• Title/Summary/Keyword: Drug administration

Search Result 3,428, Processing Time 0.035 seconds

Evaluation of Microbial Contamination in the Manufacturing Process of Non-Heated Frozen Rice Cakes (비가열 냉동떡의 제조공정에 대한 미생물 오염도 평가)

  • Yong-Sik, Yoon;Eun-In, Yang;Young-Soo, Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.6
    • /
    • pp.400-410
    • /
    • 2022
  • This study was performed to analyze the microbial contamination levels of three non-heated rice cake manufacturers in terms of seasonal manufacturing process and to investigate the effects of summertime soaking on contamination levels and temperature-controlled soaking in water on reduction in microbial levels. The total aerobic bacteria (TAB) ranged from 2.69 log CFU/g to 5.08 log CFU/g in the produce, but the microbial contamination increased sharply during soaking. The levels of TAB and coliforms during summer soaking were 7.01 and 3.96 log CFU/g, respectively, and this was significantly higher than those in other seasons. The contamination level was high in the subsequent freezing, with the TAB level (6.24 log CFU/g) exceeding the legal standard. The temperature of soaking water in summer increased from 19.1℃ to 26.8℃ after 12 h of soaking. The microbial contamination was significantly high commensurate with increased soaking time, and the TAB level in the frozen process exceeded the legal standard from 9 h of soaking. The use of ice packs to prevent the increase in temperature of the soaking water in summer resulted in maintenance of temperature at 20.1℃ for up to 12 h. The average TAB value in the freezing process was 4.42 log CFU/g after 12 h of soaking, and this is 1.77 log CFU/g lower than that before. Based on these results, it was determined that controlling the soaking time and water temperature are essential for the production of a safe unheated frozen rice cake. The safety of the HACCP system could be established by applying these preventive management standards.

Comparative Analysis of Community Health Practitioner's Activities and Primary Health Post Management Before and After Officialization of Community Health practitioner (보건진료원의 정규직화 전과 후의 보건진료원 활동 및 보건진료소 관리운영체계의 비교 분석)

  • Yun, Suk-Ok;Jung, Moon-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.19 no.2
    • /
    • pp.141-158
    • /
    • 1994
  • To provide better health care services to the rural population, the government has made the Community Health Practitioner(CHP) a regular government official from April 1, 1992. This study was carried out to study the impact of officialization of CHP on the activities and management system of Primary Health Post(PHP). Fifty PHPs were selected by two stage sampling, cluster and simple random, from 595 PHPs in Kyungnam and Kyungpook provinces. Data were collected by a personal interview with CHPs and review of records and reports kept in the PHPs. The study was done for the periods of January 1-March 31, 1992 (before officialization) and January 1-March 31, 1993 (after officialization). Ninety-six percent of the CHPs wanted to become a regular government official in the hope of better job security and higher salary. The proportion of CHPs who were proud of their iob was increased from 24% to 46% after officialization. Those CHPs who felt insecure for their job decreased from 30% to 10%. Monthly salary was increased by 34% from 802,600 Won to 1,076,000 Won and 90% of the CHPs were satisfied with their salary, also more CHPs responded that they have autonomy in their work planning, implementation of plan, management of the post, and evaluation of their activity. There were no appreciable changes in such CHPs' activities as assessment of local health resources, drawing map for the catchment area, utilization of community organization, grasping the current population structure in the catchment area, keeping the family health records, individual and group health education, and school health service. However, the number of home visits was increased from 13.6 times on the average per month per CHP to 27.5 times. More mothers and children were referred to other medical facilities for the immunization and family planning services. Average number of patients of hypertension, cancer, and diabetes in three months period was decreased from 12.7 to 11.6, from 1.5 to 1.2, and 4.3 to 3.4, respectively. Records for the patient care, drug management, and equipment were well kept but not for other records. The level of record keeping was not changed after officialization. The proportion of PHPs which had support from the health center was increased for drug supply from 14.0% to 30.0%, for consumable commodities from 22.0% to 52.0%, for maintenance of PHP from 54.0% to 68.0%, for supply of health education materials from 34.0% to 44.0%, and supply of equipment from 54.0% to 58.0%. Total monthly revenue of a PHP was increased by about 50,000 Won; increased by 22,000 Won in patient care and 34,700 Won in the government subsidy but decreased in the membership due and donation. However, there was no remarkable changes in the expenditure. The proportion of PHPs which had received official notes from the health center for the purpose of guidance and supervision of the CHPs was increased from 20% to 38% during three months period and the average number of telephone call for supervision from the health center per PHP was increased from 1.8 to 2.1 times(p<0.01). However, the proportion of PHPs that had supervisory visit and conference was reduced from 79% to 62%, and from 88% to 74%, respectively. The proportion of CHPs who maintained a cooperative relationship with Myun Health Workers was reduced from 42% to 36%, that with the director of health center from 46% to 24%, that with the chief of public health administration section from 56% to 36%, and that with the chairman of PHP management council from 62% to 38%. Most of the CHPs (92% before and 82% after officialization) stated that the PHP management council is not helpful for the PHP. CHPs who considered the PHP management council unnecessary increased from 4% to 16%(p<0.05). Suggestions made by the CHPs for the improvement of CHP program included emphasis on health education, assurance of autonomy for PHP management, increase of the kind of drugs that can be dispensed by CHPs, and appointment of an experienced CHP in the health center as the supervisor of CHPs. The results of this study revealed that the role and function of CHPs as reflected in their activities have not been changed after officialization. However, satisfaction in job security and salary was improved as well as the autonomy. Support of health center to the PHP was improved but more official notes were sent to the PHPs which required the CHPs more paper works. Number of telephone calls for supervision was increased but there was little administrative and technical guidance for the CHP activities.

