• 제목/요약/키워드: Dual wavelength laser

검색결과 33건 처리시간 0.026초

Tunable Channel Spacing of Dual-wavelength Erbium-doped Fiber Ring Laser using a Single Fiber Bragg Grating with Two Coil Heaters

  • Sohn, Kyung-Rak;Kim, Hyung-Pyo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.153-158
    • /
    • 2009
  • Stable and tunable dual-wavelength erbium-doped fiber ring laser(EDFL) using a single fiber Bragg grating(FBG) and two coil heaters is proposed and demonstrated. Installing two identical coils into a single FBG, the FBG is symmetrically divided into two different portions. While a current supply to the coil, the refractive index of the FBG under the coil is changed. The FBG can operate as a joint of two different FBGs. Due to the thermo-optic effect of a fiber, the resonance wavelength split into two peaks. The spacing between two adjacent channels was changed as much as the difference of heating power. It was tuned up to 3 nm of wavelength under the electrical power with a 1000 mW. Moreover, the lasing wavelength can be individually tuned without influencing to the adjacent channel.

High Repetition Wavelength-locked 878.6 nm LD Dual-end-pumped Nd:YVO4 1064 nm Laser

  • Li, Yue;Yu, Yong-Ji;Wang, Yu-Heng;Liu, Hang;Liu, He-Yan;Jin, Guang-Yong
    • Current Optics and Photonics
    • /
    • 제2권6호
    • /
    • pp.582-588
    • /
    • 2018
  • A $Nd:YVO_4$ laser dual-end-pumped by a wavelength-locked 878.6 nm laser diode is presented. At the repetition rate of 500 KHz, the absorbed pump power of 58 W, an output power of 26.1 W at 1064 nm is obtained, corresponding to an optical-optical efficiency of 45%. The pulse width is 44.2 ns. Meanwhile, the effects of traditional 808 nm pumping and 878.6 nm dual-end-pumping on the output laser beam quality and pulse width are compared and analyzed in an experiment.

파장 가변 및 스위칭이 가능한 쌍파장 어븀 첨가 광섬유 레이저 (Dual Wavelength Erbium-doped Fiber Laser with Lasing Wavelength Switchability and Tunability)

  • 박상오;심영보;윤민석;추수호;김현주;권오장;한영근
    • 한국광학회지
    • /
    • 제21권5호
    • /
    • pp.181-184
    • /
    • 2010
  • 본 논문에서는 파장 가변과 동시에 스위칭이 가능한 쌍파장 어븀 첨가 광섬유 레이저를 실험적으로 구현하였다. 희토류 첨가 광섬유를 이득 매질로 사용하고 두 개의 선형 공진기를 중첩하여 파장 스위칭 효과를 구현하였다. 음향광학 변조기로 두 레이저 발진 파장들 사이에 선택적으로 스위칭하는 기능을 가지면서 동시에 광섬유 격자에 인장력 및 수축력을 인가하여 발진 파장을 가변할 수 있는 기능성 쌍파장 광섬유 레이저를 구현하였다. 제안된 파장 가변형 쌍파장 스위칭 레이저는 높은 소광비와 가변성, 넓은 가변 대역폭, 그리고 빠른 안정응답시간 등 이전의 기술에 비해 더 좋은 장점들을 가지고 있다. 파장 스위치를 하는 모든 경우에 대해 40 dB이상의 높은 소광비를 가지는 고성능의 광섬유 레이저를 구현하였다. 제안된 쌍파장 광섬유 레이저의 출력은 안정적이고 출력 변동은 0.6 dB 이하로 측정되었다. 발진 파장의 가변성 변화는 ~7.2 nm/$m^{-1}$로 측정되었다.

Widely Tunable 1.55-${\mu}m$ Detuned Dual-Mode Laser Diode for Compact Continuous-Wave THz Emitter

  • Kim, Nam-Je;Leem, Young-Ahn;Ko, Hyun-Sung;Jeon, Min-Yong;Lee, Chul-Wook;Han, Sang-Pil;Lee, Dong-Hun;Park, Kyung-Hyun
    • ETRI Journal
    • /
    • 제33권5호
    • /
    • pp.810-813
    • /
    • 2011
  • We report the use of a widely tunable detuned dual-mode laser diode (DML) as a compact and portable continuous-wave THz emitter. The wavelength difference between the two lasing modes of this DML can be tuned from 2.4 nm to 9.3 nm by using integrated microheaters. The power difference between these modes is less than 1 dB, and the side-mode suppression ratio is greater than 30 dB over the entire tuning range.

