• 제목/요약/키워드: Ductile Design

검색결과 372건 처리시간 0.023초

지진하중에 대한 지하철구조물의 비선형 시간영역해석 (Nonlinear Time-Domain Analysis of Underground Subway Structure Subjected to Seismic Loadings)

  • 김재민;이중건
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.163-170
    • /
    • 2001
  • This paper presents results of nonlinear analyses for underground structures including both the soil-structure interaction and nonlinear behavior of concrete material. For this purpose, a hybrid method is employed, in which a dynamic analysis technique for a linear soil-structure interaction system and a general purpose FE program are combined in hybrid and practical manners. A couple of nonlinear analyses are carried out for framed structures in multi-layered half space soil medium. The yielding of concrete structure is considered by a multi-linear stress- strain relationship. The numerical results suggest that ductile design fur the intermediate columns in the underground framed structure is substantially important in aseismic design.

  • PDF

STS 316L 스테인리스강의 크리프 수명예측 (Creep Life Prediction of SUS 316L Stainless Steel)

  • 윤종호;황경충
    • 한국자동차공학회논문집
    • /
    • 제14권2호
    • /
    • pp.16-22
    • /
    • 2006
  • Stainless steel has widely been used in various industrial fields because it has high corrosion resistance. But, we have little design data about the creep life prediction of SUS316L stainless steel. Therefore, in this study, a series of creep tests and study on them under 16 constant stress and temperature combined conditions have been performed to get the creep design data and life prediction of SUS316L stainless steels and we have gotten the following results. First, the stress exponents decrease as the test temperatures increase. Secondly, the creep activation energy gradually decreases as the stresses become bigger. Thirdly, the constant of Larson-Miller parameters on this alloy is estimated about 10. And last, the creep rupture fractographs show the intergranular ductile fracture with many dimples.

이중 리브를 가진 냉간 압출품의 내.외부 결함 방지를 위한 공정 설계 (Process Design to Prevent Internal & External Defects of Cold Extruded Products with Double Ribs)

  • 김동진;김병민
    • 소성∙가공
    • /
    • 제8권6호
    • /
    • pp.612-619
    • /
    • 1999
  • Internal and external defects of an inner pulley for automobile air conditioner are investigated in this study. Inner pulley is a part of compressor clutch assembly of automobile air conditioner. In cold forging of inner pulley, the design requirement are to keep the same height of the inner rib and outer one and to make uniform distribution of hardness in the forged product. At the end of the forging of inner pulley, the piping defect as an external defect begins to form at the back center of the billet. The internal crack as an internal defect also occur at the adiabatic shear band which usually has maximum ductile fracture value. It is important to predict when the internal and external defects occur during the deformation process, in order to minimize the amount of discard that is generated. The finite element simulations are applied to analyze the defects. The validity of the computational results are examined by experiments. These computational results are in good agreement with the experimental ones.

  • PDF

Ultimate strength of long-span buildings with P.E.B (Pre-Engineered Building) system

  • Lee, Seong-Hui;Kim, Young-Ho;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1483-1499
    • /
    • 2015
  • With the improvement of the quality of construction materials and the development of construction technologies, large-scale long-span steel frame buildings have been built recently. The P.E.B system using tapered members is being employed as an economically-efficient long-span structure owing to its advantage of being able to distribute stress appropriately depending on the size of sectional areas of members. However, in December 2005 and in February 2014, P.E.B buildings collapsed due to sudden loads such as snow loads and wind gusts. In this study, the design and construction of the P.E.B system in Korea were analyzed and its structural safety was evaluated using the finite element analysis program to suggest how to improve the P.E.B system in order to promote the efficient and rational application of the system.

Bolted end plate connections for steel reinforced concrete composite structures

  • Li, Xian;Wu, Yuntian;Mao, Weifeng;Xiao, Yan;Anderson, J.C.;Guo, Yurong
    • Structural Engineering and Mechanics
    • /
    • 제24권3호
    • /
    • pp.291-306
    • /
    • 2006
  • In order to improve the constructability and meanwhile ensure excellent seismic behavior, several innovative composite connection details were conceived and studied by the authors. This paper reports experimental results and observations on seismic behavior of steel beam bolted to reinforced concrete column connections (bolted RCS or BRCS). The proposed composite connection details involve post tensioning the end plates of the steel beams to the reinforced concrete or precast concrete columns using high-strength steel rods. A rational design procedure was proposed to assure a ductile behavior of the composite structure. Strut-and-tie model analysis indicates that a bolted composite connection has a favorable stress transfer mechanism. The excellent capacity and behavior were then validated through five full-scale beam to column connection model tests.

Cold-formed austenitic stainless steel SHS brace members under cyclic loading: Finite element modelling, design considerations

  • YongHyun Cho;Fangying Wang;TaeSoo Kim
    • Steel and Composite Structures
    • /
    • 제47권1호
    • /
    • pp.135-145
    • /
    • 2023
  • This study presents a numerical investigation into the hysteretic behavior of cold-formed austenitic stainless steel square hollow section (SHS) brace members using a commercial finite element (FE) analysis software ABAQUS/Standard. The initial/post buckling and fracture life of SHS brace members are comprehensively investigated through parametric studies with FE models incorporating ductile fracture model, which is validated against the existing laboratory test results collected from the literature. It is found that the current predictive models are applicable for the initial buckling strengths of SHS brace members under cyclic loading, while result in significant inaccuracy in predictions for the post-buckling strength and fracture life. The modified predictive model is therefore proposed and the applicability was then confirmed through excellent comparisons with test results for cold-formed austenitic stainless SHS brace members.