  • PDF

Analysis of Patient Effective Dose in PET/CT; Using CT Dosimetry Programs (CT 선량 측정 프로그램을 이용한 PET/CT 검사 환자의 예측 유효 선량의 분석)

  • Kim, Jung-Sun;Jung, Woo-Young;Park, Seung-Yong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.77-82
    • /
    • 2010
  • Purpose: As PET/CT come into wide use, it caused increasing of expose in clinical use. Therefore, Korea Food and Drug Administration issued Patient DRL (Diagnostic Reference Level) in CT scan. In this study, to build the basis of patient dose reduction, we analyzed effective dose in transmission scan with CT scan. Materials and Methods: From February, 2010 to March 180 patients (age: $55{\pm}16$, weight: $61.0{\pm}10.4$ kg) who examined $^{18}F$-FDG PET/CT in Asan Medical Center. Biograph Truepoint 40 (SIEMENS, GERMANY), Biograph Sensation 16 (SIEMENS, GERMANY) and Discovery STe8 (GE healthcare, USA) were used in this study. Per each male and female average of 30 patients doses were analyzed by one. Automatic exposure control system for controlling the dose can affect the largest by a patient's body weight less than 50 kg, 50-60 kg less, 60 kg more than the average of the three groups were divided doses. We compared that measured value of CT-expo v1.7 and ImPACT v1.0. The relationship between body weight and the effective dose were analyzed. Results: When using CT-Expo V1.7, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.46{\pm}1.18$ mSv, $9.36{\pm}1.96 $mSv and $9.36{\pm}1.96$ mSv for 30 male patients respectably $6.29{\pm}0.97$ mSv, $10.02{\pm}2.42$ mSv and $9.05{\pm}2.27$ mSv for 30 female patients respectably. When using ImPACT v1.0, effective dose with BIO40, BIO16 and DSTe8 respectably were $6.54{\pm}1.21$ mSv, $8.36{\pm}1.69$ mSv and $9.74{\pm}2.55$Sv for 30 male patients respectably $5.87{\pm}1.09$ mSv, $8.43{\pm}1.89$ mSv and $9.19{\pm}2.29$ mSv for female patients respectably. When divided three groups which were under 50 kg, 50~60 kg and over 60 kg respectably were 6.27 mSv, 7.67 mSv and 9.33 mSv respectably using CT-Expo V1.7, 5.62 mSv, 7.22 mSv and 8.91 mSv respectably using ImPACT v1.0. Weight and the effective dose coefficient analysis showed a very strong positive correlation(r=743, r=0.693). Conclusion: Using such a dose evaluation programs, easier to predict and evaluate the effective dose possible without performing phantom study and such dose evaluation programs could be used to collect basic data for CT dose management.