Clinical Applications of a Non-ablative Fractional Dual Laser (1550/1927 nm)

  • Chang, Ho Sun;Lim, Nam Kyu
    • Medical Lasers
    • /
    • 제9권2호
    • /
    • pp.110-118
    • /
    • 2020
  • The non-ablative fractional dual laser is equipped with two types of lasers, 1550 nm and 1927 nm in one device, and was approved by the United States Food and Drug Administration in 2013. The advantages of the non-ablative fractional laser (NAFL) include fewer side effects such as erythema, edema, post-laser pigmentation, and scab formation. Thus, the NAFL is preferred by both practitioners and consumers because it is convenient and safe for use. The 1550 nm erbium glass and 1927 nm thulium lasers are representative NAFLs that have been developed separately and are often used as a single-wavelength laser with proven clinical efficacy in various indications. The 1550 nm wavelength laser penetrates the dermis layer and the 1927 nm wavelength laser is effective for epidermal lesions. Therefore, targeting the skin layer can be easily achieved with both the 1550 and 1927 nm lasers, respectively, or in combination. Clinically, the 1550 nm laser is effective in the treatment of mild to moderate sagging and wrinkles, scars, and resurfacing. The 1927 nm laser improves skin texture and treats skin pigmentation and wounds. It can also be used for drug delivery. The selection and utilization rate of NAFL has been increasing in recent times, due to changes in lifestyle patterns and the need for beauty treatments with fewer side effects and short downtime. In this study, we present a plan for safe and effective laser therapy through a review of literature. Clinical applications of the multifunctional NAFL are also described.

High Power Switchable Dual-Wavelength Linear Polarized Yb-Dozped Fiber Laser around 1120 nm

  • Liu, Xiaojuan;Huang, Bangcai;Wei, Gongxiang;Han, Kezhen;Huang, Yan;Liu, Fangfang
    • Journal of the Optical Society of Korea
    • /
    • 제20권6호
    • /
    • pp.716-721
    • /
    • 2016
  • A single-and dual-wavelength switchable polarized Yb-doped double-clad fiber laser around 1120 nm based on a pair of fiber Bragg gratings (FBGs) is demonstrated. The polarization-maintaining (PM) linear cavity is composed of a double clad PM Yb-doped fiber (YDF) and a pair of PM FBGs. The laser can operate in stable dual-wavelength or wavelength-switching modes due to the polarization hole burning (PHB) and the spatial hole burning (SHB) enhanced by the PM linear cavity. In dual-wavelength operation, the two orthogonally polarized wavelengths are centered at 1118.912 nm and 1119.152 nm, with an interval of 0.24 nm and a signal to noise ratio (SNR) of 35 dB. The maximum output power is 14.67 W when the launched LD pump is 24 W corresponding to an optical efficiency of 61.1%. The lasing lines switchover may be realized by adjusting the polarization controller (PC) fitted in the cavity. The two single-wavelengths are 1118.912 nm and 1119.152 nm. When the injected LD pump is 24 W, the highest output powers are 7.68 W and 8.64 W corresponding to optical efficiencies of 32% and 36% respectively. The spectral linewidth of the lasing lines are 0.075 nm and 0.07 nm, and the average numerical values of PER aredB and 19.9 dB, respectively.

병렬 SOA 구조의 파장가변 레이저를 이용한 단면 영상획득 (Acquirement of cross-sectional image by using wavelength swept laser within the two SOAs parallel configuration)

  • 김훈섭;엄진섭
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.239-244
    • /
    • 2008
  • We have realized the swept source optical coherence tomography(SS-OCT) by using the self-fabricated wavelength swept laser(wavelength tuning range : 80nm, line-width : 0.12nm, wavelength sweeping rate : 50Hz). In addition, we have used the dual balanced detector that could make a mirror image in OCT display suppressed. We can also fabricate the comb filter of Michelson interferometer type for fast-signal processing in OCT. Using this SS-OCT system for measuring an mirror, a 1mm-depth glass and an onion, we confirmed that the in vivo epidermal cross-sectional images for them can be obtained appropriately.

