• Title/Summary/Keyword: Dual chamber

Search Result 120, Processing Time 0.023 seconds

Design and Implementation of High Efficiency Slot Antenna for the Metal Notebook Dual Band WiFi MIMO System (메탈 노트북 Dual 밴드 WiFi MIMO용 고효율 슬롯안테나 설계 및 구현)

  • Yoo, Younghyeouk;Lee, Moonhee;Son, Taeho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1338-1343
    • /
    • 2018
  • MIMO(Multiple Input Multiple Output) slot antenna that operates on the dual WiFi band(2.401~2.495GHz, 5.18~5.825GHz), in this paper, was studied. The basic theory for the slot design is based on the coupling between adjacent slot, and slots are fed by the each microstrip lines. Two slot antennas for the MIMO operation are located on the left and the right side of top of the metal notebook, and grounds between a notebook and two microstrip feeding lines are connected. Measurement of return loss showed under -6dB on entire design band, and isolation was below than -30dB. Radiation efficiency, average gain and peak gain for the left and the right slot were measured in the anechoic chamber, and showed good performances as 57.25%, -2.42dBi, 5.64dBi and 55.35%, -2.61dBi, 6.42dBi for the 2.4GHz band and 55.89%, -2.58dBi, 7.3dBi and 53.79%, -2.8dBi, 7.54dBi for the 5GHz band.

Design and Implementation of Dual Band Modified Biconical Antenna for Wireless LAN

  • Oh Jong Dae;Son Ji Myoung;Yang Woon Geun
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.181-184
    • /
    • 2004
  • In this paper, we propose the dual band(2.4GHz and 5GHz) antenna for access point of WLAN(Wireless Local Area Network) which has similar radiation patterns for each band. Simulation results by using HFSS(High Frequency Structure Simulator) for the proposed antenna are presented. The electrical characteristics of the proposed antenna are measured with HP 8510C network analyzer and included. And radiation patterns are measured with rectangular anechoic far field antenna chamber. Measured results show that $S_{11}$ is less than - 14dB and VSWR(Voltage Standing Wave Ratio) is less than 1.5 for all frequency bands of interest. The measured maximum gain for elevation pattern at 2.40GHz is about 2.46dBi at $theta=-78^{\circ}$ and maximum gain for 5.825GHz is about 2.70dBi at $theta=-80^{\circ}.$ And the implemented antenna has good radiation pattern characteristic, therefore, we expect that the implemented dual band antenna is applicable for access point of WLAN.

  • PDF

A STUDY ON THE VOND STRENGTH OF PORCELAIN LAMINATE AND COMPOSITE RESIN CEMENTS (라미네이트 도재와 복합레진 시멘트의 결합강도에 관한 연구)

  • Kim, Sung-Il;Lim, Ho-Nam;Park, Nam-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.91-109
    • /
    • 1991
  • The purpose of this study were to comfirm the effects of the thickness and kinds of porcelain, etchants, illumination time, elapsed time for the measurement, and chemical cure component to the bond strength of porcelain laminate and composite resin cement, and to compare the effects between the light cured resin and the dual cured resins. The etched porcelain surface, the sectioned surface crossing porcelain and resin after bonding, and the debonded surfaces were observed by the SEM. One product of laminate porcelain powder, one light cured resin and two dual cured resins were selected. Each resin cements are lightened through the thin porcelain disc which was cut from cylindrical porcelain specimen by the diamond saw, and by the light through the porcelain disc they were bonded. Changes of thickness and kinds of porcelain, etchants, illumination time, and the elapsed time for the measurement were considered as variables for the bond strength. And the bond strength of porcelain and dual cured resins under the conditions of autopolymerization or the removal of chemical cure component were measured and compared. Bond strength were measured by shear stress. The etched surface, the cross-sectioned surface, and the debonded surface of porcelain or resin were observed by SEM. On the summary of this study, the following conclusions can be stated; 1. Bond strength of light cured resin was decreased inversely by the thickened porcelain laminate and showed the lowest value to the masking dentin porcelain among 4 kinds of porcelain powder. 2. Bond strength of autopolymerization of dual cured resin without illumination in dark chamber were from 75% to 98% to the data of dual cured resin with illumination. 3. Bond strength of dual cured resin used without chemical cured components were same to them of light cured resin. 4. Cross-sectioned surface treated by silane did not show the gap between the porcelain and resin. 5. Illumination over 80 seconds did not make the significant increase of bond strength on all kinds of resin.

  • PDF

Development of a multi-functional nano-fabrication system for fabrication and measurement (가공 및 측정이 가능한 복합나노가공시스템의 개발)

  • 장동영;박만진;김진현;한동철
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.466-471
    • /
    • 2004
  • In focused-ion-beam (FIB) application of micromachining and device transplantation, four kinds of FIB processes, namely FIB sputtering, FIB-induced etching, redeposition, and FIB-induced deposition, are well utilized. As with FIB systems, scanning electron microscopes(SEMs) were extensively used in the semiconductor industry. They are the tools of choice for defect review and providing the image resolution needed for process monitoring. The enhanced capabilities of a dual-column on one chamber system are quickly becoming realized by the nano industry for performing a wide range of application.

  • PDF

Optimal Design of Electromagnetic Type Active Control Engine Mount in Consideration of Actuator Efficiency (능동 및 수동 특성을 고려한 전자석 구동형 능동 엔진 마운트의 최적화)

  • Lee, Bo-Ha;Lee, Chong-Won
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1112-1118
    • /
    • 2007
  • This paper investigates the performance of an electromagnetic type active control engine mount (ACM) recently developed in the laboratory. The ACM employs the basic structure of the conventional hydraulic engine mount of which upper chamber is connected to a dual magnet electromagnetic actuator. The actuator, that essentially replaces the existing decoupler of the conventional passive hydraulic engine mount, actively controls the upper chamber pressure. Using the linearized ACM model incorporated with the actuator dynamics, we suggest an optimal design of ACM, maximizing the actuator efficiency as well as the vibration isolation efficiency.

