• Title/Summary/Keyword: Dual energy absorptiometry

검색결과 236건 처리시간 0.019초

Feasibility study of SiPM based scintillation detector for dual-energy X-ray absorptiometry

  • Park, Chanwoo;Song, Hankyeol;Joung, Jinhun;Kim, Yongkwon;Kim, Kyu Bom;Chung, Yong Hyun
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2346-2352
    • /
    • 2020
  • Dual-energy x-ray absorptiometry (DXA) is the noninvasive method to diagnose osteoporosis disease characterized by low bone mass and deterioration of bone tissue. Many global companies and research groups have developed the various DXA detectors using a direct photon-counting detector such as a cadmium zinc telluride (CZT) sensor. However, this approach using CZT sensor has some drawback such as the limitation of scalability by high cost and the loss of efficiency due to the requirement of a thin detector. In this study, a SiPM based DXA system was developed and its performance evaluated experimentally. The DXA detector was composed of a SiPM sensor coupled with a single LYSO scintillation crystal (3 × 3 × 2 ㎣). The prototype DXA detector was mounted on the dedicated front-end circuit consisting of a voltage-sensitive preamplifier, pulse shaping amplifier and constant fraction discriminator (CFD) circuit. The SiPM based DXA detector showed the 34% (at 59 keV) energy resolution with good BMD accuracy. The proposed SiPM based DXA detector showed the performance comparable to the conventional DXA detector based on CZT.

Pediatric dual-energy X-ray absorptiometry: interpretation and clinical and research application

  • Lim, Jung Sub
    • Clinical and Experimental Pediatrics
    • /
    • 제53권3호
    • /
    • pp.286-293
    • /
    • 2010
  • Peak bone mass is established predominately during childhood and adolescence. It is an important determinant of future resistance to osteoporosis and fractures to gain bone mass during growth. The issue of low bone density in children and adolescents has recently attracted much attention and the use of pediatric dual-energy X-ray absorptiometry (DXA) is increasing. The process of interpretation of pediatric DXA results is different from that of adults because normal bone mineral density (BMD) of children varies by age, body size, pubertal stage, skeletal maturation, sex, and ethnicity. Thus, an appropriate normal BMD Z-score reference value with Z-score should be used to detect and manage low BMD. Z-scores below -2.0 are generally considered a low BMD to pediatrician even though diagnoses of osteoporosis in children and adolescents are usually only made in the presence of at least one fragility fracture. This article will review the basic knowledge and practical guidelines on pediatric DXA based on the International Society for Clinical Densitometry (ISCD) Pediatric Official Positions. Also discussed are the characteristics of normal Korean children and adolescents with respect to BMD development. The objective of this review is to help pediatricians to understand when DXA will be useful and how to interpret pediatric DXA reports in the clinical practice for management of children with the potential to develop osteoporosis in adulthood.

이중 에너지 X선 흡수계측법을 이용하여 폐경기간에 따른 골밀도 변화의 상관관계 연구 (Correlations Between Bone Mineral Density Changes in Postmenopausal Women Using Dual Energy X-ray Absorptiometry)

  • 정승훈;이태희;김동우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권1호
    • /
    • pp.47-51
    • /
    • 2018
  • To evaluate the applicability of osteoporosis management by statistical analysis of the correlation between bone mineral density (BMD) changes after menopause by dividing the T-score of bone mineral density measured by dual energy X-ray absorptiometry do. Between January 1, 2016 and July 31, 2017, women who visited the medical center of W Medical Center were enrolled in this study. The postmenopausal period was divided into 5 groups, There were 18 patients within 5 years, 44 patients in 6~10 years, 134 patients in 11~15 years, 109 patients in 16~20 years and 21 patients in 21 years or older. And postmenopausal women. Bone mineral density (BMD) of the lumbar spine and femur was measured using a dual energy X-ray absorptiometry. The lowest value among lumbar spine 1, 2, 3 and 4 and the lowest value among the femoral neck, greater trochanter, total femur, and ward Values were measured. The statistical significance was analyzed by using bivariate correlation coefficient method and one - way ANOVA. In 326 patients who underwent BMD, the correlation between bone mineral density and postmenopausal BMD showed a negative correlation (-.159, p<.01) with BMD of femur and BMD of lumbar spine The correlation between the menopausal period and negative (-.208, p<.01) was shown. There was a significant difference (p<.012) between the postmenopausal femur bone density and the mean value of the lumbar spine BMD (p<.000). The relationship between bone mineral density (BMD) and postmenopausal women's postmenopausal status can be estimated by estimating the bone mineral density and using it as a basic data for osteoporosis management.

