• 제목/요약/키워드: Dual source

검색결과 384건 처리시간 0.03초

공기, 지열 및 복합 열원 열펌프의 중간기 에너지 소비량에 관한 연구 (Study on Energy Consumption of Air-source, Ground-source and Dual-source Heat Pump during Intermediate Season)

  • 조영욱;우태호;정광섭;김영일
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권4호
    • /
    • pp.1-7
    • /
    • 2013
  • This study is to compare energy consumption of air-source, ground-source and dual-source heat pump systems during intermediate season using dynamic simulation. Ground-source heat pump has higher COP than that of air-source but requires additional power consumption of auxiliary equipment such as circulation pump. During intermediate season when the outdoor air temperature is favorable, total COP of air-source heat pump may be greater than that of ground-source when circulation pump power consumption is included. Dual-source heat pump which selects the more favorable heat source is compared with air-source only and ground-source only heat pumps for total power consumption. Results show that power consumption of dual-source heat pump is lower than that of ground-source only by 0.73%.

뇌혈관조영검사 시 단일에너지 CT와 이중에너지 CT의 비교평가 : 화질 및 유효선량평가 (Comparative Evaluation of Single-Energy CT and Dual-Energy CT in Brain Angiography : Using a Rando Phantom and OSLD)

  • 신병근;안성민
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.809-817
    • /
    • 2023
  • 뇌출혈 진단 방법 중 CT는 비침습적으로 피사체의 3차원 영상을 제공할 수 있다. 그래서 응급실에서 급성인 환자 상대로 많이 사용되고 중요한 역할을 담당하고 있다. 뇌혈관 CT는 다른 혈관 CT에 비해 비교적 촬영 빈도가 높으며 뇌혈관 CT 검사 시 적절한 SNR, 합리적인 유효선량으로 검사를 해야한다. 뇌혈관 CT 검사 시 이중에너지와 단일에너지를 이용하였을 때 실질적으로 어느 것이 유효선량이 적으며, SNR이 차이가 없는지 환자영상과 Phantom영상을 같이 비교하였다. SNR과 CNR의 P값이 0.05이상일 때 통계적으로 차이가 없다고 보았고, 유효선량은 0.05미만일 경우 통계적으로 차이가 있다고 보았다. 실험에서는 병원영상의 환자선량을 비교하였을 때 이중에너지의 유효선량이 53.53% 적게, Phantom의 OLSD 이중에너지 유효선량이 57.94% 적게, Phantom의 Dose Report의 이중에너지 유효선량이 56.04% 적었다. 그래서 뇌혈관조영 CT는 이중에너지를 권장한다.

SUDS증발기를 사용한 2중열원 열펌프의 성능해석 (Performance analysis of dual source heat pump system with single unit dual source evaporator)

  • 우정선;이세균;이재효;박효순
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.391-400
    • /
    • 1999
  • The efficiency and capacity of an air source heat pump system decrease as the ambient temperature drops. One strategy of avoiding the decrease of the efficiency and capacity in air source heat pump system is to switch to another thermal energy source. Water can be a good candidate for the heat source. This paper presents the results of the performance analysis of heat pump system with a single unit dual source(SUDS) evaporator The heat exchanger combines two separated evaporators into a single evaporator and the object of the SUDS evaporator is to recover energy from dual heat sources, i.e. air and water. Simulation program is developed for the dual source heat pump system with a SUDS evaporator and experimental data are obtained and compared with the simulation results. Differences in heating capacity and COP are 7% and 8% respectively. Simulation results are in good agreement with the test results. Therefore, the developed program is effectively used for the design and performance prediction of the dual source heat pump system with a SUDS evaporator.