  • PDF

Quantitative Vapor Phase Exciplex Fluorescence Measurements at High Ambient Temperature and Pressure

  • Kim, Tongwoo;Jaal B. Ghandhi
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.157-167
    • /
    • 2003
  • The exciplex fluorescence technique with the TMPD (tetamethyl-Ρ-phenylene-diamine) / naphthalene dopant system was applied in a combustion-type constant-volume spray chamber. A detailed set of calibration experiments has been performed in order to quantify the TMPD fluorescence signal. It has been demonstrated that the TMPD fluorescence intensity was directly proportional to concentration, was independent of the chamber pressure, and was not sensitive to quenching by either water vapor or carbon dioxide. Using a dual heated-jet experiment, the temperature dependence of TMPD fluorescence up to 1000 K was measured. The temperature field in the spray images was determined using a simple mixing model, and an iterative solution method was used to determine the concentration and temperature field including the additional effects of the laser sheet extinction. The integrated fuel vapor concentration compared favorably with the measured amount of injected fuel when all of the liquid fuel had evaporated.

The Pumping Characteristics of the Valveless Peristaltic Micropump by the Variation of Design Parameters

  • Chang, In-Bae;Park, Dae-Seob;Kim, Byeng-Hee;Kim, Heon-Young
    • KSTLE International Journal
    • /
    • v.3 no.2
    • /
    • pp.101-109
    • /
    • 2002
  • This paper presents the fabrication and performance inspection of a peristaltic micropump by flow simulation. The valve-less micropump using the diffuser/nozzle is consists of base plate, mid plate, top plate and connection tubes fur inlet and outlet. In detail, the base plate is composed of two diffuser nozzles and three chambers, the mid plate consists of a glass diaphragm for the volumetric change of the pumping chamber. The inlet and outlet tubes are connected at the top plate and the actuator fur pressing the diaphragm is located beneath the top plate. The micropump is fabricated on the silicon wafer by DRIE (Deep Reactive ion Etching) process. The pumping performances are tested by the pneumatic test rig and compared with the simulated results fur various dimensions of diffuser nozzles. The pumping characteristics of the micropump by the volumetric change at the pumping chamber is modeled and simulated by the commercial software of FLOW-3D. The simulated results shows that reverse flow is the inherent phenomena in the diffuser nozzle type micropump, but it can be reduced at the dual pumping chamber model.

A Study on the Performance Evaluation of Dual Swirl Injectors (Dual Swirl 인젝터의 성능 평가에 관한 연구)

  • 김선진;정해승
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.113-123
    • /
    • 2003
  • Both numerical analysis and experiment of cold and hot tests were performed to obtain basic design data for the swirl coaxial type Injector and to predict the combustion performance. Mass distribution, mixing distribution, mixing efficiency, characteristic velocity efficiency were measured by the cold tests and numerical analysis using the commercial thermo-hydraulic program. Test and analysis variables were recess, pressure drop, velocity ratio, mixing spray, mixture ratio. Hot tests were performed for the Uni-element injector to compare the performance with the cold test results, and, hot tests for Multi-element injector were performed to compare the performance with Uni-element injector. Designed thrust of the Uni-element injector liquid rocket was 35kgf at sea level and combustion chamber pressure, 20bar. Kerosene and Lox were used as a propellant.

Synthesis of Ceramic Protective Coatings for Chemical Plant Parts Operated in Hi-temperature and Corrosive/Erosive Environment

  • Son, M.C.;Park, J.R.;Hong, K.T.;Seok, H.K.
    • Corrosion Science and Technology
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2005
  • Some feasibility studies are conducted to produce an advanced ceramic coating, which reveals superior chemical and mechanical strength, on metal base structure used in chemical plant. This advanced coating on metallic frame can replace ceramic delivery pipe and reaction chamber used in chemical plant, which are operated in hi-temperature and corrosive/erosive environment. An dual spraying is adopted to reduce the residual stress in order to increase the coating thickness and the residual stress is estimated by in-situ manner. Then new methodology is tried to form special coating of yttrium aluminum garnet(YAG), which reveals hi-strength and low-creep rates at hi-temperature, superior anti-corrosion property, hi-stability against Alkali-Vapor corrosion, and so on, on iron base structure. To verify the formation of YAG during thermal spraying, XRD(X ray diffraction) technique was used.

Effects of Phase Difference between Voltage loaves Applied to Primary and Secondary Electrodes in Dual Radio Frequency Plasma Chamber

  • Kim, Heon-Chang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.2 s.11
    • /
    • pp.11-14
    • /
    • 2005
  • In plasma processing reactors, it is common practice to control plasma density and ion bombardment energy by manipulating excitation voltage and frequency. In this paper, a dually excited capacitively coupled rf plasma reactor is self-consistently simulated with a three moment model. Effects of phase differences between primary and secondary voltage waves, simultaneously modulated at various combinations of commensurate frequencies, on plasma properties are investigated. The simulation results show that plasma potential and density as well as primary self-dc bias are nearly unaffected by the phase lag between the primary and the secondary voltage waves. The results also show that, with the secondary frequency substantially lower than the primary frequency, secondary self·do bias remains constant regardless of the phase lag. As the secondary frequency approaches to the primary frequency, however, the secondary self-dc bias becomes greatly altered by the phase lag, and so does the ion bombardment energy at the secondary electrode. These results demonstrate that ion bombardment energy can be more carefully controlled through plasma simulation.

  • PDF