ppm$이었다. 2. 먼지포집기의 기계별 1주간 먼지포집량은 1주령시 104.1g, 2주령시 274.7g, 3주령시 388.6g으로 증가하다가 4주령에는 감소하였다. 3. 먼지포집기의 주령별 먼지 포집효율은 TSP의 경우 먼지포집기를 통과하기전 $3,111.7{\sim}8,745.2\;{\mu}g/m^3$로 높았으나 먼지포집기를 통과하고 난 후 $530.8{\sim}2,264.4\;{\mu}g/m^3$로 낮아져 $54.2{\sim}82.9%$의 효율을 보였으나 PM1.0의 경우 통과전 $15.2{\sim}39.0\;{\mu}g/m^3$에서 통과 후 $11.9{\sim}34.9\;{\mu}g/m^3$$7.6{\sim}33.8%$의 낮은 포집효율을 보였다. 4. 대조구의 경우 1주령시 TSP 농도는 $1,387.6\;{\mu}g/m^3$, 4주령시 $4,210.1\;{\mu}g/m^3$으로 높았으나 먼지포집기가 설치된 시험구의 경우 1주령시 $876.3\;{\mu}g/m^3$, 4주령시 $2,535.3\;{\mu}g/m^3$으로 $36.8{\sim}39.8%$의 먼지 저감효과가 있었다. 그러나 PM2.5, PM1.0의 경우 $11.4{\sim}39.8%$의 낮은 먼지저감 효과가 있었다. 5. 대조구의 경우 폐사율은 4.06%이었으나 시험구는 3.13%으로 낮아졌으며 출하체중도 대조구는 1.658kg인데 비하여 시험구는 1.742kg으로 높았다.

  • PDF