• 제목/요약/키워드: Dual-control

검색결과 1,536건 처리시간 0.024초

확률제어 기법을 이용한 불규칙 진동계의 모델추종 이중제어기 설계 (Model Following Dual Controller Design for Random Vibrating System Using a Stochastic Controller Technique)

  • 이종복;김홍윤;안준영;허훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.525-528
    • /
    • 2005
  • Much of the study has been dong on the design of dual controller that guarantee the stability and improvement of the system performance. A dual controller concept is proposed to consist of first controller estimates the control law and second controller suppresses the combined noises due to numerical error and internal noise as well. These irregular disturbances are not only increasing the fatigue but also destabilize the system because of unwanted output performance. The 'stochastic controller' is used to suppress the irregular random disturbance. Simulation is conducted to reveal that the proposed dual stochastic controller is highly efficient one to control a system hybrid noises.

  • PDF

확률제어 기법을 이용한 불규칙 진동계의 모델추종 이중제어기 설계 (Model Following Dual Controller Design For Random Vibrating System Using a Stochastic Controller Technique)

  • 이종복;김흥윤;안준영;허훈
    • 한국소음진동공학회논문집
    • /
    • 제15권6호
    • /
    • pp.757-763
    • /
    • 2005
  • Much of the study has been done on the design of dual controller that guarantee the stability and improvement of the system performance. A dual controller concept is proposed to consist of first controller estimates the control law and second controller suppresses the combined noises due to numerical error and internal noise as well. These Irregular disturbances are not only increasing the fatigue but also destabilize the system because of unwanted output Performance. The 'stochastic controller' is used to suppress the irregular random disturbance. Simulation is conducted to reveal that the proposed dual stochastic controller is highly efficient one to control a system hybrid noises.

HDD의 2단구동기를 이용한 트랙 추종 제어의 실험적 고찰 (Experimental Considerations in Tracking Control of HDD Dual Stage Actuator)

  • 박성준;박노철;양현석
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.237-242
    • /
    • 2000
  • The areal recording density of HDD(Hard Disk Drive) has been increasing by about 60% a year. In order to achieve high areal density, less track pitch is expected and more servo bandwidth is required. Dual stage actuator and servo controller for HDD have been suggested for achieving high track density as a possible solution. Dual-loop servo system is generally classified into a two-input-two-output system, but if we use an estimator for a two-input-two-output system, it can be converted into two input one output system. Since we can't control the dual stage servo system by the classical method, it requires a special technique; for example, Parallel Loop System, Master-Slave Loop System, Decoupled Master-Slave Loop System, and Dual Feedback Loop System. In this paper, we performed experimental evaluations of several types of control algorithm. Further experiments will be made in the future.

  • PDF

Outage Performance of Selective Dual-Hop MIMO Relaying with OSTBC and Transmit Antenna Selection in Rayleigh Fading Channels

  • Lee, In-Ho;Choi, Hyun-Ho;Lee, Howon
    • Journal of Information Processing Systems
    • /
    • 제13권5호
    • /
    • pp.1071-1088
    • /
    • 2017
  • For dual-hop multiple-input multiple-output (MIMO) decode-and-forward relaying systems, we propose a selective relaying scheme that uses orthogonal space-time block code (OSTBC) and transmit antenna selection with maximal-ratio combining (TAS/MRC) or vice versa at the first and second hops, respectively. The aim is to achieve an asymptotically identical performance to the dual-hop relaying system with only TAS/MRC, while requiring lower feedback overhead. In particular, we give the selection criteria based on the antenna configurations and the average channel powers for the first and second hops, assuming Rayleigh fading channels. Also, the numerical results are shown for the outage performance comparison between the dual-hop DF relaying systems with the proposed scheme, only TAS/MRC, and only OSTBC.

DSPs(TMS320C80)을 이용한 8축 듀얼 아암 로봇의 실시간 퍼지제어 (Real-Time Fuzzy Control for Dual-Arm with 8 Joints Robot Using the DSPs(TMS320C80))

  • 한성현;김종수
    • 한국공작기계학회논문집
    • /
    • 제13권1호
    • /
    • pp.35-47
    • /
    • 2004
  • In this paper presents a new approach to the design and real-time implementation of fuzzy control system based-on digital signal processors(DSP:IMS320C80) in order to improve the precision and robustness for system of industrial robot(Dual-Arm with 8 joint Robot). The need to meet demanding control requirement in increasingly complex dynamical control systems under significant uncertainties, leads toward design of intelligent manipulation robots. The IMS320C80 is used in implementing real time fuzzy control to provide an enhanced motion control for robot manipulators. In this paper, a Self-Organizing Fuzzy Controller(SOFC) for the industrial robot manipulator with a actuator located at the base is studied. A fuzzy logic composed of linguistic conditional statements is employed by defining the relations of input-output variables of the controller. In the synthesis of a FLC(Fuzzy Logic Controller), one of the most difficult problems is the determination of linguistic control rules from the human operators. To overcome this difficult SOFC is proposed for a hierarchical control structure consisting of basic and high levels that modify control rules. The proposed SOFC scheme is simple in structure, Int in computation, and suitable for implementation of real-time control. Performance of the SOFC is illustrated by simulation and experimental results for a Dual-Arm robot with eight joints.

