• Title/Summary/Keyword: Dual scan

Search Result 101, Processing Time 0.029 seconds

Fabrication of Part and Its Evaluation Using Dual Laser in Solid Freeform Fabrication System (SFFS에서 듀얼 레이저를 이용한 부품 제작 및 평가)

  • Choi Jae-Won;Kim Dong-Soo;Doh Yang-Hoe;Lee Seok-Hee;Choi Kyung-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.3 s.246
    • /
    • pp.334-341
    • /
    • 2006
  • A solid freeform fabrication (SFF) system using selective laser sintering (SLS) is currently recognized as a leading process and the SLS extends the applications to machinery and automobiles due to various employing materials. In order to fabricate a large part with SFF system, dual laser approach has been introduced. Since the building room is divided into two regions, each scan path for dual laser system is generated based on the single laser scan path. Scan paths for each laser have to be synchronized and consider mechanical strength against fracture at the interfaced region. This paper will address generation of single laser scan path which deals with special cases for unnecessary scan points and generation of dual laser scan path according to various divided regions to enhance mechanical strength. To evaluate the developed scan path method, the specimen will be fabricated and evaluated.

Usefulness of Scan Position Change on Dual Time Point PET-CT in Pancreas Cancer (췌장암 Dual Time Point PET/CT 검사에서 Scan Position Change의 유용성 평가)

  • Chang, Boseok;Kim, Jae Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.5
    • /
    • pp.299-305
    • /
    • 2016
  • Despite of the development of medical equipments and technology. Pancreatic cancer has maked high false positive rate and low survival rate compared to other cancers. Therefore, early catch of pancreatic cancer is the only way to enhance the viability. It is important to find the exact location of the pancreas cancer in early stage. The method of optimum scan for early detection of pancreatic cancer on PET/CT exam is proposed. Examined the anatomical region that potentially can be missing from the supine position of ordinary pet/ct exam. The characteristics and usefulness of angle variation ($0^{\circ}$, $30^{\circ}$, $45^{\circ}$, $60^{\circ}$, $90^{\circ}$) of patients scan position is analyzed. The proposed scan method (named JJ-projection) is bringing advantage of anatomical discrimination by separating stomach, liver, gallbladder duodenum and pancreas. ROC curve analysis is shows to advantage of the JJ-Projection method. The sensitivity has increased 4.6% than the supine delay scan method, the results sensitivity has increased from 91% to 95.2%. The specificity has increased from 75.1% to 84%. Compared with the results observed in cancer by biological biopsy, The accuracy has increased from 86.8% to 94.1%.

Analysis of Laser Heat Distribution in Al-Cu Welding (알루미늄 구리 용접에서 레이저 열원 분포 분석)

  • Choi, Hae Woon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.1-7
    • /
    • 2021
  • A computer simulation was performed to study the effectiveness of temperature on the type of laser heat source in the context of the heterogeneous welding of aluminum and copper materials. Three different types of heat sources were used in the computer simulation: 1) Single Beam Straight Scan, 2) Single Beam Wobble Scan, and 3) Dual Beam Straight Scan. Among these sources, dual beam straight scan was found to be the most effective from the viewpoint of heat source control. Because the difference between the melting temperatures of copper and aluminum is approximately 400℃, a clear separation of heating temperature was required, and the dual beam straight scan provided superior controllability in this regard. When using the dual beam, the temperature of the 90:10 split was considerably easier to control than that of the 50:50 split. The optimal offset was calculated to be 4 mm off to the copper side, where the melting temperature and thermal conductivity were higher. In this manner, computer simulation was effectively used for determining the optimal laser beam hear source control without performing an actual laser welding experiment.

Dual Select Diode AMLCDs;A Path Towards Scalable Two Mask Array Designs

  • Boer, Willem Den;Smith, G. Scott
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.383-388
    • /
    • 2004
  • In this paper an alternative Active Matrix LCD technology is described with scalable, low cost processing. The Dual Select Diode AMLCD requires 60% lower capital investment in the array process than a-Si TFT arrays and results in 20% lower cost LCD modules. Development at several AMLCD manufacturers is in progress.

  • PDF

Recent Progress in Low Cost Dual-Select-Diode AMLCD Technology

  • Boer, Willem Den;Smith, G. Scott
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.873-877
    • /
    • 2005
  • Recent developments in Dual Select Diode (DSD) AMLCD technology are described. They include a novel array design and drive method with shared select lines, which leads to higher aperture ratio and a further reduction of module cost. A Color-On-Array DSD process and pixel layout compatible with In-Plane-Switching is also proposed.

