• 제목/요약/키워드: Drop size distribution

검색결과 156건 처리시간 0.021초

A Study on Classification of Chinese Men's Body Types - Focused in Beijing and Shanghai -

  • Lim, Soon;Sohn, Hee-Soon;Kim, Jee-Yeon
    • 패션비즈니스
    • /
    • 제6권6호
    • /
    • pp.78-88
    • /
    • 2002
  • The purpose of this study is to provide for some basic data useful to production of the apparels fit and measured well for the Chinese men. For this purpose, 389 men aged between 20 and 49 and living in Beijing and Shanghai, China were sampled to be measured for their constitutions. Then, their constitutions were classified and thereupon, according to the Men's Wear Specifications (GB/T 1335.1-1997), National Standards of People's Republic of China. The collected data were statistically processed using SAS 6.12 for technical statistical analysis, correlation analysis, factor analysis, group-wise analysis. The results of this study can be summarized as follows; 1. As a result of the factor analysis aiming to determine Chinese men's constitutional components, five components could be identified: constitutional obesity, lateral body size, longitudinal body size, shoulder and back width, and shoulder drooping. 2. As a result of classifying Chinese men's constitutions according to drop measurements, four types could be identified. Y type had the lowest obesity and the highest longitudinal body size. A type had a lower obesity and had an average longitudinal body size. B Type had the second highest obesity, the smallest longitudinal body size and shoulders/back width. C Type had the highest obesity, upper body length and shoulders/back width. 3. In terms of distribution, 'B' type (39.10%) of the sample, followed by 'A' type (29.26%), 'C' type (19.95%) and 'Y' type (11.70%). In all, the results of this study suggests that 'B' type represents the Chinese men in contrast with GB specifying that 'A' type represents the Chinese men. On the other hand, Beijing region was dominated most by 'B' type (37.06%), followed by 'A' type (28.82%), 'C' type (22.35%) and 'Y' type (11.76%), while Shanghai region was dominated most by 'B' type (41.13%), followed by 'A' type (31.21%), 'C' type (19.15%) and 'Y' type (8.51%).

중국(中國) 수출(輸出) 남성(男性) 기성복(旣成服) 치수에 관(關)한 연구(硏究) -한국(韓國) 남성복(男性服) 치수를 중심(中心)으로 한 중국(中國) 남성복(男性服) 대응(對應)치수의 설정(設定) 및 제시(提示)-

  • 심부자
    • 패션비즈니스
    • /
    • 제11권2호
    • /
    • pp.155-171
    • /
    • 2007
  • This research aims to present the corresponding dimensions of China men's clothes on the basis of size specification of Korea men's suits. The results of this study, with the cooperation of Sejung Company exporting men's clothes to Ningbo City, Zhejiang Province in China, are as follows: 1. Based on the drop standard of KS K 0050, the body types of Chinese men in their 20s were classified. A body types were 55.77%, Y body types were 32.16%, B body types were 11.55% and BB body types were 1.51%. 2. According to the criteria of ready-made dimensions of normal body type suggested in Korea Standards, and in consideration of the basic distribution reality of body dimensions, representative 5 sizes were selected. 3. Research jackets by different sizes were produced and went through wearing tests. The means of 1st wearing test were 3.86, 4.09, 4.09, 3.57, and 3.69. The mean of 2nd wearing test of 88-73-170 size was 4.32. 4. The corresponding size specification of China men's clothes based on those of Korea men's suits were presented here, showing product sizes and physical items in detail.

PLIF 기법을 이용한 액체로켓용 충돌분사 인젝터의 분무분포 특성 해석 (Analysis of the Spray Distribution Characterization of Impinging Jet Injectors for Liquid Rockets Using PLIF Technique)

  • 정기훈;윤영빈;황상순
    • 한국추진공학회지
    • /
    • 제4권1호
    • /
    • pp.36-45
    • /
    • 2000
  • 지금까지의 충돌분무에 대한 연구는 제트의 충돌시 형성되는 액막의 분열 과정을 이해하고 이를 모델링하는데 초점을 두어왔기 때문에 실질적으로 연소 효율에 가장 큰 영향을 미치는 연료의 공간분포 특성에 대한 연구가 부족하였다. 따라서 본 연구에서는 like-doublet 충돌분사 노즐을 사용하여 연료 유량 플럭스의 단면분포 특성을 연구하였다. PDPA(Phase Doppler Particle Analyzer)를 통해 액적의 크기를 측정한 기존의 방법은 연료의 평면적인 분포특성을 이해하는데 상당히 제한적이었기 때문에 평면 레이저 유도형광기법(PLE : Planar Laser Induced Fluorescence)을 이용하여 분무의 단면 분포를 측정하였고, 직접사진을 통하여 액적의 크기도 측정하여 PLIF의 결과와 비교하였다.

