• Title/Summary/Keyword: Dual-frequency

Search Result 1,202, Processing Time 0.03 seconds

COMPARISON OF SHEAR BOND STRENGTH AND MARGINAL LEAKAGE OF RESIN MODIFIED GLASS IONOMER CEMENTS (강화형 글라스 아이오노머 합착용 시멘트의 접합강도 및 변연누출에 대한 연구)

  • Park, Hye-Yang;Oh, Nam-Sik;Lee, Keun-Woo;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.647-661
    • /
    • 1997
  • The resin modified glass ionomer cements(RMGICs) have been used for years since 1989. Recently it has been developed for luting of fixed restorations. To evaluate the bond strength and marginal leakage of RMGICs for luting usage, the 80 extracted human molars which had uniform area of exposed dentin were cemented with 3 types of RMGICs(Fuji Duet, Advance, Vitremer), a conventional Glass Ionomer Cement(GIC-Fuji I), and a resin cement (Panavia 21) to base metal alloy(Ni-Cr-Be). After thermocycling the specimens were immersed in basic fuschin dye for measuring marginal leakage. The shear bond strength was measured with Instron and the maximum dye penetration was measured to 0.1mm. The types of fractured patterns were determined with stereoscope(${\times}7.5$). The results are as follows. 1. The difference between 3 RMGICs and a conventional GIC in shear bond strength was not statistically significant. It seemed that RMGICs had lower shear bond strength than resin cement. (p<0.01) 2. The mean scores of marginal leakage had no significant difference between the resin cement and 3 RMGICs but it was much higher in conventional GIC than the RMGICs (p<0.05) 3. It was determined that the manufacturer and the methods of dentin pretreatment determined the pattern of fracture surfaces and the frequency of adhesive failure between teeth and 3 RMGICs standed as in following order - Vitremer, Advance, Fuji Duet. (p<0. 01) When the fracture pattern was analyzed, it could be said that the materials and the method of dentin pretreatment have much effect on bonding states. This means that the dentin bonding agents should be improved. But the limited products in this experiment can not evaluate the physical properties of the entire RMGICs. Therefore a further study which can evaluate various RMGICs should be in progress to develope better cements.

  • PDF

Detection of Herpes Simplex Virus, Varicella-Zoster Virus and Human Herpes Virus-6 by PCR in Cerebrospinal Fluid from Hospitalized Adult Patients with Aseptic Meningitis or Encephalitis (무균성 뇌막염과 뇌염으로 입원한 성인 환자 뇌척수액에서 중합효소 연쇄반응에 의한 HSV, VZV, HHV-6의 검출)

  • Park, Hae-Kyung;Woo, So-Youn;Kim, Hyun-Jin;Chong, Young-Hae
    • The Journal of Korean Society of Virology
    • /
    • v.30 no.3
    • /
    • pp.171-178
    • /
    • 2000
  • Herpes simplex virus, Varicella zoster virus and Human herpes virus-6 caused central nervous system infections and latent infections but there is no data of the 3 viruses being tested from the same cerebrospinal fluid samples with aseptic meningitis or encephalitis in adults patients. These viruses produced similar neurologic symptoms but difficulties existed in differentiating of etiologic agents and therefore the viruses needed to be detected in the early state. Herpes simplex virus encephalitis (HSVE) in adults, if not treated promptly was fatal. If treated with antiviral drugs in the early phase of encephalitis, neurologic sequales decreased by 65%. Recently, a PCR method for detection of HSVE with CSF was developed. VZV primary and secondary infections caused neurologic symptoms of encephalitis or meningitis. The second frequency of adult encephalitis that caused VZV were reported. HHV-6 caused CNS latent infection that was studied with normal adults brains. But there is no data of HSV, VZV and HHV-6 for aseptic meningitis and encephalitis of Korean adults through etiologic study. We cultured CSFs on HEp-2 cells and simultaneously tested for HSV PCR, VZV nested PCR and HHV-6 PCR with 8 specific primers. The PCR results of CSF from meningitis Korean adults were 13/19 (68.4%) for HSV, 10/19 (52.6%) for VZV and 12/19 (63.2%) for HHV-67/19 (36.8%) cases were triple infected HSV PCR, VZV PCR and HHV-6 PCR positive; 3/19 (15.8%) cases were dual infected HSV PCR and HHV-6 PCR positive; 1119 (0.5%) cases was VZV PCR positive. Strong viral DNA amplification of CSF means a causative virus may be present in aseptic meningitis or encephalitis patients and may cause clinical neurologic symptoms. HSV and HHV-6 viruses detection rate were higher than VZV by PCR with CSFs.