  • PDF

Dual Lingual Thyroid Mimicking Mono-ectopic Thyroid in the Anterior View of Tc-99m Sodium Pertechnetate Thyroid Scan (전면 영상에서 하나로 오인된 두개의 설갑상전종)

  • Chong, A-Ri;Jeong, Shin-Young;Kwon, Seong-Young;Seo, Young-Soon;Ha, Jung-Min;Oh, Jong-Ryool;Bom, Hee-Seung;Song, Ho-Chun;Min, Jung-Joon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.485-487
    • /
    • 2008
  • Ectopic thyroid is not common disease and double ectopic thyroid is rare. Until January of 2008, dual ectopic thyroid has been reported only 23 cases in international literatures. Tc-99m sodium pertechnetate scan is playing an important role in the diagnosis of ectopic thyroid. In most of the cases, dual lingual thyroid tissues could be detected as two radiotracer uptake foci. We report a case of dual lingual thyroid mimicking mono-lingual thyroid in the anterior view of thyroid scan. Lateral view helped in this case to detect the dual lingual thyroid. With lateral view, the anatomical position and relationship could be examined in more detail.

Transition of Natural Convective Flows in a Horizontal Cylindrical Annulus: Pr=0.2 (수평 원주형 환형 내에서의 자연 대류 유동의 천이: Pr=0.2)

  • Yu, Ju-Sik;Ha, Dae-Hong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.804-810
    • /
    • 2001
  • Transition of flows in natural convection in a horizontal cylindrical annulus is investigated for the fluid with Pr=0.2. The unsteady streamfunction-vorticity equation is solved with finite difference method. As Rayleigh number is increased, the steady crescent-shaped eddy flow bifurcates to a time-periodic flow with like-rotating eddies. After the first Hopf bifurcation, however, a reverse transition from oscillatory to a steady flow occurs by the flow pattern variation. Hysteresis phenomenon occurs between the solution branches of up-scan and down-scan stages, and dual solutions with one steady and one oscillatory flow are found. Overall Nusselt of the flows at the flows at the down-scan stage is greater than that at the up-scan stage.

Optimal Scan time Analysis for Pancreatic Cancer Distinction in Dual time PET-CT Exam (이중시간 PET/CT 검사에서 췌장암 판별을 위한 최적의 Scan time 분석)

  • Chang, Boseok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.305-311
    • /
    • 2019
  • In this study, present the most useful delay scan time by statistical analysis of SUVm data for 30 suspected pancreatic cancer patients. Two statistical analysis and a mathematical model was applied to the theoretical formula by glucose and insulin mechanics, and a mathematical model was created. Statistical analysis was performed via Metlab p/g. Optimal delay scan time was suggested by Metlab p/g for the change of SUV value over time.In this study, for diagnosis pancreatic cancer by dual time point PET/CT, propose optimal delay scan time 131.5 minuts. The proposed delay scan time showed statistical reliability applicable to the diagnosis of pancreatic cancer (p<0.05). Delayed scanning with the suggested delay scan time of 131.5 minutes is considered to be useful for the diagnosis of pancreatic cancer compared to general PET / CT scan.hen the delayed test is performed with the proposed delay scan time 131.5 minuts, Compared with general PET/CT scans.

Investigation of the Effect of kV Combinations on Image Quality for Virtual Monochromatic Imaging Using Dual-Energy CT: A Phantom Study

  • Jeon, Pil-Hyun;Chung, Heejun;Kim, Daehong
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Background: In this study, we investigate the image quality of virtual monochromatic images synthesized from dual-energy computed tomography (DECT) at voltages of 80/140 kV and 100/140 kV. Materials and Methods: Virtual monochromatic images of a phantom are synthesized from DECT scans from 40 to 70 keV in steps of 1 keV under the two combinations of tube voltages. The dose allocation of dual-energy (DE) scan is 50% for both low- and high-energy tubes. The virtual monochromatic images are compared to single-energy (SE) images at the same radiation dose. In the DE images, noise is reduced using the 100/140 kV scan at the optimal monochromatic energy. Virtual monochromatic images are reconstructed from 40 to 70 keV in 1-keV increments and analyzed using two quality indexes: noise and contrast-to-noise ratio (CNR). Results and Discussion: The DE scan mode with the 100/140 kV protocol achieved a better maximum CNR compared to the 80/140 kV protocol for various materials, except for adipose and brain. Image noise is reduced with the 100/140 kV protocol. The CNR values of DE with the 100/140 kV protocol is similar to or higher than that of SE at 120 kV at the same radiation dose. Furthermore, the maximum CNR with the 100/140 kV protocol is similar to or higher than that of the SE scan at 120 kV. Conclusion: It was found that the CNR achieved with the 100/140 kV protocol was better than that with the 80/140 kV protocol at optimal monochromatic energies. Virtual monochromatic imaging using the 100/140 kV protocol could be considered for application in breast, brain, lung, liver, and bone CT in accordance with the CNR results.