  • PDF

강수의 물리적 특성 이해를 위한 MRR 및 PASIVEL 우적계의 관측사례 분석 (Analysis of Observational Cases Measured by MRR and PARSIVEL Disdrometer for Understanding the Physical Characteristics of Precipitation)

  • 차주완;장기호;오성남;최영진;정진임;정재원;양하영;배진영;강선영
    • 대기
    • /
    • 제20권1호
    • /
    • pp.37-47
    • /
    • 2010
  • The methods measuring the precipitation drop size distribution(hereafter referred to as DSD) at Cloud Physics Observation System (CPOS) in Daegwallyeong are to use PARSIVEL (PARticle SIze and VELocity) disdrometer (hereafter referred to as PARSIVEL) and Micro Rain Radar (hereafter referred to as MRR). First of all, PARSIVEL and MRR give good correlation coefficients between their rain rates and those of rain gage: $R^2=0.93$ and 0.91, respectively. For the DSD, the rain rates are classified in 3 categories (Category 1: rr (Rain Rate) ${\leq}0.5\;mm\;h^{-1}$, Category 2: $0.5\;mm\;h^-1$ < rr < $4.0\;mm\;h^{-1}$, Category 3: rr ${\geq}4\;mm\;h^{-1}$). The shapes of PARSIVEL and MRR DSD are relatively most similar in category 2. In addition, we retrieve the vertical rain rate and liquid water content from MRR under melting layer, calculated by Cha et al's method, in Daegwallyeong ($37^{\circ}41{\prime}N$, $128^{\circ}45^{\prime}E$, 843 m ASL, mountain area) and Haenam ($34^{\circ}33^{\prime}N$, $126^{\circ}34^{\prime}E$, 4.6 m ASL, coast area). The vertical variations of rain rate and liquid water content in Daegwallyeong are smaller than those in Haenam. We think that this different vertical rain rate characteristic for both sites is due to the vertical different cloud type (convective and stratiform cloud seem dominant at Haenam and Daegwallyeong, respectively). This suggests that the statistical precipitation DSD model, for the application of weather radar and numerical simulation of precipitation processes, be considered differently for the region, which will be performed in near future.

Rheology and pipeline transportation of dense fly ash-water slurry

  • Usui, Hiromoto;Li, Lei;Suzuki, Hiroshi
    • Korea-Australia Rheology Journal
    • /
    • 제13권1호
    • /
    • pp.47-54
    • /
    • 2001
  • Prediction of the maximum packing volume fraction with non-spherical particles has been one of the important problems in powder technology. The sphericity of fly ash particles depending on the particle diameter was measured by means of a CCD image processing instrument. An algorithm to predict the maximum packing volume fraction with non-spherical particles is proposed. The maximum packing volume fraction is used to predict the slurry viscosity under well dispersed conditions. For this purpose, Simha's cell model is applied for concentrated slurry with wide particle size distribution. Also, Usui's model developed for aggregative slurries is applied to predict the non-Newtonian viscosity of dense fly ash - water slurry. It is certified that the maximum packing volume fraction for non-spherical particles can be successfully used to predict slurry viscosity. The pressure drop in a pipe flow is predicted by using the non-Newtonian viscosity of dense fly ash-water slurry obtained by the present model. The predicted relationship between pressure drop and flow rate results in a good agreement with the experimented data obtained for a test rig with 50 mm inner diameter tube. Base on the design procedure proposed in this study, a feasibility study of fly ash hydraulic transportation system from a coal-fired power station to a controlled deposit site is carried out to give a future prospect of inexpensive fly ash transportation technology.

