• Title/Summary/Keyword: Droplet Size and Velocity

Search Result 156, Processing Time 0.021 seconds

CHARACTERISTICS OF WALL IMPINGEMENT AT ELEVATED TEMPERATURE CONDITIONS ON GDI SPRAY

  • Park, J.;Im, K.S.;Kim, H.;Lai, M.C.
    • International Journal of Automotive Technology
    • /
    • v.5 no.3
    • /
    • pp.155-164
    • /
    • 2004
  • The direct injection gasoline spray-wall interaction was characterized inside a heated pressurized chamber using various visualization techniques, including high-speed laser-sheet macroscopic and microscopic movies up to 25,000 frames per second, shadowgraph, and double-spark particle image velocimetry. Two hollow cone high-pressure swirl injectors having different cone angles were used to inject gasoline onto a heated plate at two different impingement angles. Based on the visualization results, the overall transient spray impingement structure, fuel film formation, and preliminary droplet size and velocity were analyzed. The results show that upward spray vortex inside the spray is more obvious at elevated temperature condition, particularly for the wide-cone-angle injector, due to the vaporization of small droplets and decreased air density. Film build-up on the surface is clearly observed at both ambient and elevated temperature, especially for narrow cone spray. Vapor phase appears at both ambient and elevated temperature conditions, particularly in the toroidal vortex and impingement plume. More rapid impingement and faster horizontal spread after impingement are observed for elevated temperature conditions. Droplet rebounding and film break-up are clearly observed. Post-impingement droplets are significantly smaller than pre-impingement droplets with a more horizontal velocity component regardless of the wall temperature and impingement angle condition.

Atomization Characteristics of Three Types of Swirl Injectors (세 가지 유형 와류 분사기들의 미립화 특성)

  • Hadong Jung;Jonghyeon Ahn;Kyubok Ahn
    • Journal of ILASS-Korea
    • /
    • v.28 no.2
    • /
    • pp.75-88
    • /
    • 2023
  • In this paper, the atomization characteristics of bi-swirl coaxial injectors for a 420 N-class bipropellant thruster were investigated. Three types of injectors, namely closed-type, open-type, and screw-type, were manufactured and designed to have the same spray angle and injection pressure drop. Water was used as a simulant, and cold-flow tests were conducted under ambient temperature and pressure conditions. Since the inner and outer injectors were designed to be the same type, only the inner fuel injectors that were easy to measure were used. Using a phase doppler particle analyzer, the velocity and diameter of atomized droplets were measured. Closed-type swirl injector exhibited droplet distributions with relatively high velocities and small SMD compared to the other two injectors. Open-type swirl injector formed droplets with reverse velocities in the center region and had a large recirculation zone. Screw-type swirl injector showed a sharp decrease in droplet velocity and size with radial distance from the liquid film breakup point. For the same design requirements, the closed-type swirl injector has superior atomization performance.

Measurement of Sizes and Velocities of Spray Droplets by Image Processing Method (영상 처리에 의한 분무 액적의 크기 및 속도 추출)

  • Choo, Y.J.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.7 no.4
    • /
    • pp.23-31
    • /
    • 2002
  • In this study, the sizes and velocities of droplets in sprays were measured by image processing method from digital images of local region of sprays. The morphological method based on the Euclidean distance transform, Watershed separation, and perimeter image was adopted for the recognition and separation of overlapped particles. The match probability method was used for the particle tracking and pairing. The measurement results show that the present method may be reliable for the analysis of the motion and distribution of droplets produced by spray and atomization devices.

  • PDF

Study on Spray Atomization Characteristics Depending on the Operating Parameters of Urea Injector (요소수 인젝터의 작동 변수에 따른 분무미립화 성능에 관한 연구)

  • Kim, Donghwan;Park, Junkyu;Park, Sungwook
    • Journal of ILASS-Korea
    • /
    • v.24 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • This study was carried out to analyze the spray characteristics as a function of the operating parameters of urea injector used in Urea-SCR system of passenger diesel vehicle. Spray visualization and PDPA experiment were performed to analyze the macroscopic spray development and atomization performance of urea-water-solution. For the urea injector, the deformation of the spray head does not appear to be significant because it operates at a low pressure conditions, and the liquid core and primary droplet are observed throughout the operating conditions. No increase in atomization is seen when the operating pressure is increased, and the spray develops linearly due to poor atomization characteristics. The macroscopic spray behavior of the low-pressure urea injector is predictable through the modification of the Hiroyasu equation.