골다공증에 따른 치조골 방사선사진농도와 하악하연두께의 변화에 대한 연구 (An Experimental Study of Radiographic Density of Alveolar Bone and Cortical Thickness of Mandible by Osteoporosis)

  • 이병도
    • Imaging Science in Dentistry
    • /
    • 제30권4호
    • /
    • pp.235-242
    • /
    • 2000
  • Purpose: To evaluate the effect of the systemic osteoporosis on radiographic density of alveolar bone and cortical thickness of mandible. Materials and Methods: The bone mineral density values of lumbar and femur were measured by dual-energy X-ray absorptiometry and T scores of lumbar, femur were obtained respectively. Radiographic densities of alveolar bones and panorama mandibular index (PMI, represents as cortical thickness) were analysed statistically according to age and T score variables. Results: The radiographic density of alveolar bone of maxillary molar showed significant difference by age and femur T group. That of mandibular molar showed significant difference between femur T group. Panorama mandibular index showed significant difference between age groups. Conclusion: The radiographic density of alvealar bones was more dependent on age and femur T than lumbar T. Cortical thickness of mandible was correlated with increasing age.

  • PDF

이중에너지 엑스선 흡광분석법을 이용한 골밀도검사의 관리법 (Management Methods of Bone Mineral Density Examination Using Dual Energy X-ray Absorptiometry)

  • 김호성;김태형;김상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.351-360
    • /
    • 2018
  • In recent years, demand for examination of bone mineral density (BMD) is increasing in Korea according aging society. Therefore, it is required to develop an efficient management program that can increase the safety and reliability of Dual Energy X-ray Absorptiometry (DXA) that can be applied to the criteria of the World Health Organization. It is necessary to develop a management program that can design a program to improve the accuracy and precision of the results of the analysis and to improve the accuracy of diagnosis of osteoporosis by development a high quality DXA report. It is recommended to prepare the examination manuals and to establish procedures of standard operating including the program to prevent the pitfalls during the examination, the compatibility evaluation of the examination data, and the contents of the radiation safety. In addition, relevant regulations on the production of high-quality DXA reports are required and government and related agencies should introduce individual and facility recognition programs through DXA measurement and education programs and training. It is considered that efforts should be made to prepare high quality DXA report by guidelines on all aspects of BMD for preparation about aging society.

이중에너지 방사선흡수 골밀도 장치의 품질관리 현황 (A Status Report on Dual Energy X-ray Absorptiometry Quality Control in Korea)

  • 김정수;노영훈;이인주;김성수;김경아;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권4호
    • /
    • pp.527-534
    • /
    • 2016
  • DEXA는 골다공증 진단에 가장 많이 사용되는 표준 측정법이다. 현재 국내에서 운영되고 있는 DEXA 장치는 5,671대이다. 본 연구에서는 국내에서 설치 운영되고 있는 DEXA장비의 품질관리 실태를 조사하였다. 3,000개 기관을 대상으로 한 설문 조사에서 12.6%의 응답을 받아 그 결과를 분석하였다. 결과에서 77.5%가 일일 품질관리를 시행하고 있으나 Shewhart chart는 68.5%, CUSUM chart는 86.0%가 모르거나 사용하지 않는다고 답하여 정확한 품질관리가 되지 않는 것으로 조사되었다. 정확한 골밀도 검사는 환자의 골절의 위험도를 산정하기 위한 자료로 활용된다. 하지만 부적절한 검사는 오진을 유발할 가능성을 높여준다. 따라서 정확한 골밀도 검사를 위해서는 적절한 보조기구를 사용하고 장치의 품질관리를 반드시 시행하여 장치와 자세에 대한 오차를 줄이고 검사 의료진의 교육을 통해 오류 요인을 줄이는 것이 필수적이다.

