• 제목/요약/키워드: Dryer performance evaluation

검색결과 15건 처리시간 0.022초

열화상카메라를 이용한 직물의 물 흡수 및 건조 특성에 대한 실험 연구 (Experimental Study on Water Absorption and Drying Characteristics of Various Fabrics using IR Camera)

  • 김정배
    • 한국분무공학회지
    • /
    • 제28권1호
    • /
    • pp.10-15
    • /
    • 2023
  • Recently, various types of towels and dishcloth dryer products are being widely distributed in Korea. Evaluation methods for water absorption properties of various fabrics have been developed, and there are many studies using them. This study newly intended that whether it is possible to obtain data that can quantitatively analyze the water absorption characteristics of various fabrics, to show the correlation between the water absorption height and the amount of water (water holdup) absorbed, and to experimentally suggest the applicability to evaluate the drying capacity of towel dryer using IR camera. Through these experiments, it was confirmed that quantitative data on the water absorption height of various fabrics can be measured using an IR camera and can be clearly applied to the performance evaluation of actual products.

저온진공건조 공정에 제습제 적용을 위한 타당성 연구 (Feasibility Study for Applying Desiccant to Low Temperature Vacuum Drying Process)

  • 심연호;강지수;변시예;장영수;강병하
    • 설비공학논문집
    • /
    • 제28권5호
    • /
    • pp.208-215
    • /
    • 2016
  • This study was conducted to improve the performance of low-temperature vacuum dryer by applying desiccant to cold trap. Performance evaluation was carried out using several desiccants. The amounts of absorption and diffusivity were measured based on analytic model. Results of desiccant performance evaluation revealed that silica-gel had the most excellent performance for conditions of low-temperature vacuum drying process. Silica-gel was applied to cold trap for evaluating the drying performance. The experiment results showed that the drying time was extended as the thickness of sample was increased due to increased heat and mass transfer resistance of drying sample. In addition, as heating plate temperature was increased, drying time was decreased due to increased evaporation pressure of drying sample. Furthermore, drying time with desiccant was decreased approximately 20% than that without desiccant.

열펌프를 이용한 벼의 저온건조성능평가 (Performance Evaluation of Rough Rice Low Temperature Drying Using Heat Pump)

  • 김훈;한재웅
    • 산업식품공학
    • /
    • 제13권4호
    • /
    • pp.308-313
    • /
    • 2009
  • 국내 벼 건조기간의 기상조건에 적합한 열펌프를 설계, 제작하여 기본 성능을 측정하고, 건조온도 20-50${^{\circ}C}$ 범위에서 벼 건조실험을 통하여 건조특성 및 소요에너지를 분석하였다. 열펌프는 건압축 냉동 사이클에서 냉동효과는 173.8 kJ/kg이었으며, 냉매순환량은 49.6 kg/hr이었다. 따라서, 성능계수는 5.5로 표준냉동사이클에서 냉매 R-22의 성능계수 4.0에 비해 높은 값을 나타내었으며, 목표 건조공기의 온도 30${^{\circ}C}$ 및 상대습도 40%에 도달하는 시간은 6분 및 7분으로 만족할 만한 수준이었다. 건조온도와 곡온과의 온도차이는 건조온도 21.9${^{\circ}C}$에서는 약 1.5${^{\circ}C}$, 건조온도 48.7${^{\circ}C}$에서는 약 8.5${^{\circ}C}$로서, 건조실에서 상승한 곡온은 템퍼링실에서 충분한 냉각이 이루어지는 것으로 판단되었다. 건조온도 21.9, 30.7 38.8 및 48.7${^{\circ}C}$에서 건조속도는 0.29, 0.61, 0.85 및 1.25%/hr로 나타나 상용건조기와 유사한 수준이었다. 건조온도 21.9${^{\circ}C}$에서 소요에너지는 325 kJ/kg, 건조온도 30.7, 38.8 및 48.7${^{\circ}C}$에서는 667, 692 및 776 kJ/kg로 나타나 외기조건에 따라 건조소요에너지의 차이가 발생했지만, 화석연료를 사용하는 상용 화력건조기의 벼 건조소요에너지 4,000-5,000 kJ/kg에 비해 평균 86% 절감되는 것으로 나타났다.

태양열 건조 시스템에 관한 실험적 연구(I) - 무우절편의 태양열 건조 특성 - (Experimental Studies for Solar Drying System of Agricultural Products(I) - Solar drying characteristics for radish -)

  • 고학균;김용현;송대빈;김만수
    • 태양에너지
    • /
    • 제11권3호
    • /
    • pp.9-20
    • /
    • 1991
  • 무우절편의 태양열건조 및 천일건조 실험을 수행하여 건조 특성 및 품질 변화 특성을 비교하여 분석하였다. 무우절편의 태양열 건조 시스템은 공기 가열식 태양열 집열기와 터널 건조실로 구성된다. 태양열 집열기의 구성 요소에 에너지 평형식을 적용하여 일사량과 송풍량의 변화에 따른 집열기의 집열성능을 분석할 수 있는 시뮬레이션 모형을 개발하였다.

  • PDF

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.