  • PDF

The study of thermal change by chemoport in radiofrequency hyperthermia (고주파 온열치료시 케모포트의 열적 변화 연구)

  • Lee, seung hoon;Lee, sun young;Gim, yang soo;Kwak, Keun tak;Yang, myung sik;Cha, seok yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.97-106
    • /
    • 2015
  • Purpose : This study evaluate the thermal changes caused by use of the chemoport for drug administration and blood sampling during radiofrequency hyperthermia. Materials and Methods : 20cm size of the electrode radio frequency hyperthermia (EHY-2000, Oncotherm KFT, Hungary) was used. The materials of the chemoport in our hospital from currently being used therapy are plastics, metal-containing epoxy and titanium that were made of the diameter 20 cm, height 20 cm insertion of the self-made cylindrical Agar phantom to measure the temperature. Thermoscope(TM-100, Oncotherm Kft, Hungary) and Sim4Life (Ver2.0, Zurich, Switzerland) was compared to the actual measured temperature. Each of the electrode measurement position is the central axis and the central axis side 1.5 cm, 0 cm(surface), 0.5 cm, 1.8 cm, 2.8 cm in depth was respectively measured. The measured temperature is $24.5{\sim}25.5^{\circ}C$, humidity is 30% ~ 32%. In five-minute intervals to measure the output power of 100W, 60 min. Results : In the electrode central axis 2.8 cm depth, the maximum temperature of the case with the unused of the chemoport, plastic, epoxy and titanium were respectively $39.51^{\circ}C$, $39.11^{\circ}C$, $38.81^{\circ}C$, $40.64^{\circ}C$, simulated experimental data were $42.20^{\circ}C$, $41.50^{\circ}C$, $40.70^{\circ}C$, $42.50^{\circ}C$. And in the central axis electrode side 1.5 cm depth 2.8 cm, mesured data were $39.37^{\circ}C$, $39.32^{\circ}C$, $39.20^{\circ}C$, $39.46^{\circ}C$, the simulated experimental data were $42.00^{\circ}C$, $41.80^{\circ}C$, $41.20^{\circ}C$, $42.30^{\circ}C$. Conclusion : The thermal variations were caused by radiofrequency electromagnetic field surrounding the chemoport showed lower than in the case of unused in non-conductive plastic material and epoxy material, the titanum chemoport that made of conductor materials showed a slight differences. This is due to the metal contents in the chemoport and the geometry of the chemoport. And because it uses a low radio frequency bandwidth of the used equipment. That is, although use of the chemoport in this study do not significantly affect the surrounding tissue. That is, because the thermal change is insignificant, it is suggested that the hazard of the chemoport used in this study doesn't need to be considered.

  • PDF

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Analysis of Critical Control Points through Field Assessment of Sanitation Management Practices in Foodservice Establishments (현장실사를 통한 급식유헝별 위생관리실태 분석)

