• Title/Summary/Keyword: Ductile-to-brittle transition temperature

Search Result 82, Processing Time 0.029 seconds

A Study on the Fracture Stress in Miniaturized Charpy Impact Specimens (소형 샤르피 충격시험편에서의 파괴응력에 관한 연구)

  • Nahm, Seung-Hoon;Kim, Am-Kee;Lee, Dae-Yeol;Kim, Si-Cheon
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.132-137
    • /
    • 2001
  • Miniaturized specimen technology is useful to characterize the mechanical behavior using a minimum volume of material, because it is almost impossible to sample the conventional specimen for the fracture toughness test without damage to equipment. Test material was 1Cr-1Mo-0.25V steel which was widely used for turbine rotor material. Two kinds of miniaturized impact specimens were prepared, i.e., miniaturized specimen with side groove and without side groove. The correlation between ductile brittle transition temperature(DBTT) of full size impact specimen and that of miniaturized impact specimen was made. The characteristics of miniaturized impact specimens technique as well as fracture stress were discussed. Finally, we concluded that the characteristics of fracture stress change on aging time were similar to that of DBTT.

  • PDF

Ultrasonic Nonlinearity Parameter Due to Precipitate and Dislocation (석출물과 전위에 기인한 초음파 비선형성 파라미터)

  • Kim, Chung-Seok;Park, Ik-Keun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.7
    • /
    • pp.131-138
    • /
    • 2008
  • The microstructural effects on the ultrasonic nonlinearity were investigated in isothermally degraded ferritic 2.25Cr-1Mo steel and low cycle fatigued copper. The variation in ultrasonic nonlinearity (${\beta}/{\beta}_0$) was interpreted as resulting from microstructural changes supported by the electron microscopy and X-ray diffraction, in addition to the mechanical test (Victor's hardness and ductile-brittle transition temperature). The ultrasonic nonlinearity of 2.25Cr-1Mo steel increased abruptly in the initial 1,000 h of degradation, and then changed little due to the coarsening of carbide and precipitation of stable $M_6C$ carbide during isothermal degradation. The ultrasonic nonlinearity of copper increased with the fatigue cycles due to the evolution of dislocation cell substructure.

Effect of notch location on the toughness of narrow gap weldment (노치위치에 따른 Narrow Gap 용접부의 인성변화)

  • 김희진;신민태;원정규
    • Journal of Welding and Joining
    • /
    • v.4 no.1
    • /
    • pp.40-46
    • /
    • 1986
  • This investigation studied the toughness variations in the narrow gap weldment with the notch location. Specimens with the notch at the center of the weld metal showed the lowest toughness. As the location of notchmoves to fusion line, the impact properties improve reaching a maximum at the fusion boundaries. This improvement in toughness can be explained by the microstructural feature showing in the narrow gap weldment. "one pass/layer" technique performed in narrow gap welding results in the increased proportion of refined structure as approaching to fusion boundary from weld center and thus leave 100% refined structure along the fusion boundary. HAZ also shows 100% refined structure with respect to base metal structure accompanied with the significant suppression of ductile-brittle transition temperature.mperature.

  • PDF

A Study on Advanced Small Punch Test for Evaluation of Material Degradation in Weldment Microstructures (용접부 미세조직의 재질열화 평가를 위한 Advanced Small Punch 시험에 관한 연구)

  • 이동환;이송인;박종진;유효선
    • Journal of Welding and Joining
    • /
    • v.21 no.1
    • /
    • pp.99-106
    • /
    • 2003
  • This research was aimed to evaluate the material degradation with various microstructures of X20CrMoV121 steel weldment by Advanced Small Punch(ASP) test. Due to the regional limitation on constitutive structures, the minimized loading ball(${\varphi}1.5mm$) and bore diameter of lower die(${\varphi}3mm$) were designed for the ASP test. The micro-hardness test was also performed to assess the mechanical properties with artificial aging heat treatment. Material degradation was estimated by ductile-brittle transition temperature(DBTT). The results obtained from the ASP test were compared with those from conventional small punch(CSP) test and CVN impact test for several weldment microstructures. It was found that the ASP test clearly showed the microstructural dependance on the material degradation in the weldment.

Evaluation of Microstructural and Mechanical Properties of SA508 cl.3 Heat Affected Zone Produced by RPV Cladding

  • Lee, J.S.;Kim, I.S.;Kwon, S.C.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.867-868
    • /
    • 2004
  • The maximum width of HAZ of SA508치.3 steel produced by overlay RPV cladding was approximately 10 mm and it was composed of variety of microstructures with various grain size and precipitates. In addition, along the weld fusion line there formed a heavy carbide precipitation zone in the width of $20{\sim}30\;{\mu}m$. 2. As the specimen sampling position approached to the weld fusion line, the increase in yield and tensile strength was approximately 90 and 40 MPa, respectively. Meanwhile, the plastic fracture strain reduced from 14 to 8 percent. 3. The lowest SP energy and the highest ductile to brittle transition temperature in the HAZ were observed at the coarse- and fine-grained HAZ.