골밀도 장치의 교차분석 ; 국내 제조사와 해외 제조사 비교 (Cross Calibration of Dual Energy X-ray Absorptiometry Equipment for Diagnosis of Osteoporosis: between Domestic Manufacturers and Global Manufacturers)

  • 김정수
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.833-844
    • /
    • 2018
  • 골다공증의 진단에서 이중에너지 X선 흡수계수법은 가장 빈번하게 사용되는 검사이다. 외국의 골밀도 장치 제조사인 지이나 홀로직 장치에 대한 교차분석 연구는 다양하나 국내 제조사 이중에너지 X선 흡수골밀도 장치에 대한 비교 분석이 부족하다. 이에 본 연구에서는 국내 제조사의 이중에너지 X선 흡수골밀도 장치와 해외 제조사의 이중에너지 X선 흡수 골밀도 장치의 교차분석을 시행하여 교차식을 수립하였다. 유럽인 척추 팬텀을 이용한 검사에서 가장 높은 표준 편차를 보인 Dexxum T 장치의 경우 상. 중. 하부 척추에서0.030, 0.029, 0.037를 보였고, 홀로직의 Horizon Ci에서는 0.005와 0.004로 하부와 중간 척추에서 가장 낮은 표준편차를 나타냈다. 오스테오 프로맥스 장치의 경우 상부 척추에서 0.005의 표준편자를 나타냈다. 본 연구에서 도출한 국내 외 이중에너지 흡수 골밀도 장치의 교차식은 임상환경에서 골밀도 검사의 추척검사에 유용한 사례가 될 것이다. 또한 본 연구에서 제시한 국산 이중에너지 X선골밀도 장치에 대해 설정된 교차 방정식에 기초로 임상환경에서 보다 정확한 골밀도 추적 관찰을 위해 보다 다양한 국산 이중에너지 X선 골밀도 장치의 교차 보정을 설정하는 것이 필요하다.

대퇴골 경부 골절 환자에서 골다공증 평가를 위한 다중검출 CT의 이용: 이중에너지 X-선 흡수계측법과의 비교 (Multidetector Computed Tomography in Patients with Femoral Neck Fracture for Assessing Osteoporosis: Comparison with Dual Energy X-Ray Absorptiometry)

  • 이효정;황지영
    • 대한영상의학회지
    • /
    • 제82권1호
    • /
    • pp.173-181
    • /
    • 2021
  • 목적 대퇴골 경부 골절 환자를 대상으로 골다공증 평가를 위해 다중검출 전산화단층촬영(multidetector computed tomography; 이하 MDCT)에서의 감쇠 계수(Hounsfield unit; 이하 HU)와 이중 에너지 X선 흡수 계측법(dual energy X-ray absorptiometry; 이하 DXA)을 비교하였다. 대상과 방법 2016년 6월부터 12월까지 MDCT와 DXA를 모두 시행한 42명의 대퇴골 경부 골절 환자가 본 연구의 대상으로 포함되었다. MDCT에서는 정상 대퇴골 경부의 해면골에서 HU를 측정하였으며 DXA에서는 동 부위의 골밀도 및 T 값을 얻었다. HU와 골밀도 및 T 값의 상관관계를 Spearman 상관계수를 이용하여 분석하였다. 결과 대퇴골 경부 골절 환자의 골밀도와 T 값의 평균은 각각 0.650 g/cm2과 -2.4이었다. 정상, 골감소증, 골다공증 환자 군의 HU의 평균은 각각 131.9, 98.9, 41.3이었다. HU는 골밀도(r2 = 0.670; p < 0.001) 및 T 값(r2 = 0.676; p < 0.001) 모두와 양의 상관관계를 보였다. 결론 다중검출 전산화단층촬영에서 감쇠계수의 측정은 골다공증 선별검사를 위한 유용한 진단적 도구가 될 수 있다.

골밀도 측정의 올바른 임상 적용 (Clinical Application of Bone Mineral Density Measurement)

  • 김덕윤
    • 대한핵의학회지
    • /
    • 제38권4호
    • /
    • pp.275-281
    • /
    • 2004
  • Compared with the earlier technique of dual photon absorptiometry (DPA) using $^{153}Gd$ radionuclide source, dual energy X-ray absorptiometry (DXA) has advantages of higher precision, accuracy and shorter scanning time. Despite the change from DPA to DPX, the nuclear medicine physicians has remained one of major suplier of this service due to long-standing use of DPA. Among many kinds of bone densitometries, DXA is the "gold standard" for the noninvasive diagnosis of osteoporosis. Especially there is no role for peripheral devices in the monitoring of patients on therapy. But, there are some areas of controversy related to the application of DXA, such as proper site of measurement, accurate interpritation, appropriate use of T-score, and the reference population young database. And the accuracy, precision, and quality control issues relating to bone density measurement are important subjects. To address these issues, the International Society for Clinical Densitometry (ISCD) has convened two Position Development Conferences and addressed official positions. This review deals the key elements of ISCD position paper and other important issues on the management of bone densitometry.