Decoupled Type의 초정밀 이중 서보의 제어에 관한 연구 (Control of Decoupled Type High Precision Dual-Servo)

  • 남병욱;김기현;최영만;김정재;이석원;권대갑
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.43-50
    • /
    • 2006
  • Recently, with rapid development of semiconductor and flat panel display, the manufacturing equipments are required to have large travel range, high productivity, and high accuracy. In this paper, an ultra precision decoupled dual servo (DDS) system is proposed to meet these requirements. And a control scheme for the DDS is studied. The proposed DDS consists of a $XY{\Theta}$ fine stage for handling work-pieces precisely and a XY coarse stage for large travel range. The fine stage consists of four voice coil motors (VCM) and air bearing guides. The coarse stage consists of linear motors and air bearing guides. The DDS is mechanically decoupled between coarse stage and fine stage. Therefore, both stages must be controlled independently and the performance of the DDS is mainly determined by the fine stage. For high performance tracking, the controller of fine stage consists of time delay control (TDC) and perturbation observer while the controller of coarse stage is TDC alone. With these individual controllers, two kinds of dual-servo control strategies are suggested: master-slave type and parallel type. By simulations and experiments, the performances of two dual-servo control strategies are compared.

High-Reliability Three-Phase Dual-Buck Grid-Connected Inverter without Shoot-Through Problem

  • Fu, Zhenbin;Feng, Zhihua;Chen, Xi;Zheng, Xinxin
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.454-462
    • /
    • 2019
  • When compared to traditional bridge-type inverters, the dual-buck inverter has a higher reliability due to the fact that its bridge legs do not have a shoot-through problem. In this paper, the working principle of the dual-buck inverter is analyzed. A comparison of the working modes under full-cycle and half-cycle control is discussed. With half-cycle control, the inverter can realize a higher efficiency. However, this results in current zero-crossing distortion. The corresponding control strategy of the dual-buck inverter is proposed in order to realize both high efficiency and low current harmonic distortion. In addition, the system stability is analyzed. Dead-time is unnecessary due to the advantages of the topology. Thus, the current harmonic distortion can be further reduced. An inverter with the proposed control strategy has the advantages of high reliability, high efficiency and low current harmonic distortion. Finally, simulation and experimental results are given to verify the theoretical analysis.

Discrete-Time Queuing Analysis of Dual-Plane ATM Switch with Synchronous Connection Control

  • Choi, Jun-Kyun
    • ETRI Journal
    • /
    • 제19권4호
    • /
    • pp.326-343
    • /
    • 1997
  • In this paper, we propose an ATM switch with the rate more than gigabits per second to cope with future broadband service environments. The basic idea is to separate the connection control flow from the data information flow inside the switch. The proposed switch has a dual-plane switch matrix with the synchronous control algorithm. The queuing behaviors of the proposed switch are shown by the discrete-time queuing analysis. Numerical analyses are taken both in the non-blocking crossbar switch and the banyan switch with internal blocking. Results show that a proposed dual-plane $16{\times}16$ switch would have the acceptable performance with maximum throughput of about 95 percent.

  • PDF

VAV 터미널 박스의 최소풍량 제어방식 비교 연구 (A Study on the Comparison Analysis of Minimum Airflow Control Logic of VAV Terminal Box)

  • 조영흠;강수현;성윤복
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.96-102
    • /
    • 2012
  • The minimum airflow of VAV terminal boxes is a key factor for comfort, indoor air quality(IAQ) and energy cost. If the minimum airflow is not reasonable, it would waste energy and make IAQ problems. There are two types of VAV terminal box control logic. One is the single maximum, another is the dual maximum control logic. Dual maximum control logic is more efficiency way to reduce the energy consumption. It has a minimum airflow set point and a heating maximum set point. It allows the minimum airflow set point to be much lower than single maximum control logic. A building simulation was conducted to evaluate the energy consumption and the IAQ according to the control logic of the V AV terminal box. In the simulation, dual maximum control logic can save the energy up to 6.5% compared to the single maximum control logic.

듀얼 레이트를 갖는 지능형 디지털 제어기 설계 (Design of Intelligent Digital Controller with Dual-Rate Sampling)

  • Kim, Do-Wan;Joo, Young-Hoon;Park, Jin-Bae
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 2004년도 춘계학술대회 학술발표 논문집 제14권 제1호
    • /
    • pp.559-562
    • /
    • 2004
  • In this paper, a new dual-rate digital control technique for the Takagi-Sugeno (T-S) fuzzy system is suggested. The proposed method takes account of the stabilizablity of the discrete-time T-S fuzzy system at the fast-rate sampling points. Our main idea is to utilize the lifted control input. The proposed approach is to obtain the dual-rate discrete-time T-S fuzzy system by discretizing the overall dynamics of the T-S fuzzy system with the lifted control, and then to derive the sufficient conditions for the stabilization in the sense of the Lyapunov asymptotic stability for this system.

  • PDF