  • PDF

Segmented mandrel tests of as-received and hydrogenated WWER fuel cladding tubes

  • Kiraly, Marton;Horvath, Marta;Nagy, Richard;Ver, Nora;Hozer, Zoltan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2990-3002
    • /
    • 2021
  • The mechanical interaction between the fuel pellet and the cladding tube of a nuclear fuel rod is a very important for safety studies as this phenomenon could lead to fuel failure and release of radioactivity. To investigate the ductility of cladding tubes used in WWER type nuclear power plants, several mandrel tests were performed in the Centre for Energy Research (EK). This modified mandrel test was used to model the mechanical interaction between the fuel pellet and the cladding using a segmented tool. The tests were conducted at room temperature and at 300 ℃ with inactive as-received and hydrogenated cladding ring samples. The results show a gradual decrease in ductility as the hydrogen content increases, the ductile-brittle transition was seen above 1500 ppm hydrogen absorbed.

Characterization of Low-cycle Fatigue of Copper and Isothermal Aging of 2.25Cr Ferritic Steel by Ultrasonic Nonlinearity Parameter (초음파 비선형파라미터를 이용한 무산소동 저주기피로와 2.25Cr 페라이트강의 등온열화 평가)

  • Kim, Chungseok
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.35 no.5
    • /
    • pp.239-245
    • /
    • 2022
  • The purpose of this study is to evaluate the degree of microstructural change of materials using ultrasonic nonlinear parameters. For microstructure change, isothermal heat-treated ferritic 2.25Cr steel and low-cycle fatigue-damage copper alloy were prepared. The variation in ultrasonic nonlinearity was analyzed and evaluated through changes in hardness, ductile-brittle transition temperature, electron microscopy, and X-ray diffraction tests. Ultrasonic nonlinearity of 2.25Cr steel increased rapidly during the first 1,000 hours of deterioration and then gradually increased thereafter. The variation in non-linear parameters was shown to be coarsening of carbides and an increase in the volume fraction of stable M6C carbides during heat treatment. Due to the low-cycle fatigue deformation of oxygen-free copper, the dislocation that causes lattice deformation developed in the material, distorting the propagating ultrasonic waves, and causing an increase in the ultrasonic nonlinear parameters.

Property differences between GTAW and SMAW duplex stainless steel weld metal (이상계 스테인레스 강 용접부의 인성과 내식성 거동)

  • 백광기;김희진;안상곤
    • Journal of Welding and Joining
    • /
    • v.4 no.3
    • /
    • pp.58-71
    • /
    • 1986
  • Mechanical and corrosion property of duplex stainless steel weldments made by the GTAW and SMAW process were studied. Fracture toughness, general and local corrosion resistance of GTAW and SMAW weldments were evaluated in terms of Charpy V notch impact test, anodic polarization diagram, pitting corrosion rate, respectively. SMA weld metal showed much lower impact toughness and higher ductile-brittle transition temperature than GTA weld metal. Fractographic and EDX analysis on fracture surface of SMA weld metal demonstrated the existence of (Si, Ti), oxide in large amounts. Potentiodynamic anodic polarization diagram of GMA weld metal showed much lower passive current density than SMA weld metal in 4% $H_2/SO_4$ solution. And pitting corrosion rate test showed the same tendency. Relating the microstructure, chemistry and property, it can be concluded that GTA weld metal gives better toughness due to lower oxygen content, i.e. lower inclusion content, and better corrosion resistance due to higher Pitting Index(PI) than SMA weld metal.

  • PDF

A Study on High Temperature Fracture Behavior of Plasma Sprayed Zirconia/ NiCrAlY Coating System (지르코니아 /NiCrAlY 계 플라즈마 용사피막의 고온 파괴거동에 관한 연구)

  • Kim, Yeon-Jik;Im, Jae-Gyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.10
    • /
    • pp.3234-3242
    • /
    • 1996
  • This paper describes experimental results of modified small punch( MSP) test conducted to evaluate the fracure characteristics and mechanical properties of plasma sparayed zirconia ($ZrO_2$ stabilized with 8wt. % $Y_20_3$ : YSZ) NiCrAlY composite. The mixing ratios of YSZ/NiCrAlY were 0/100, 25/75, 50/50, 100/0 v.%. Test temperatures ranged from 293K to 1473K. This study is directed at development of thermal barrrier coating(TBC) system with superior heat resistance and mechanical properties. The microstructure and fracture process of the composite were examined by SEM and AE method. The mechanical properties of 100% YSZ were nearly independent of the temperatures tested in this study. In contrast, the NiCrAlY-containing composites showed a significant decrease of the mechanical properties above 1273K, showing a ductile- brittle transition behavior up to the temperature. Furthermore, it can seen that 25% YSZ/75% NiCrAlY composite gave the highest fracure strength and fracture energy among the mixing ratio tested over the temperature range.

Evaluation of Degradation Behavior of the Long-Term Serviced Boiler Header (장기 사용 보일러 헤더의 열화거동 평가에 관한 연구)

  • Gwon, Jae-Do;Bae, Yong-Tak;Choe, Seong-Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.7 s.178
    • /
    • pp.1673-1680
    • /
    • 2000
  • The degradation of a boiler header constructed by a material, 1Cr-0.5Mo steel in a fossil power plant is observed when the header is exposed for a long period to the high temperature and pressure. The present investigations are for evaluating the effect of the degradation on the material, such as its strength changes. Reheat-treated metal is used to compare the mechanical properties of the degraded and that of reheat-treated materials. Through the investigation, following results are obtained 1) the area ratio of ferrite in the reheat-treated material is larger than that of the degraded material, 2) the hardness and tensile strength of the degraded material are lower than that of the reheat-treated material, 3) the ductile-brittle transition temperature(DBTT) increased toward high temperature region, 4) the fatigue crack growth rate(FCGR) of the degraded material is higher than that of the reheat-treated material in the region of low ΔK value while FCGR of the both materials are similar in high ΔK region.