• Title/Summary/Keyword: Dry fog system

Search Result 14, Processing Time 0.03 seconds

Experimental study on the generation of ultrafine-sized dry fog and removal of particulate matter (초미세 크기의 마른 안개 생성과 이를 이용한 미세먼지 제거 연구)

  • Kiwoong Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.22 no.1
    • /
    • pp.34-39
    • /
    • 2024
  • With the fine particulate matter (PM) poses a serious threat to public health and the environment. The ultrafine PM in particular can cause serious problems. This study investigates the effectiveness of a submicron dry fog system in removing fine PM. Two methods are used to create fine dust particles: burning incense and utilizing an aerosol generator. Results indicate that the dry fog system effectively removes fine dust particles, with a removal efficiency of up to 81.9% for PM10 and 61.9% for PM2.5 after 30 minutes of operation. The dry fog, characterized by a mean size of approximately 1.5 ㎛, exhibits superior performance in comparison to traditional water spraying methods, attributed to reduced water consumption and increased contact probability between water droplets and dust particles. Furthermore, experiments with uniform-sized particles which sizes are 1 ㎛ and 2 ㎛ demonstrate the system's capability in removing ultrafine PM. The proposed submicron dry fog system shows promise for mitigating fine dust pollution in various industrial settings, offering advantages such as energy consumption and enhanced safety for workers and equipment.

Effect of Dry Fog Injection on Waste Decomposition in an Aerobic Landfill (호기성매립지에서 드라이포그 주입에 의한 폐기물분해 촉진에 관한 연구)

  • Park, Jin-Kyu;Lee, Byung-Sun;Yoon, Seok-Pyo;Lee, Nam-Hoon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.26 no.2
    • /
    • pp.43-51
    • /
    • 2018
  • The objective of this research was to assess the effect of moisture content and water injection method into the landfill on waste decomposition in an aerobic landfill. Firstly, respirometric experiments were performed in order to assess the effect of initial moisture content (20%, 30%, 40% and 50% respectively) on landfilled waste decomposition. The cumulative oxygen uptake and oxygen uptake rate were highly increased with the increase of initial moisture content. Secondly, lysimeter experiments showed that in comparison with the vertical injection method, dry fog system enhanced decomposition of organic wastes. Also, dry fog system provided uniform moisture distribution more than the vertical injection method within landfill.

Experimental Study on the Spray Characteristics of Low Pressure Fog Nozzles in Cooling Fog System (쿨링 포그 시스템의 저압 안개 노즐 분무특성에 대한 실험적 연구)

  • Ji Yeop, Kim;Cheol, Jeong;Won Jun, Kang;Jeong Ung, Kim;Jung Goo, Hong
    • Journal of ILASS-Korea
    • /
    • v.27 no.4
    • /
    • pp.173-180
    • /
    • 2022
  • Cooling fog is being used in various parts of society such as fine dust reduction, cleanliness, and temperature drop. Cooling fog has the advantage of low flow rate and ease of use compared to other spray systems. In the case of cooling fog, it was confirmed that the injection angle increased as the pressure increased and the nozzle diameter increased. In this study, the minimum injection angle was 33.61 degrees and the maximum injection angle was 107.38 degrees. It was confirmed that the larger the nozzle diameter and the smaller the pressure, the larger the droplet size. In addition, it was confirmed that the Sauter Mean Diameter (SMD) increased along the X and Y axis directions. It was confirmed that the size of the droplet decreases as it approaches the nozzle tip due to the characteristics of the nozzle design factor.

A Study on Reduction Effect of White Smoke Fog in Urban Detention Basin using a Fog Removal System (안개제거장치를 이용한 도심 저류지 시설에서의 안개 저감 효과 연구)

  • Lee, Kyu Hong;Lee, Sang Woo;Choi, Jun Sung;Lee, Sung Kyun;Park, Jihwan;Park, Seunghee
    • Journal of Korean Society of Disaster and Security
    • /
    • v.11 no.2
    • /
    • pp.69-74
    • /
    • 2018
  • Fog to which environmental impacts are sensitive has a danger to the safety of citizens due to the difficulty in predicting the specific area/time zone. Therefore, we propose a white smoke fog reduction technique using a fog removal device that can remove fog particles directly through dry air and anionic condensation nucleus instead of conventional passive countermeasures. In this study, to verify the effect of reducing fog and the effect of temperature on the white smoke fog which is frequently occurred in the detention basin. As a result, the visible distance of 100m or more was secured within 30 seconds, and it was confirmed that the fog reduction effect is more effective. Also, the lower the temperature, the larger the amount of white smoke fog was. However, the effect of reducing the white smoke fog by temperature was insignificant. Through this experiment, it was possible to verify the reduction effect of the white smoke fog generated in the detention basin through fog removal device.