  • PDF

The Relation between Bone Mineral Density and Lifestyle in College Students (일부 대학생의 골밀도와 생활습관간의 관련성)

  • Kang, Tae-Hun;Lee, Mu-Sik;Bae, Suk-Hwan;Kim, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.429-434
    • /
    • 2016
  • This study was performed in order to identify the relation between bone nineral density and life styles of some of Korean colleage students. A total of 121 college students were assessed through bone mineral density test on femoral neck and lumbar spine using dual energy X-ray absorptiometry(DEXA). The survey about their lifestyles with a self-rating questionnaire, was conducted from September 2014 to November 2014. SPSS 18.0 Program was used for those research data analyses such as the frequency analysis, the cross analysis. The percentage of the osteoporisis, osteopenia and normal groups were 0.0%, 24.8% and 75.2%. BMI, Regular menstrual cycle, Walking and Regular exercise in adolescence were positively related with T-score. But Using time of electronic devices was negative related with T-score. It can be concluded that desirable life style in time of college students and adolescence is important for their bone health. The necessity of preparing guideline for preventing bone disease in old age connected with the school curriculum should be recognized to the public and educational authorities.

Advanced LWIR Thermal Imaging Sight Design (원적외선 2세대 열상조준경의 설계)

  • Hong, Seok-Min;Kim, Hyun-Sook;Park, Yong-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.3
    • /
    • pp.209-216
    • /
    • 2005
  • A new second generation advanced thermal imager, which can be used for battle tank sight has been developed by ADD. This system uses a $480\times6$ TDI HgCdTe detector, operating in the $7.7-10.3{\mu}m$ wavelength made by Sofradir. The IR optics has dual field of views such as $2.67\times2^{\circ}$ in NFOV and $10\times7.5^{\circ}$ in WFOV. And also, this optics is used for athermalization of the system. It is certain that our sensor can be used in wide temperature range without any degradation of the system performance. The scanning system to be able to display 470,000 pixels is developed so that the pixel number is greatly increased comparing with the first generation thermal imaging system. In order to correct non-uniformity of detector arrays, the two point correction method has been developed by using the thermo electric cooler. Additionally, to enhance the image of low contrast and improve the detection capability, we have proposed the new technique of histogram processing being suitable for the characteristics of contrast distribution of thermal imagery. Through these image processing techniques, we obtained the highest quality thermal image. The MRTD of the LWIR thermal sight shows good results below 0.05K at spatial frequency 2 cycles/mrad at the narrow field of view.

Dual Effect of $H_2O_2$ on the Regulation of Cholecystokinin-induced Amylase Release in Rat Pancreatic Acinar Cells