Numerical Investigation of a Steady Non-Evaporating Hollow-Cone Spray Interacting with an Annular Air Jet (정상 할로우 콘 분무와 환형 공기 제트의 상호작용에 관한 수치적 연구)

  • Kim, Woo-Tae;Huh, Kang-Y.
    • Journal of ILASS-Korea
    • /
    • v.5 no.2
    • /
    • pp.43-52
    • /
    • 2000
  • Numerical simulation of steady, non-evaporating hollow-cone sprays interacting with concentric annular air jets is performed using the discrete stochastic particle method in KIVA. The spray characteristics such as SMD, mean droplet velocity, liquid volume flux, air/liquid mass ratio, and droplet number density arc obtained and compared with the measurements involving different air flow rates in large and small annuli. Overall satisfactory agreement is achieved between calculation and experiment except for the deviation in the downstream SMD arising from uncertainty in the size distribution function at injection, and inaccuracy in the averaged spray parameters due to the small volumes of axisymmetric 2-D sector meshes close to the axis.

  • PDF

An Experimental Study on the Characteristic of Sprays and Spray Flames by Twin-Fluid Atomizer (2유체 분사노즐을 이용한 분무 및 연소특성에 관한 실험적 연구)

  • 백민수;오상헌
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.2
    • /
    • pp.548-558
    • /
    • 1995
  • An experimental investigation has been conducted to study the spray and combustion characteristics using the air-assisted twin fluid atomizer. Axial mean and fluctuating velocity components as well as drop-size distributions in non-reaction spray were measured with a nonintrusive phase doppler technique. Droplet number density distributions were also visualized using high speed CCD camera. Locations of spray and flame boundaries are obtained by direct photographic method. It is confirmed that at the fixed fuel flow rate, the increase of the atomizing air flow causes improvements on both spray and combustion characteristics under stable flame conditions. Internal group combustion modes where flame is located inside the spray boundary are observed to exist in the upstream region of higher droplet number density.

Error Evaluation on Flame Measurement in Combustion Field (연소장내 화염계측 오차 평가)

  • Yang, Young Joon;Heo, Tae Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.167-169
    • /
    • 2014
  • Spray combustion has been used in many industrial fields, for instance, such as diesel engines, gas turbines and industrial furnaces, and furthermore various measurement techniques have been applied to elucidate the phenomenon of spray combustion. In order to measure simultaneously the droplet velocity and the droplet size of spray, Phase Doppler Anemometry (PDA) was frequently used in spray combustion. However, the measurement error is occurred due to existence of flame, which is considered as influencing the precision of measurement. Therefore, the purpose of this study is experimentally to conduct the systematic evaluation on the measurement error when PDA measurement is applied to combustion field.

  • PDF

An Experimental Study of the Micro Turbojet Engine Fuel Injection System

  • Choi, Hyun-Kyung;Choi, Seong-Man;Lee, Dong-Hun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.1-5
    • /
    • 2008
  • An experimental study was performed to develop the rotational fuel injection system of the micro turbojet engine. In this system, fuel is sprayed by centrifugal forces of engine shaft. The test rig was designed and manufactured to get droplet information on combustion space. This experimental apparatus consist of a high speed rotational device(Air-Spindle), fuel feeder, rotational fuel injector and acrylic case. To understand spray characteristics, spray droplet size, velocity and distribution were measured by PDPA (Phase Doppler Particle Analyzer) and spray was visualized by using Nd-Yag laser-based flash photography. From the test results, the length of liquid column from injection orifice is controlled by the rotational speeds and Sauter Mean Diameter(SMD) is decreased with rotational speed. Also, Sauter Mean Diameter is increased as increasing mass flow rate at same rotational speeds.

  • PDF

The evaluation of error due to flame in the measurement using phase doppler anemometry (위상도플러 유속계를 이용한 계측에 있어서의 화염에 기인한 오차의 평가)

  • Yang, Young-Joon
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.313-321
    • /
    • 2005
  • Spray combustion has been used in many industrial fields, for instance, such as diesel engines, gas turbines and industrial furnaces, and furthermore various measurement techniques have been applied to elucidate the phenomenon of spray combustion. In order to measure simultaneously the droplet velocity and the droplet size of spray, phase doppler anemometry (PDA) was frequently used in spray combustion. However, the measurement error is occurred due to existence of flame, which is considered as influencing the precision of measurement. Therefore, the purpose of this study is experimentally to conduct the systematic evaluation on the measurement error when PDA measurement is applied to combustion field.

Molecular Dynamics Study on the Binary Collision of Nanometer-Sized Droplets of Liquid Argon

  • Chun, In-Beom;Ha, Man-Yeong;Jang, Joon-Kyung;Yoon, Hyun-Sik
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.2027-2031
    • /
    • 2011
  • Molecular dynamics simulation is used to study the binary collisions of nanometer-sized droplets of argon in the presence of a surrounding gas. By systematically varying the droplet size, the impact parameter and the velocity of collision, the outcome of such collisions were examined and they can be classified into coalescence, separation and shattering. If one of the colliding droplets is half or less than the other in diameter, a shattering is not possible to occur. The threshold of impact parameter for a given separation was studied by adjusting the Weber number. Overall nanoscale droplets were more likely to coalesce than the macroscopic sized ones due to their high surface-to-volume ratio.