  • Kwak Tong-Kyung;Lee Kyung-Mi;Chang Hye-Ja;Kang Yong-Jae;Hong Wan-Soo;Moon Hye-Kyung
    • Korean journal of food and cookery science
    • /
    • v.21 no.3 s.87
    • /
    • pp.290-300
    • /
    • 2005
  • Increased sanitation management of foodservice establishments is required because most of the reported foodborne-disease outbreaks were in the foodservice industry. The purpose of this study was to determine the important control points for good sanitation. In this study, we inspected twenty foodservice establishments in Seoul, Kyunggi, Kyungnam with a self-developed monitoring tool. These foodservice establishments included secondary schools, universities, and industries. Six of them had appointed as the HACCP-certified establishments from the Korea Food and Drug Administration. The inspection was conducted from June to August in 2002. The inspection tool consisted of nine dimensions and sixty-five items. The dimensions were 'personal sanitation', 'supply of raw food', 'food storage', 'handling of raw food and ready-to-eat', 'cleaning and sterilization', 'waste control', 'pest control', and 'control of establishment and equipment' The highest possible score of this inspection tool is 105 points. Statistical data analysis was completed using the SPSS Package(11.0) for descriptive analysis Kruskal-Wallis. The score for the secondary schools (83.6 points) was higher than for the others and number of in compliance item was 50.9 on average. Therefore, we concluded that the secondary schools' sanitation condition was good. The foodservice establishments acquired HACCP certification was 89.7 points, which was significantly higher than that of establishments not applying foodservices in total score. Instituting the HACCP system in a foodservice is very effective for sanitation management. Many out of the compliance observations were found in the dimensions of 'waste control', 'control of establishment and equipment', and 'supply of raw food' 'Clean condition of refrigerator' item was $65\%$ out of the compliance that was the highest percent in this study. 'Notify and observance of heating/reheating temperature' was $45\%$ out of compliance. Items which were over $30\%$ out of compliance were 'sterilization of knifes and chopping boards in cooking', 'education of workers', 'maintain refrigerator temperature blow $5^{\circ}C$', and 'countermeasure of infection workers' In the results, most of the foodservice establishments were poorly managed in temperature control and cross-contamination. The important control points revealed in this study were preventing contamination, cooking temperature compliance, management of raw food and refrigerator. Therefore foodservice establishments should pay attention to education and training about important control points. The systematic sanitation management monitoring tool developed in this study can be effectively applied for conducting self-inspection and improving the sanitary conditions of their own foodservice operations.

Clinical Study of Corrosive Esophagitis (부식성 식도염에 관한 임상적 고찰)

  • 이원상;정승규;최홍식;김상기;김광문;홍원표
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.6-7
    • /
    • 1981
  • With the improvement of living standard and educational level of the people, there is an increasing awareness about the dangers of toxic substances and lethal drugs. In addition to the above, the governmental control of these substances has led to a progressive decrease in the accidents with corrosive substances. However there are still sporadic incidences of suicidal attempts with the substances due to the unbalance between the cultural development in society and individual emotion. The problem is explained by the fact that there is a variety of corrosive agents easily available to the people due to the considerable industrial development and industrialization. Salzen(1920), Bokey(1924) were pioneers on the subject of the corrosive esophagitis and esophageal stenosis by dilatation method. Since then there had been a continuing improvement on the subject with researches on various acid(Pitkin, 1935, Carmody, 1936) and alkali (Tree, 1942, Tucker, 1951) corrosive agents, and the use of steroid (Spain, 1950) and antibiotics. Recently, early esophagoscopic examination is emphasized on the purpose of determining the way of the treatment in corrosive esophagitis patients. In order to find the effective treatment of such patients in future, the authors selected 96 corrosive esophagitis patients who were admitted and treated at the ENT department of Severance hospital from 1971 to March, 1981 to attempt a clinical study. 1. Sex incidence……male: female=1 : 1.7, Age incidence……21-30 years age group; 38 cases (39.6%). 2. Suicidal attempt……80 cases(83.3%), Accidental ingestion……16 cases (16.7%). Among those who ingested the substance accidentally, children below ten years were most numerous with nine patients. 3. Incidence acetic acid……41 cases(41.8%), lye…20 cases (20.4%), HCI……17 cases (17.3%). There was a trend of rapid rise in the incidence of acidic corrosive agents especially acetic acid. 4. Lavage……57 cases (81.1%). 5. Nasogastric tube insertion……80 cases (83.3%), No insertion……16 cases(16.7%), late admittance……10 cases, failure…4 cases, other……2 cases. 6. Tracheostomy……17 cases(17.7%), respiratory problems(75.0%), mental problems (25.0%). 7. Early endoscopy……11 cases(11.5%), within 48 hours……6 cases (54.4%). Endoscopic results; moderate mucosal ulceration…8 cases (72.7%), mild mucosal erythema……2 cases (18.2%), severe mucosal ulceration……1 cases (9.1%) and among those who took early endoscopic examination; 6 patients were confirmed mild lesion and so they were discharged after endoscopy. Average period of admittance in the cases of nasogastric tube insertion was 4 weeks. 8. Nasogastric tube indwelling period……average 11.6 days, recently our treatment trend in the corrosive esophagitis patients with nasogastric tube indwelling is determined according to the finding of early endoscopy. 9. The No. of patients who didn't given and delayed administration of steroid……7 cases(48.9%): causes; kind of drug(acid, unknown)……12 cases, late admittance……11 cases, mild case…9 cases, contraindication……7 cases, other …8 cases. 10. Management of stricture; bougienage……7 cases, feeding gastrostomy……6 cases, other surgical management……4 cases. 11. Complication……27 cases(28.1%); cardio-pulmonary……10 cases, visceral rupture……8 cases, massive bleeding……6 cases, renal failure……4 cases, other…2 cases, expire and moribund discharge…8 cases. 12. No. of follow-up case……23 cases; esophageal stricture……13 cases and site of stricture; hypopharynx……1 case, mid third of esophagus…5 cases, upper third of esophagus…3 cases, lower third of esophagus……3 cases pylorus……1 case, diffuse esophageal stenosis……1 case.

