• 제목/요약/키워드: Dry wall

Search Result 314, Processing Time 0.026 seconds

Development of Dry Roof Construction Method Using Double Skin Roof System (이중 지붕 시스템을 활용한 건식 지붕 공법 개발)

  • Kim, Sung-Jin;Kim, Chung-Shik;Ryu, Han-Guk
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.256-257
    • /
    • 2013
  • Roof and exterior wall of general formal buildings are designed and constructed through design focused exterior wall system and drainage and waterproof roof system. However, there are no classification of exterior wall and roof in freeform buildings and they are integrated as a surface of freeform buildings. Therefore it is necessary to develop the dry roof construction method using double skin roof system satisfying the design and function of the envelope. In this study, we have an effort to develop construction method of double-skin roof system using metal panel and PV.

  • PDF

Seismic Performance Evaluation of Flat Column Dry Wall System and Wall Slab System Structures (무량복합 및 벽식 구조시스템의 내진성능평가)

  • Kang, Hyungoo;Lee, Minhee;Kim, Jinkoo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.3
    • /
    • pp.259-266
    • /
    • 2012
  • In this paper the seismic performance of a flat plate wall system structure was evaluated based on the ATC-63 approach, and the results were compared with those of a wall slab structure having the same size. As analysis model structures, a twelve story flat plate wall structure and a wall slab structure were designed based on the KBC-2009, and their seismic performances and collapse behaviors were evaluated by nonlinear static and incremental dynamic analyses(IDA). It was observed that the flat plate wall structure was designed with smaller amount of reinforced concrete, and showed slightly larger displacement response compared with those of the wall slab structure. The collapse margin ratios of the two structures obtained from the incremental dynamic analyses satisfied the limit states specified in the ATC-63, and the structures turned out to have enough capacity to resist the design level seismic load.

ADP DRY ETCHER TECHNOLOGY (ADP Dry Etcher 장비개발의 현황)

  • Kim, Jeong-Tae
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2008.05a
    • /
    • pp.23-29
    • /
    • 2008
  • - High Density Plasma Source-CCP-Dual/Triple, RF Frequency Control - Radical/Flux Analysis - Low Pressure Process - Chamber Design (Process gap/Wall gap) - Chamber Temp. Control. - ESC Dielectric Materials - Uniform Gas Injection

  • PDF

Phenomenological behavior of Bubbles and dry spots at CHF on a short heated wall: Pool boiling of R-113 (소형가열면에서 CHF 발생시 Bubble 및 Dry Spot의 현상학적 거동 R-113의 수조비등)

  • Chung, H.J.;Kim, B.D.;Chun, S.Y.;No, H.C.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.189-194
    • /
    • 2001
  • A simultaneous visualization of the behavior of bubbles and dry spots has been carried out for pool boiling of R-1l3 on a horizontal heater. From video imaging and image processing analysis, the formation of bubbles and dry spots occurs simultaneously, and therefore they should be considered as a synchronized concept rather than independent identities. The dry spot density is equivalent to the active site density in the region before CHF. At CHF point, large dry areas due to the coalescence of neighboring dry areas cover the heater surface.

  • PDF

Microstructure and Antioxidative Activity of Red, White and Extruded Ginseng

  • Ryu, Gi-Hyung
    • Preventive Nutrition and Food Science
    • /
    • v.11 no.1
    • /
    • pp.61-66
    • /
    • 2006
  • The objective of this study was to compare the color and microstructure of powder, redness, brownness, and antioxidative activity in extruded ginseng, white ginseng and red ginseng extracts. The colors of extruded dry ginseng powder (moisture content 30%, barrel temperature $110^{\circ}C$, and screw speed 200 rpm) were similar to those of red ginseng. Intact cell wall structure was examined in dried root ginseng at $70^{\circ}C$ (A), white ginseng with skin (D), white ginseng without skin (E), and red ginseng (F) under a scanning electron microscope. The cell wall was not detected in samples B and C (dry ginsengs extruded with 25% and 30% moisture contents, respectively). Intact starch granules were detected in samples A, D, and E under a scanning electron microscope. Melted starch granules were detected in samples B, C, and F. Colors (L, a, b) of 50% EtOH extracts were similar in samples C and F. Browniness and redness of extracts were high in extruded dry ginseng and red ginseng extracts. Extruded dry ginseng (B) showed higher electron donation ability and phenolic content than the other samples.