  • PDF

In-line Dual-Mode DBR Laser Diode for Terahertz Wave Source

  • Chung, Youngchul
    • Current Optics and Photonics
    • /
    • 제4권6호
    • /
    • pp.461-465
    • /
    • 2020
  • A dual-mode laser terahertz source consisting of two in-line distributed Bragg reflector (DBR) laser diodes (LD) is proposed. It is less susceptible to residual reflections from facets than an in-line dual-mode distributed feedback (DFB) LD. The characteristics of the proposed terahertz source are theoretically investigated using a split-step time-domain simulation. It is shown that terahertz waves of frequencies from 385 GHz to 1725 GHz can be generated by appropriate thermal tuning of two DBR LDs. The dual-mode DBR LD terahertz source exhibits good spectral quality for residual facet reflectivity below 0.02, but facet reflectivity of the in-line dual-mode DFB LD terahertz source should be below 0.002 to provide similar spectral quality.

단일 선원 장치와 이중 선원 장치 비교를 이용한 전산화단층촬영 금속인공물 감소에 대한 연구: 동물팬텀 제작을 이용한 실측적인 비교 (A Study of the CT MAR using Single-Source and Dual-Source Devices: Practical Comparison using Animal Phantom Fabrication)

  • 구은회
    • 한국방사선학회논문지
    • /
    • 제14권7호
    • /
    • pp.1003-1011
    • /
    • 2020
  • 본 연구는 듀얼 에너지 CT를 사용하여 금속인공물을 감소시키는 기법을 적용함에 있어 단일 선원과 이중 선원간의 영상 차이를 비교 평가하고자 한다. 단일 선원 장치로는 Discovery CT 256(GE, USA), 이중 선원 장치로는 Somatom Definition Flash(Siemens Health Care, Forchheim, Germany)를 이용하였다. 자체 제작한 팬텀(의료용 Titanium Screw를 삽입한 돼지다리)을 이중에너지 CT를 이용하여 동일 조건하에 선량을 변화시키며 영상을 얻은 후 정량적, 정성적 평가 하였다. 평가 방법으로는 뼈 주변, 조직 주변으로 나누고 금속삽입물로 인해 발생한 금속인공물(선속경화, 산란, 줄무늬)에 대하여 SNR을 측정하여 비교 분석하였다. 단일 선원 장치와 이중 선원 장치 간 금속 인공물 감소기법에는 영상의 차이가 있었다. 단일 선원 장치에서는 금속삽입물에 의한 선속경화 인공물이 이중 선원 장치에서 얻은 영상보다 많은 감소를 보이며 인공물의 방해 없이 주변 조직부가 잘 관찰 되었다. 이중 선원 장치에서는 금속삽입물에 의한 산란과 줄무늬 인공물이 단일 선원 장치에서 보다 많은 감소를 보이며 금속삽입물을 둘러싼 인접 조직들의 신호가 감소 없이 잘 관찰 되었다. 환자를 검사 시 보고자 하는 부위가 금속삽입물에 인접한 주변 조직이냐, 금속삽입물을 감싸는 전체적 조직이냐에 따라 단일 선원 장치와 이중 선원 장치를 구분하여 검사가 행해진다면 진단적으로 도움이 되는 영상을 획득할 수 있을 것으로 생각된다.

공기열원 2중히트싱크 열펌프의 성능해석 (Performance Analysis of Heat Pump System with Air Source Evaporator and Single Unit Dual Sink Condenser)

  • 우정선;이세균;이재효;박효순
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.11-22
    • /
    • 1998
  • Floor panel heating system using hot water is the primary heating system of domestic residential building. This paper presents the results of performance analysis of the heat pump system with air source evaporator and single unit dual sink(SUDSk) condenser. The heat exchanger combines two separated condensers into a single condenser and the object of the SUDSk condenser is to release energy to dual sinks, i.e. air for air heating system and water for panel heating system in one single unit. Simulation program is developed for single unit dual source(SUDS) SUDSk heat pump system and some experimental data are obtained and compared with simulation results. Differences of heating capacity and COP in dual source operating mode are 7% and 8% respectively. Simulation results are in good agreement with test results. Therefore, developed program is effectively used for design and performance prediction of dual source dual sink heat pump system with SUDS evaporator and SUDSk condenser.