  • An, Jeong-Mi;Rhie, Jin-Hak;Seo, Jeong-Taeg
    • International Journal of Oral Biology
    • /
    • v.31 no.4
    • /
    • pp.127-133
    • /
    • 2006
  • [ $H_2O_2$ ], a member of reactive oxygen species (ROS), is known to be involved in the mediation of physiological functions in a variety of cell types. However, little has been known about the physiological role of $H_2O_2$ in exocrine cells. Therefore, in the present study, the effect of $H_2O_2$ on cholecystokinin (CCK)-evoked $Ca^{2+}$ mobilization and amylase release was investigated in rat pancreatic acinar cells. Stimulation of the acinar cells with sulfated octapeptide form of CCK (CCK-8S) induced biphasic increase in amylase release. Addition of $30\;{\mu}M\;H_2O_2$ enhanced amylase release caused by 10 pM CCK-8S, but inhibited the amylase release induced by CCK-8S at concentrations higher than 100 pM. An ROS scavenger, $10\;{\mu}M$ Mn(III)tetrakis(4-benzoic acid)porphyrin chloride, increased amylase release caused by CCK-8S at concentrations higher than 100 pM, although lower concentrations of CCK-8S-induced amylase release was not affected. To examine whether the effect of $H_2O_2$ on CCK-8S-induced amylase release was exerted via modulation of intracellular $Ca^{2+}$ signaling, we measured the changes in intracellular $Ca^{2+}$ concentration $([Ca^{2+}]_i)$ in fura-2 loaded acinar cells. Although $30\;{\mu}M\;H_2O_2$ did not induce any increase in $[Ca^{2+}]_i$ by itself, it increased the frequency and amplitude of $[Ca^{2+}]_i$ oscillations caused by 10 pM CCK-8S. However, $30\;{\mu}M\;H_2O_2$ had little effect on 1 nM CCK-8S-induced increase in $[Ca^{2+}]_i$. ROS scavenger, 1 mM N-acetylcysteine, did not affect $[Ca^{2+}]_i$ changes induced by 10 pM or 1 nM CCK-8S. Therefore, it was concluded that $30\;{\mu}M\;H_2O_2$ enhanced low concentration of CCK-8S-induced amylase release probably by increasing $[Ca^{2+}]_i$ oscillations while it inhibited high concentration of CCK-8S-induced amylase release.

The Influence of Plasma Surface Modification on Frictional Property of Natural Rubber Vulcanizates

  • Nah, C.;Kim, D.H.;Mathew, G.;Jeon, D.J.;Jurkowski, B.;Jurkowska, B.
    • Elastomers and Composites
    • /
    • v.39 no.1
    • /
    • pp.12-22
    • /
    • 2004
  • The plasma surface modification of natural rubber vulcanizate was carried out using chlorodifluoromethane in a radio-frequency (13.56 MHz) electrodeless bell type plasma reactor. The modification was qualitatively assessed by Fourier transform infrared spectroscopy. The frictional force of the plasma-treated surface was found to decrease with the time of plasma treatment. An increase in the surface polarity, as evidenced by the decrease in contact angle of a sessile drop of water and ethylene glycol on the natural rubber vulcanizate surface, was noted with the plasma modification. In the case of similar plasma treatment of glass surface, only a reduction in the polarity was observed. The use of geometric and harmonic mean methods was found to be useful to evaluate the London dispersive and specific components of surface free energy. Irrespective of the method used for evaluation, an increasing trend in the surface free energy was noted with increasing plasma treatment time. However, the harmonic mean method yielded comparatively higher values of surface free energy than the geometric mean method. The plasma surface modification was found to vary the frictional coefficient by influencing the interfacial, hysteresis and viscous components of friction in opposing dual manners.

Design of a Double-Faced Monopole Antenna Using the Coupling Effect of Induced Currents (유도 전류의 커플링 효과를 이용한 모노폴 안테나 설계)

  • Choi, Young;Lee, Seungwoo;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.12
    • /
    • pp.1327-1336
    • /
    • 2012
  • In this paper, the dual-faced monopole antenna, which is arranged by numerous rectangular ring patches in sequence for the multi-bands is proposed. The ring type structure of the patch can be increased the bandwidth. Therefore the bandwidth and beam width are improved by using multiple arrayed patches. When the ring type patches are inserted serially, the resonance frequencies are occurred by the current flow from the first ring patch. It is possible because the gap between the patches is very narrow. In addition, if the patches are composed on the same plane as the feed-line, fabrication could be very difficult because the gap between the patches is extremely narrow. The thickness and permittivity of the antenna, moreover, are very important parameters because both sides of the substrate are used. We finally found the optimal thickness and permittivity to generate the coupling effect by simulation. All patches are consisted of 4-steps which the patch size was decreased 85 % by each step. In conclusion, the resonant frequency bands are 1.75~2.6 GHz(850 MHz), 3.24~3.46 GHz(220 MHz), 3.8~4.0 GHz(200 MHz), and 4.4~4.9 GHz(500 MHz).