Fine Dust Monitoring and Removal Method in Urban Construction Sites Using Autonomous Mobile Vehicle and Dry Fog System (자율이동체와 드라이포그를 활용한 도심지 건설현장 미세먼지 모니터링 및 대응 방안)

  • Kim, Kyoon Tai
    • Ecology and Resilient Infrastructure
    • /
    • v.6 no.4
    • /
    • pp.277-286
    • /
    • 2019
  • The construction industry is known to be one of the representative industries that generate fine dust. Therefore, reducing the amount of fine dust generated in construction sites is very important for the overall fine dust management. Based on this, this study proposed the fine dust measurement and removal technology combined with advanced technologies such as autonomous mobile vehicle IoT and DFS. The qualitative, quantitative and risk elimination effects that can be expected when applying the proposed technique are analyzed. The proposed technique will be validated through system development and field application and evaluated specific economics through cost analysis.

Effect of Greenhouse Cooling and Transplant Quality Using Geothermal Heat Pump System (지열-열펌프 시스템의 온실냉방 및 육묘 효과)

  • Lee, Jae-Han;Lee, Yong-Beom;Kwon, Joon-Kook;Kang, Nam-Jun;Kim, Hak-Joo;Choi, Young-Hah;Park, Jin-Myeon;Rhee, Han-Cheol
    • Journal of Bio-Environment Control
    • /
    • v.15 no.3
    • /
    • pp.211-216
    • /
    • 2006
  • This study was carried out to investigate the effect of greenhouse cooling by a geothermal heat pump system on greenhouse temperature and growth of vegetable transplants in summer season. Greenhouse air temperature in day time was $3-4^{\circ}C$ lower in fog plus shading system than in shading, while in night time that was $5-7^{\circ}C$ lower in geothermal heat pump (GHP) plus shading system compared to shading or fogplus shading. system. Plant height of cucumber, tomato and hot pepper transplants was shortened in GHP plus shading compared to shading or fog plus shading system. And Leaf area and dry weight were slightly decreased in GHP plus shading compared to the other systems. Therefore, healthy transplant index on cucumber, tomato and hot pepper was higher in GHP plusshading than in shading or fogplusshading system.

Eco-friendly Control of Whiteflies by Two-Fluid Fogging System with Natural Substances in Greenhouses (이류체 포그시스템 및 천연물을 이용한 친환경적 가루이 방제)

  • Kim, Sung-Eun;Lee, Sang-Don;Lee, Moon-Haeng;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.21 no.2
    • /
    • pp.114-119
    • /
    • 2012
  • We have conducted 4 experiments to develop the most environmental and effective use of the two-fluid fog system to prevent and exterminate whiteflies in tomato cultivation. In particular, these experiments used Vitamini tomatoes grown in stand-alone greenhouses at Buyeo Tomato Experiment Station as subjects. Each experiment utilized the fog system in a different way. The first experiment provided the control group, which was subject to the two-fluid fog system without additional humidity control. In the second experiment, the two-fluid fog system controlled the humidity level to be above 70%. The third and the fourth experiment utilized natural substances, which were 1.5 mg/L of Neem Oil and 2 mg/L of Oleic acid respectively, without additional humidity control. From the first experiment, we could observe that a simple use of the two-fluid fog system decreased the density of whiteflies in the greenhouses. This impact of the fog system on whiteflies was greater in the second experiment. By comparing the first and the second experiment, we concluded that whiteflies are more effectively prevented by maintaining a higher humidity level via the fog system's smaller water droplets that float in the air for longer time than the standard fog system in rather dry condition. In the third and the fourth experiments, the extermination level was 78% and 76.4% respectively, comparing only 53% in the first experiment without the humidity control. Therefore, using the natural substances in addition to the humidity control increases the extermination effectiveness. Considering the similar results from the 3rd and the 4th experiments, Oleic acid has a greater appeal for its lower price. Using the two-fluid fog system to both control the humidity on a daily basis and spray the substances for occasional extermination would reduce labor cost and increase production in an environmental way.

