• 제목/요약/키워드: Duability

검색결과 5건 처리시간 0.021초

양이온 UV 금속인쇄의 경화 안정성 및 내구성 향상 연구 (A Study on the Improvement of Stubility and Duability for Cationic UV Curable Metal Printings)

  • 신종순;성기웅
    • 한국인쇄학회지
    • /
    • 제25권1호
    • /
    • pp.95-107
    • /
    • 2007
  • This study starts to find a way out, experiment and apply commercial UV coatings to the cap closures. The cap closures is made form coating and succeeding deformation process. It is coated with several printing layers, printing and over print varnish coating. Then it pressed in three steps of press called 'deep-drawing'. In this study, two kinds of coating was designed and accomplished in the base of the same manufacturing and environment conditions. Consequently, UV curable ink have adequate performance in this experiment (T-bending, Erichsen Test), but it were experienced several damages in this experiments (web-bending, impact test). They were not cured enough to endure the friction and a unique shape of serial cracks were appeared.

  • PDF

옥내용 뿜칠내화피복재의 촉진내구성 조건 설정 연구 (Development of Acceleration Duability test condition for Fireproof Spray-Application.)

  • 김대회;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.170-171
    • /
    • 2014
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. This study is covers standardization of the methods for assessing the durability of SFRM. In Korea, more than 90 percent of SFRM are used indoors. So This study is to decide proper test method through investigation and examination of effect factor to performance of fire-resistant structure and applicable test method.

  • PDF

옥내용 뿜칠내화피복재의 촉진내구성 조건 설정 연구(II) (Development of Acceleration Duability test condition for Fireproof Spray-Application(II).)

  • 김대회;이건철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 추계 학술논문 발표대회
    • /
    • pp.109-110
    • /
    • 2014
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. This study is covers standardization of the methods for assessing the durability of SFRM. In Korea, more than 90 percent of SFRM are used indoors. So This study is to decide proper test method through investigation and examination of effect factor to performance of fire-resistant structure and applicable test method.

  • PDF

옥내용 뿜칠내화피복재의 촉진내구성 시험방법 연구 (Development of Acceleration Duability Test Method for Fireproof Spray-Applocation)

  • 김대회;이건철;이세현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.104-105
    • /
    • 2013
  • The buildings constructed with steel structure is coated with certified fire resistive material to resist from fire. Coating materials lose their initial performances as time passes, so they need some maintenance. Fireproof spray-application also loses its performance and this performance loss of thr fireproof spray-application is very important because fire resistance of buildings depends on fireproof spray-application. So this study is to develop Acceleration durability test method of Fireproof spray-application, and use the Certification of fire resistant coating system.

  • PDF

전동 스쿠터 프레임의 구조 진동해석 연구 (Structure-Vibration Analysis of Electric Scooter Frame)

  • 천세영;성기원;박해이;김인수;강성기
    • 한국기계가공학회지
    • /
    • 제15권1호
    • /
    • pp.116-121
    • /
    • 2016
  • The purpose of this study was to ensure the safety of a scooter frame through a structure and vibration analysis according to the tube thickness and weight of the frame of the electric scooter, which is currently being commercialized. According to the results of this study, the largest displacement value of 0.13238mm appeared in the 3-mm thickness when applying the 100-kg load according to the thickness, and 0.026591mm and 0.019062mm appeared in the 4-mm and 5-mm thicknesses, respectively. The difference between the 4-mm and 5-mm values was 0.007529mm, and it showed low displacement. Thus, the frame of more than 4-mm thickness was considered safe. In addition, the experimental result for the natural frequency from Mode 1 to Mode 6 in the vibration analysis was within 601.88Hz. In the 5-mm frame, the durability regarding the vibration was recognized as the best due to the appearance of the critical frequency (341.03Hz).