Development of Quad-Band Printed Monopole Antenna Using Coupling Effect of Dual Rectangular Rings and L-Slots on the GND (이중 사각 링 패치 결합효과와 접지면 L-슬롯을 이용한 4중 대역 인쇄형 모노폴 안테나 개발)

  • Shin, Yong-Jin;Lee, Seungwoo;Kim, Nam
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.10
    • /
    • pp.1040-1049
    • /
    • 2014
  • In this paper, a quad-band antenna for DCS1800, PCS1900, WCDMA, WLAN and Mobile WiMAX application is proposed. The proposed antenna is a printed monopole structure, and consists of two rectangular ring-shaped radiating patches on the front side and two different size of L-shaped slots on the back side(ground plane). Two rectangular ring radiation patches are respectively resonant at 2 GHz and 3.5 GHz bands, and additional resonance is occurred at 5.3 GHz by the coupling effect between two ring patches. In addition, the optimized matching characteristic is obtained by controlling the gaps. Also, by adding two L-slots on the ground plane, additional resonant frequency band of 5.6 GHz is occurred. Finally the measured bandwidths of the proposed antenna below -10 dB return loss are 1,200 MHz(1.6~2.8 GHz), 800 MHz(3.2~4.0 GHz), 300 MHz(5.14~5.44 GHz), and 690 MHz(5.56~6.25 GHz). The radiation patterns have the omni-directional characteristic, and the measured antenna average gains at resonant bands are 0.86~4.07 dBi.

Precise Relative Positioning for Formation Flying Satellite using GPS Carrier-phase Measurements (GPS 반송파 위상을 사용한 편대비행위성 상대위치결정 연구)

  • Park, Jae-Ik;Lee, Eunsung;Heo, Moon-Beom
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.12
    • /
    • pp.1032-1039
    • /
    • 2012
  • The present paper deals with precise relative positioning of formation satellites with long baseline in low Earth orbit making use of L1/L2 dual frequency GPS carrier phase measurements. Kinematic approach means to describe the motion of objects without taking its mass/dynamics model into consideration. The advantage of the kinematic approach is that information about dynamics of the system is not applied, which gives more flexibility and could improve the scientific interest of the observations made by the mission. The ionosphere terms, which are not canceled by double differenced measurement equation in the case of the long baseline, are explicitly estimated as unknown parameters by extended Kalman filter. The estimated float ambiguities by EKF are solved by existing efficient integer vector search strategy under integer least square condition. For the integer vector search, we employ well known MLAMBDA. Finally, The feasibility and accuracy of processing scheme are demonstrated using the GPS measurements for two satellites in low Earth orbit separated by baselines of 100 km.

The clinical usefulness of 64 channel MDCT and 128 channel DSCT in coronary CT angiography (관상동맥 전산화단층촬영에서 64 channel MDCT와 128 channel DSCT의 임상 유용성 평가)

  • Choi, Nam-Gil;Choi, Jae-Seong;Han, Jae-Bok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4411-4417
    • /
    • 2010
  • This study was retrospectively to compare the exposure dose and the imaging quality in coronary CT angiography by using the 64 channel multidetector computed tomography and the 128 channel DSCT. Effective dose was calculated dose length product (DLP) by multiplied the convention factor of chest (0.017). Imaging quality was assessed by radiologists using the 5-point Likert scale. The DLP was ranged from 851 to $1277mGy{\cdot}cm$ (mean: 17.23 mSv) in the 64 channel MDCT and from 82 to $110mGy{\cdot}cm$ (mean: 1.58 mSv) in the of 128 channel DSCT, respectively. The score of imaging quality was respectively $3.31{\pm}0.62$ in 64 channel MDCT and $4.05{\pm}0.46$ in the 128 channel DSCT. The exposure dose of 128 channel DSCT has decreased 1ess 1/10. The score of imaging quality was significant difference between two modalities and the frequency (>4 good) in the 128 channel DSCT is about three times than that of the 64 channel MDCT. Therefore, the 128 channel DSCT in coronary CT angiography is clinically more effective modality for both investigators and patients.