Humidification and Shading Affect Growth and Development of Cutting Propagated 'Maehyang' Strawberry (Fragaria × ananassa Duch.) at Propagation Stage (삽목번식 시 가습과 차광 처리에 따른 '매향' 딸기의 생육)

  • Kang, Dong Il;Jeong, Hai Kyoung;Park, Yoo Gyeong;Wei, Hao;Hu, Jiangtao;Jeong, Byoung Ryong
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.429-437
    • /
    • 2019
  • This study was conducted to examine the effect of humidification and shading during cutting propagation on growth and development of strawberry (Fragaria x ananassa Duch.) 'Maehyang' plants at a propagation stage. The runner cuttings were stuck on Nov. 23, 2017 in propagation benches set in a Venlo-type glasshouse. Four shading treatments, no shading (control, C), 55% shading with white lawn (W55), 55% black shading net (B55), or 100% black plastic film (B100) with either an intermittent fog system (H) or without fog system. The shading and fog systems were removed 2 weeks after sticking of strawberry cuttings. A nutrient solution for strawberry, which was developed by Yamazaki, was supplied once a day with electrical conductivity (EC) $1.6dS{\cdot}m^{-1}$ and pH 5.8. Growth parameters such as plant height, longest root, crown diameter, leaf chlorophyll, leaf area and fresh and dry weight were measured at 7 days and 26 days after sticking. There was no significant difference in growth of above-aerial part of strawberry. The overall growth of the strawberry roots was better grew by providing fog than that not provide fog. The root fresh weight and root dry weight after 26 days after sticking of strawberry cutting was the best in the treatment that provided fog system without shading (CH). The longest root after 26 days after sticking of strawberry cutting was the best in the treatments that provided fog system with either 55% white lawn (W55H) and 55% black shading net (B55H). These results suggest that morphogenesis of these plants were affected by humidification and shading types. In a broader perspective, these results can be used to optimize studies of other crops grown from cuttings.

Feasibility Study of Fine Dust Removal Technology in Construction Site (건설현장 미세먼지 제거기술의 타당성 분석)

  • Kim, Kyoon-Tai
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.120-121
    • /
    • 2019
  • The construction industry is known to be one of the representative industries that generate fine dust. Therefore, reducing the amount of fine dust generated in construction sites is very important for the overall fine dust management. Based on this, this study proposed the concept of fine dust measurement and removal technology combined with advanced technologies such as drones and IoT. The qualitative, quantitative and risk elimination effects that can be expected when applying the proposed technique are analyzed. We will verify the effectiveness of the proposed concept through system development and field application, and evaluate specific economic feasibility through cost analysis. The proposed concept will be validated through system development and field application and evaluated specific economics through cost analysis.

  • PDF

The Influence of Asian Dust, Haze, Mist, and Fog on Hospital Visits for Airway Diseases

  • Park, Jinkyeong;Lim, Myoung Nam;Hong, Yoonki;Kim, Woo Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.78 no.4
    • /
    • pp.326-335
    • /
    • 2015
  • Background: Asian dust is known to have harmful effects on the respiratory system. Respiratory conditions are also influenced by environmental conditions regardless of the presence of pollutants. The same pollutant can have different effects on the airway when the air is dry compared with when it is humid. We investigated hospital visits for chronic obstructive pulmonary disease (COPD) and asthma in relation to the environmental conditions. Methods: We conducted a retrospective study using the Korean National Health Insurance Service claims database of patients who visited hospitals in Chuncheon between January 2006 and April 2012. Asian dust, haze, mist, and fog days were determined using reports from the Korea Meteorological Administration. Hospital visits for asthma or COPD on the index days were compared with the comparison days. We used two-way case-crossover techniques with one to two matching. Results: The mean hospital visits for asthma and COPD were $59.37{\pm}34.01$ and $10.04{\pm}6.18$ per day, respectively. Hospital visits for asthma significantly increased at lag0 and lag1 for Asian dust (relative risk [RR], 1.10; 95% confidence interval [CI], 1.01-1.19; p<0.05) and haze (RR, 1.13; 95% CI, 1.06-1.22; p<0.05), but were significantly lower on misty (RR, 0.89; 95% CI, 0.80-0.99; p<0.05) and foggy (RR, 0.89; 95% CI, 0.84-0.93; p<0.05) days than on control days. The hospital visits for COPD also significantly increased on days with Asian dust (RR, 1.29; 95% CI, 1.05-1.59; p<0.05), and were significantly lower at lag4 for foggy days, compared with days without fog (RR, 0.85; 95% CI, 0.75-0.97; p<0.05). Conclusion: Asian dust showed an association with airway diseases and had effects for several days after the exposure. In contrast to Asian dust, mist and fog, which occur in humid air conditions, showed the opposite effects on airway diseases, after adjusting to the pollutants. It would require more research to investigate the effects of various air conditions on airway diseases.