• 제목/요약/키워드: Dry Air

검색결과 1,461건 처리시간 0.036초

의료종사자 손 소독용 알코올 젤의 사용량과 건조시간에 따른 항균효과의 비교 (Comparison of Antimicrobial Effect of Alcohol Gel according to the Amount and Drying Time in Health Personnel Hand Hygiene)

  • 지윤정;정재심
    • 대한간호학회지
    • /
    • 제43권3호
    • /
    • pp.305-311
    • /
    • 2013
  • Purpose: The purpose of this study was to compare the effect of alcohol gel according to the amount and drying time in health personnel hand hygiene and to promote in their practice adequate and effective hand hygiene. Methods: The crossover experimental study was performed with 14 volunteers. Hands were artificially contaminated with 5 mL of $10^8$ CFU/mL of Serratia marcescens (ATCC 14756) and four different alcohol gel hand hygiene methods varying by the amount of alcohol gel (2 mL vs. 1 mL) and drying time (complete vs. incomplete) were compared. Samples were collected by glove juice sampling procedures. Results: Mean log reduction values of the four different hand hygiene methods were $2.22{\pm}0.36$, $1.26{\pm}0.53$, $1.49{\pm}0.60$, $0.89{\pm}0.47$ respectively for the 4 groups: adequate amount (2mL) and complete dry (30 seconds rubbing followed by 2 min air-dry), inadequate amount (1 mL) and complete dry, adequate amount and incomplete dry (15 seconds rubbing and no air-dry), and inadequate amount and incomplete dry. The difference was statistically significant in the adequate amount and complete dry group compared to other three groups (p<.001). Conclusion: Only alcohol gel hand hygiene with adequate amount and complete drying was satisfactory by U.S. FDA-TFM efficacy requirements for antiseptic hand hygiene products.

냉각공기에 의한 환경 친화적 절삭가공기술 (Environment-Friendly Metal Cutting Technology using Cooled Air)

  • 이종항;조웅식;정준기;박철우;김영중
    • 한국정밀공학회지
    • /
    • 제18권6호
    • /
    • pp.114-120
    • /
    • 2001
  • It is necessary to develop a new metal cutting technology which does not use cutting fluid, since cutting fluid can have undesirable effect on workers's health and working environment. For this to be possible, it is necessary to replace the conventional method of using cutting fluid, whose basic functions are removing chip and heat, and providing lubrication between tool and chip. In this work, cooled air is utilized in order to replace cutting fluid. Experiments were carried out while cutting workpiece with HSS flat endmill under a variety of supply conditions for cooled air. Also the performance characteristics of the air cooling system. which was built for the experiments, were carefully analyzed. For the reliable operation of air cooling system. moisture contained in the cooled air had to be removed before being supplied to the workpiece and tools. It was found that depending on the amount of its flow rate the temperature of cooled air changes at the time of injection from the nozzle. The flow rate of cooled air also plays an important role in removing the accumulated chip on the workpiece. After comparing the flank wear for the three cases of using cooled air, cutting fluid, and pure dry technique, it was demonstrated that the level of flank wear was similar for the cases of cooled air and cutting fluid. The pure dry technique, however, showed higher level of flank wear than cooled air.

  • PDF

건식 바텀애시 굵은골재를 사용한 경량골재 콘크리트의 공학적 특성 (Engineering Properties of Lightweight Aggregate Concrete Using Dry Bottom Ash as Coarse Aggregate)

  • 성종현;선정수;최선미;복영재;김진만
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.166-167
    • /
    • 2013
  • Bottom ash, which is discharged through a wet process in a thermal power plant, contains much unburned coal due to quenching and much salt due to seawater. However, dry bottom ash discharged through a dry process contains low unburned coal and salt, and has light -weight due to many pores. Therefore, it is expected that it can be used as lightweight aggregate. This study deals with the basic properties of concrete used dry bottom ash as coarse aggregate. As a results, the concrete having high content of dry bottom ash aggregate showed high slump by using water reducing agent and its air content was within 5±1.5% as designed value, similarly to normal weight concrete. It also showed a lower compressive strength than 100% of crushed stone.

  • PDF

Reduction of the Wet Surface Heat Transfer Coefficients from Experimental Data

  • Kim, Nae-Hyun;Sim, Yong-Sub
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권1호
    • /
    • pp.37-49
    • /
    • 2004
  • Four different data reduction methods for the heat transfer coefficients from experimental data under dehumidifying conditions are compared. The four methods consist of two heat and mass transfer models and two fin efficiency models. Data are obtained from two heat exchanger samples having plain fins or wave fins. Comparison of the reduced heat transfer coefficients revealed that the single potential heat and mass transfer model yielded the humidity-independent heat transfer coefficients. Two fin efficiency models-enthalpy model and humidity model-yielded approximately the same fin efficiencies, and accordingly approximately the same heat transfer coefficients. The heat transfer coefficients under wet conditions were approximately the same as those of the dry conditions for the plain fin configuration. For the wave fin configuration, however, wet surface heat transfer coefficients were approximately 12% higher. The pressure drops of the wet surface were 10% to 45% larger than those of the dry surface.

Canopy를 고려한 대기오염물질의 건성침적모델에 관한 연구 (A Study on the Dry Deposition Model of Air Pollutants Considering Canopy Effect)

  • 이화운;박종길
    • 한국환경과학회지
    • /
    • 제4권2호
    • /
    • pp.151-158
    • /
    • 1995
  • A numerical model has been developed to predict the deposition of air pollutants considering canopy effect. In this model, the deposition velocity is calculated using the deposition resistances(aerodynamic resistance, viscosity resistance, surface resistance). Using the results, a comparative study was made between the model calculation and observation results. The calculated daily variation of deposition resistances and in daytime most of the model cases are well agreed with observation results, and a slight difference was found in nighttime. From the results, it is suggested that the present model is capable of estimating the deposition velocity of air Pollutants considering characteristics of canopy layer.

  • PDF

불평등전계에서의 건조공기/에폭시 복합절연물의 에폭시 두께에 따른 AC 파괴전압 분석 (Analysis of AC Breakdown Voltage accoding to epoxy thickness of Composite Insulation for Dry-Air/Epoxy under non-uniform electric field)

  • 허준;이승수;임기조;정해은;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.113-114
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

차음성능이 향상된 경량벽체 개발 및 성능평가 연구 (A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System)

  • 이병권;배상환;홍천화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

냉각액 최소화를 통한 환경 친화적 연삭 가공기술 연구 (A Study on the Environment-Friendly Grinding Technology through Minimizing Coolant)

  • 최헌종;이석우;김대중;정해도
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.796-799
    • /
    • 2000
  • The concern of environmental problems by using coolant required the recycling technologies of used coolant and development of environmental-firiendly coolant Some methods have been developing. Those are the dry grinding with compressed cold air and grinding with misted coolant. The farmer is effective in the cooling effect, but has not the performance of lubrication. Otherwise, the latter can satisfy both of them and also decrease the environmental pollution. This paper tried to analyze the cooling effect and surface integral of coolant, compressed cold air, mist through measuring the temperature of grind point and grinding force. Especially, the grinding method with misted coolant according to parameters was done. So, the finding method with misted coolant proved to be effective as one of methods to decrease the environmental pollution.

  • PDF