  • PDF

수술용 2파장 펄스형 Nd:YAG 레이저 개발 (Development of Surgical Two-wavelegth Nd:YAG Laser)

  • 윤길원;김홍식
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권4호
    • /
    • pp.491-498
    • /
    • 1996
  • The development of a compact two-wavelength Nd:YAG laser for dental and ENT applications is presented. The Nd:YAG resonator generates either 1.06$\mu$m or 1.32$\mu$m. The wavelength selection is made at the control panel. The Nd:YAG laser parameters at 1.06$\mu$m are ; the maximum pulse duration of 150$\mu$s, repetition rates of I-100Hz, and the maximum average power of 25W. At 1.32$\mu$m, the pulse duration is the same where the repetition rates and the maximum average power are I-30Hz and lOW respectively. High voltage power supply consists of a simmer module and two identical high voltage DC converters. In order to make a complete medical laser system, an optical fiber delivery unit, foot pedal and water spray handpiece are also developed. The wavelength selection is reliable since no movement of optical or mechanical components is required. The high voltage power supply is compact, easy to be maintained and applicable for other laser systems due to its modular design.

  • PDF

복굴절이 큰 광섬유에 형성된 장주기 광섬유 격자를 이용한 파장 스위칭 가능한 광섬유 고리형 레이저 (Wavelength-Switchable Fiber Ring Laser Employing a Long-Period Fiber Grating Inscribed on a High Birefringent Fiber)

  • 이용욱
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1995-1997
    • /
    • 2007
  • In this paper we propose a wavelength-switchable fiber ring laser that employs a polarization-dependent fiber band stop filter. The fiber filter was fabricated by inscribing a long-period fiber grating on a high birefringent fiber. Dual-wavelength switching operation was accomplished by controlling the rotatable linear polarizer which rotated the polarization plane of the light circulating through the fiber laser cavity. The amplitude variation of both laser lines was measured to be less than 0.5 dB and the signal-to-amplified spontaneous emission ratio was more than 55 dB.

Sequential Delivery of Neodymium:Yttrium-Aluminum-Garnet and Alexandrite Laser Pulses for Treating Light Brown Seborrheic Keratoses

  • Cho, Sung Bin;Oh, Doojin;Yoo, Kwang Ho
    • Medical Lasers
    • /
    • 제8권1호
    • /
    • pp.24-27
    • /
    • 2019
  • Seborrheic keratoses (SKs) have been treated with non-ablative longpulsed (LP) lasers, including LP 532-nm neodymium (Nd): yttrium aluminum garnet (YAG), LP 695-nm ruby, LP 755-nm alexandrite (Alex), and LP 1,064-nm Nd:YAG lasers, with a pulse durations of 1-300 msec. Dual-wavelength LP 755-nm Alex/1,064-nm Nd:YAG laser systems have been used to remove hair follicles and treat various vascular and pigmented disorders by sequentially delivering two pulses of different wavelengths with interpulse intervals in the millisecond range. This paper reports the case of a female patient with multiple, discrete, light brown SKs on the dorsum of both hands that were treated effectively with one session of dual-wavelength LP 1,064-nm Nd:YAG/755-nm Alex laser treatment. The treatment settings for the LP Nd:YAG laser were comprised of a wavelength of 1,064 nm, fluence of 50 J/cm2, pulse duration of 5 msec, and beam size of 3 mm. The settings for the LP Alex laser were comprised of a wavelength of 755 nm, fluence of 50 J/cm2, pulse duration of 5 msec, and beam size of 3 mm. A hybrid mode was used to automatically deliver LP Nd:YAG and LP Alex laser pulses in succession at interpulse intervals of 20 msec. Six weeks after treatment, the patient exhibited remarkable improvement of the light brown seborrheic keratoses and was satisfied with the results.