  • PDF

Comparative analysis of Glomerular Filtration Rate measurement and estimated glomerular filtration rate using 99mTc-DTPA in kidney transplant donors. (신장이식 공여자에서 99mTc-DTPA를 이용한 Glomerular Filtration Rate 측정과 추정사구체여과율의 비교분석)

  • Cheon, Jun Hong;Yoo, Nam Ho;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.35-40
    • /
    • 2021
  • Purpose Glomerular filtration rate(GFR) is an important indicator for the diagnosis, treatment, and follow-up of kidney disease and is also used by healthy individuals for drug use and evaluating kidney function in donors. The gold standard method of the GFR test is to measure by continuously injecting the inulin which is extrinsic marker, but it takes a long time and the test method is complicated. so, the method of measuring the serum concentration of creatinine is used. Estimated glomerular filtration rate (eGFR) is used instead. However, creatinine is known to be affected by age, gender, muscle mass, etc. eGFR formulas that are currently used include the Cockroft-Gault formula, the modification of diet in renal disease (MDRD) formula, and the chronic kidney disease epidemilogy collaboration (CKD-EPI) formula for adults. For children, the Schwartz formula is used. Measurement of GFR using 51Cr-EDTA (diethylenetriamine tetraacetic acid), 99mTc-DTPA (diethylenetriamine pentaacetic acid) can replace inulin and is currently in use. Therefore, We compared the GFR measured using 99mTc-DTPA with the eGFR using CKD-EPI formula. Materials and Methods For 200 kidney transplant donors who visited Asan medical center.(96 males, 104 females, 47.3 years ± 12.7 years old) GFR was measured using plasma(Two-plasma-sample-method, TPSM) obtained by intravenous administration of 99mTc-DTPA(0.5mCi, 18.5 MBq). eGFR was derived using CKD-EPI formula based on serum creatinine concentration. Results GFR average measured using 99mTc-DTPA for 200 kidney transplant donors is 97.27±19.46(ml/min/1.73m2), and the eGFR average value using the CKD-EPI formula is 96.84±17.74(ml/min/1.73m2), The concentration of serum creatinine is 0.84±0.39(mg/dL). Regression formula of 99mTc-DTPA GFR for serum creatinine-based eGFR was Y = 0.5073X + 48.186, and the correlation coefficient was 0.698 (P<0.01). Difference (%) was 1.52±18.28. Conclusion The correlation coefficient between the 99mTc-DTPA and the eGFR derived on serum creatinine concentration was confirmed to be moderate. This is estimated that eGFR is affected by external factors such as age, gender, and muscle mass and use of formulas made for kidney disease patients. By using 99mTc-DTPA, we can provide reliable GFR results, which is used for diagnosis, treatment and observation of kidney disease, and kidney evaluation of kidney transplant patients.