  • PDF

이중 열원 히트펌프 시스템의 난방 성능과 운전 특성 (Heating Performance of Heat Pump System Using Dual Heat Source and Its Operation Characteristics)

  • 임효재;손병후
    • 한국지열·수열에너지학회논문집
    • /
    • 제17권2호
    • /
    • pp.30-41
    • /
    • 2021
  • This paper presents the heating performance analysis results of a heat pump system using a dual heat source. In this paper, a dual heat source refers to the ground-coupled heat exchanger using both a surface water heat exchanger (SWHE) and a vertical ground heat exchanger (VGHE). In order to evaluate the system performance, we installed a monitoring system to measure the temperature and power consumption of a heat pump and then collected operation data with 4 different load burdened ratios of the dual heat source heat exchanger. During the whole measurement period, the average heating capacity of a water-to-water heat pump unit was 37.3 kW. In addition, the compressor of the heat pump consumed 9.4 kW of power, while the circulating pump of the dual heat source heat exchanger used 6.7 kW of power. Therefore the average heating coefficient of performance (COP) for the heat pump unit was 4.0, while the entire system including the circulating pump was 2.7. Finally, the parallel use of SWHE and VGHE was beneficial to the system performance; however, further researches are needed to optimize the design data for various load ratios of the dual heat source heat exchanger.

복합 열원 공조시스템의 최적 제어 알고리즘 (Optimal Control Algorithm for the Dual Source Chiller Air Conditioning System)

  • 한도영;김진
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.881-888
    • /
    • 2004
  • Control algorithms for a dual source chiller air conditioning system were developed. These are control algorithms for the supply air temperature control, the supply header chilled water temperature control, the chiller chilled water temperature control, and the cooling tower water temperature control. These algorithms were analyzed by using a dynamic simulation program. Simulation results showed the energy savings and the satisfactory controls of an absorption and centrifugal chiller air conditioning system. Therefore, control algorithms developed for this study may effectively be used for the improved controls of the dual source chiller air conditioning system.

Rayleigh Fading AWGN채널에 대한 Dual-K길쌈부호의 평균자승오차 (MSE of Dual-k Convolutional Codes for an AWGN Channel with Rayleigh Fading)

  • 문상재
    • 한국통신학회:학술대회논문집
    • /
    • 한국통신학회 1986년도 춘계학술발표회 논문집
    • /
    • pp.1-3
    • /
    • 1986
  • We are concerned with transmitting numerical source data of {0, 1, 2, ..., 2k-1} through a channel coding system. The rate 1/v dual-k convolutional code with the orthogonal MFSK modulation and the Viterbl decoding is employed for the implementation of the channel coding system. The mean square error of the dual-k convolutional code is evaluated for the numerical source transmitted over an additive white Gaussian noise channel with Rayleigh fading.

  • PDF

Improved Dual-Path Energy Recovery Circuit using a Current Source and a Voltage Source for High Resolution and Large-Sized Plasma Display Panel

  • Yi, Kang-Hyun;Moon, Gun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.544-546
    • /
    • 2008
  • An improved dual-path energy recovery circuit (ERC) using a current source and a voltage source for plasma display panel (PDP) is proposed. The proposed ERC uses the voltage source to charge a panel and the current source to discharge the panel. Thus, the proposed circuit can make the panel charge to $V_S$ and discharge to 0V, fully and it is possible to achieve zero voltage switching (ZVS) of all switches in H-bridge inverter and zero current switching (ZCS) of all switches in the ERC. Moreover, it has less conduction and switching loss in ERC devices by the dual energy recovery paths for charging and discharging the panel. Furthermore, it has features of canceling the gas discharge current, high performance and the low cost ERC components. The operation principle and features of the proposed ERC are presented in detail and verified with 42-inch SD PDP.

  • PDF