Studies on the Boron Metabolism of Orchid -Influences on the Cell Wall Structure and its Components- (양란의 붕소 대사에 관한 연구 -특히 세포벽 형성 및 분획 조성에 미치는 영향-)

  • 강영희
    • Journal of Plant Biology
    • /
    • v.22 no.1_2
    • /
    • pp.35-43
    • /
    • 1979
  • The present investigation has been made to study the deficiency symptoms of boron on the formation of cell wall and the development of the individual components of the orchid cell wall. Analytical samples were taken from two sources; one from the individual orchid plants started from an apical meristem culture followed by the generation of the protocorm-like body which was developed into a plant, the other from the plant cultivated in water for 30 days. The amount of boron in the cultrues were controlled and the deficiency symptoms were observed under theelectron microscope, optical microscope with samples taken from the zones of elongation of leaves and compared the dry weight of cell walls and finally the various fractions of the cell wall components. The following results were obtained: (1) The growth of roots and leaves was hampered in the boron deficient plants. (2) In the boron-deficient leaves a severe necrosis and cracks were developed in the tissue of zone of elongation besides the decrease in growth. (3) under the electorn microscope the cell walls of boron-deficient plants showed rough undulated structures unlike the smooth control cell walls. (4) the dry weight of total cells and cell walls of boron deficient plants were higher than the control plants. (5) In the boron deficient plant the amout of pectin and hemicellulose isolated from cell walls were higher and the amount of protein was lower than the controlled plots.

  • PDF

Flexural behavior of precast concrete wall - steel shoe composite assemblies with dry connection

  • Wu, Xiangguo;Xia, Xinlei;Kang, Thomas H.K.;Han, Jingcheng;Kim, Chang-Soo
    • Steel and Composite Structures
    • /
    • v.29 no.4
    • /
    • pp.545-555
    • /
    • 2018
  • This study aimed to investigate the flexural behavior of precast concrete (PC) wall - steel shoe composite assemblies with various dry connection details at mid-span. Flexural tests were performed for five scenarios. Test parameters included the width of test specimens, arrangement of steel shoe connectors, and use of structural adhesive or waterproof tape at the mid-span joint. The test results showed that the PC wall - steel shoe composite assemblies joined at mid-span showed flexural damage patterns combined with rotational deformation, and the structural performance was satisfactory regardless of the arrangement of steel shoe connectors. Considering the two deformation components (flexural deformation by bending and rotational deformation due to joint opening), a theoretical model was proposed to analyze flexural strength and joint opening, and the simple model gave good predictions with acceptable accuracy.

Dry Connections for Precast Shear Wall Systems (프리캐스트 전단벽 시스템의 건식접합부에 관한 연구)

  • Hong, Sung-Gul;Lim, Woo-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.530-533
    • /
    • 2006
  • This thesis investigates the behavior of precast wall systems with a new vertical connection which are proportioned by the displacement based design. The proposed precast wall systems are supposed to provide additional spaces and seismic strengthening in remodeling existing residential buildings. For a fast remodeling constructions using PC walls require an efficient, economic fabrication method. A C-type vertical connections for PC wall systems is proposed for transfer of bending moment between walls in the vertical direction while a shear key in the center of wall is prepared to transfer shear forces by bearing. The proposed vertical connection allows us easy fabrication because of different direction of slots at the edges of wall. The dimension of C-type connection components are determined by engineering models and a series of test.

  • PDF

Reinforced Earth Retaining Wall of The Collapsed-A Case Study. (보강토옹벽의 사고사례에 관한 연구)

  • Yoo, Chung-Sik;Jung, Hyuk-Sang;Lee, Soung-Woo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.958-967
    • /
    • 2004
  • This paper deal with cause and analysis about case of collapsed reinforced-soil retaining wall. The analysis of the cause was carried through experimentation, slop stability analysis and literature study. The experimentation treated the large direct shear test, the hydraulic conductivity test and the other basic test through backfill extracted from collapsed reinforced-soil retaining wall. The ultimate tensile strength was established by rib tensile strength test of geogrid. The analysis of internal and external stability of reinforced-soil retaining wall was performed on the basis of parameters. The result of analysis, reinforced-soil retaining wall and the slope at the dry season are stable. However, the factors that fine-grained soil at hydrometer test exceed the standard of the design, rainfall duration is too long at the time of collapse and monthly pricipitation is heavy are cause of the collapse.

  • PDF

Active Earth Pressure Acting on the Cylindrical Retaining Wall of a Shaft (원형수직구의 흙막이 벽체에 작용하는 주동토압)

  • Chun, Byungsik;Shin, Youngwan
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.4
    • /
    • pp.15-24
    • /
    • 2006
  • It is well known that earth pressure on the cylindrical open caisson and cylindrical retaining wall of a shaft is less than that at-rest and in plane strain condition because of the horizontal and vertical arching effects due to wall displacement and stress relief. In order to examine the earth pressure distribution of a cylindrical wall, model tests were performed in dry sand for the care of constant wall displacement with depth. Model test apparatus which can control wall displacement, wall friction, and wall shape ratio was developed. The effects of various factors that influence earth pressure acting on the cylindrical retaining wall of a shaft were investigated.

  • PDF