연결부분 설계에 의한 일반교량의 내진성능 (Earthquake Resistance Capacity of a Typical Bridge by Connection Design)

  • 국승규
    • 한국전산구조공학회논문집
    • /
    • 제23권5호
    • /
    • pp.543-550
    • /
    • 2010
  • 내진설계는 타 설계의 요구사항, 즉 각 구조부재의 설계강도가 소요강도 이상이어야 한다는 것을 만족해야 하는 동시에 지진발생시 구조물의 항복과정을 규명하여 제시하여야 한다. 이러한 요구사항이 추가되는 이유는 타 하중과는 차별되는 지진하중의 불확실성이다. 이 연구에서는 일반교량을 해석대상교량으로 선정하고 연결부분의 설계를 수행하여 연성파괴메카니즘을 확보하는 과정을 제시하였다. 이와 같은 과정으로부터 구조부재의 강도 증가 또는 지진저감장치 도입 등의 비용증가 없이 타 설계에서 요구되는 구조부재의 강도 이내에서 내진성능을 확보할 수 있다는 것을 확인하였다.

플랜트 설비 지지용 대안 강구조 시스템의 내진성능 (Seismic Performance of Alternative Steel Structural Systems for an Equipment-Supporting Plant Structure)

  • 곽병훈;안숙진;박지훈
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.13-24
    • /
    • 2023
  • In this study, alternative seismic force-resisting systems for plant structure supporting equipment were designed, and the seismic performance thereof was compared using nonlinear dynamic analysis. One alternative seismic force-resisting system was designed per the requirement for ordinary moment-resisting and concentrically braced frames but with a reduced base shear. The other seismic force-resisting system was designed by accommodating seismic details of intermediate and unique moment-resisting frames and special concentrically braced frames. Different plastic hinge models were applied to ordinary and ductile systems based on the validation using existing test results. The control model obtained by code-based flexible design and/or reduction of base shear did not satisfy the seismic performance objectives, but the alternative structural system did by strengthened panel zones and a reduced effective buckling length. The seismic force to equipment calculated from the nonlinear dynamic analysis was significantly lower than the equivalent static force of KDS 41 17 00. The comparison of design alternatives showed that the seismic performance required for a plant structure could be secured economically by using performance-based design and alternative seismic-force resisting systems adopting minimally modified seismic details.

전단벽 구조물의 모멘트 저항능력에 관한 비탄성 해석모델개발 (Development of Analytical Model to Predict the Inelastic Moment Capacity of Reinforced Concrete and Masonry Shear Wall)

  • 홍원기;이호범;변근주
    • 콘크리트학회지
    • /
    • 제5권4호
    • /
    • pp.123-134
    • /
    • 1993
  • 큰 수평하중을 견딜 수 구조물의 해석 및 설계는 구조물의 거동에 대한 완전한 이해에 바탕을 두는 설계기법의 측면에서 이루어져야 한다. 본 연구는 일반적인 구조물, 특히 콘크리트 전단벽 구조물의 설계와 해석에 적용될 수 있으며, 실험에 의해 그 정도가 확인되는 수치적 해석 모형을 개발하는데 있다. 즉 설계방법을 이해하고 개선하므로써 구조물의 안전성을 보장해 줄 수 있는 해석모형을 제시하는 것이 본연구의 기본 목적이다. 이상적으로 이러한 안전성을 모형내에 확보하기 위해서 구조물의 연성거동을 확인할 수 있도록 하였으며 면내하중을 받는 전단벽에 대해 다수의 실험을 통해, 개발된 해석모형의 정확도를 입증하였다. 최종적으로 실험검증을 통한 해석모형을 콘크리트조적도 전단벽의 거동을 잘 예측하였으며, 또한 실무에 관련된 설계화 해석에 응용될 수 있도록 시도되어 그 설계예와 함께 수치적 해석모형의 실용성을 보였다.

Evaluation and Improvement of Deformation Capacities of Shear Walls Using Displacement-Based Seismic Design

  • Oh, Young-Hun;Han, Sang-Whan;Choi, Yeoh-Soo
    • International Journal of Concrete Structures and Materials
    • /
    • 제18권1E호
    • /
    • pp.55-61
    • /
    • 2006
  • RC shear walls are frequently used as lateral force-resisting system in building construction because they have sufficient stiffness and strength against damage and collapse. If RC shear walls are properly designed and proportioned, these walls can also behave as ductile flexural members like cantilevered beams. To achieve this goal, the designer should provide adequate strength and deformation capacity of shear walls corresponding to the anticipated deformation level. In this study, the level of demands for deformation of shear walls was investigated using a displacement-based design approach. Also, deformation capacities of shear walls are evaluated through laboratory tests of shear walls with specific transverse confinement widely used in Korea. Four full-scale wall specimens with different wall boundary details and cross-sections were constructed for the experiment. The displacement-based design approach could be used to determine the deformation demands and capacities depending on the aspect ratio, ratio of wall area to floor plan area, flexural reinforcement ratio, and axial load ratio. Also, the specific boundary detailing for shear wall can be applied to enhance the deformation capacity of the shear wall.