  • PDF

Methods of Improving Operational Reliability of Oil Well Casing

  • Sergey A. Dolgikh;Irek I. Mukhamatdinov
    • Corrosion Science and Technology
    • /
    • 제23권1호
    • /
    • pp.1-10
    • /
    • 2024
  • Oil well casing leak is caused by contact of casing outer surface with formation electrolyte. It is usually associated with an aquifer with a high salt content or absence of a cement ring behind the casing. The only way to reduce external casing corrosion is through cathodic protection. Through cathodic polarization of casing structure, electron content in crystal lattice and electron density will increase, leading to a potential shift towards the cathodic region. At Tatneft enterprises, cathodic protection is carried out according to cluster and individual schemes. The main criterion for cathodic protection is the size of protective current. For a casing, the protective current is considered sufficient if measurements with a two-contact probe show that the electric current directed to the casing has eliminated all anode sites. To determine the value of required protective current, all methods are considered in this work. In addition, an analysis of all methods used to determine the minimum protective current of the casing is provided. Results show that the method of measuring potential drop along casing is one of the most reliable methods for determining the value of protective current.

중년여성의 사이즈 스펙개발을 위한 인체치수 및 체형분석에 관한 연구 - 부산지역을 중심으로 - (Body Type Measurements and Analysis for the Development of Size Specifications of Middle Aged Women - Focused on Busan Regional Area -)

  • 심부자
    • 복식
    • /
    • 제52권2호
    • /
    • pp.59-70
    • /
    • 2002
  • For the purpose of providing basic data for the development of size specifications for middle-aged women in Busan, one dimensional measurements were made with the subjects. ranging 45 to 59 in age. The following are the conclusions : 1) According to ages, the middle and elder groups of the middle-aged women shared similar body types, having shorter height, more lowered bust. and increased upper-body depth and girth factors, compared with the earlier middle-aged women group. But the thigh girth of the elder middle-aged group (age: 55∼59) was the lowest, maybe owing to the aged lower-body muscles. 2) In the comparison with national averages. armhole girth, elbow girth, wrist girth. back waist length, side neck point-B.P.-waist line, and sleeve length showed great differences. This is problematic in that the national size standards fail to reflect each legion\`s peculiar body type characteristics. 3) Even though body types were classified according to drop value criteria suggested by KS specifications, 23.05% did not belong to the criteria. They were thus classified as A, N, and H body types, following the distribution of the present experiment. 4) In consideration of the economy factor of the production and sales of the clothes industry, the combinations of height and chest garth for the middle-aged Busan women were as follows: 155cm-85cm (Body Type A) 150cm-88cm (Body Type N), and 155cm-94cm (Body Type H).

관성 충돌 방식의 액적 분리장치의 수분제거효율 평가 (Evaluation of Removal Efficiency of Water Contents using Inertial Impaction Separator)

  • 이신영;홍원석;신완호;김규진;송동근
    • 한국입자에어로졸학회지
    • /
    • 제9권1호
    • /
    • pp.23-29
    • /
    • 2013
  • Inertial impaction type mist eliminators are the most effective instruments to separate mist from the gas. In this work, the effect of the horizontal chevron type mist eliminators is characterized experimentally. Droplet size distribution and evaluation of removal efficiency of the chevron type mist eliminators at different gas flows were investigated using an aerosol particle size analyzer and a portable aerosol spectrometer, respectively. The experimental investigations showed that the mist removal efficiency in these instruments is dependent in the droplet size, and the pressure drop is nil.

Factors Affecting Climate Change Accounting Disclosure Among Saudi Publicly List Firms on the Saudi Stock Exchange Market

  • Asaad Mubarak Hussien, MUSA;Abubkr Ahmed Elhadi, ABDELRAHEEM;Abbas Abdelrahman, ADAM
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제10권2호
    • /
    • pp.99-108
    • /
    • 2023
  • This study's goal is to investigate the effects of board size, the number of annual board meetings, the profitability of the company, and the audit Committee on the disclosure of climate change in Saudi companies listed on the stock exchange. It was conducted to evaluate affecting some factors on carbon emissions by the regression model. The study uses the content analysis method. Data was collected from the annual and sustainability reports, and the platform database Refinitiv, an LSEG (London Stock Exchange Group Company) for the period 2018 to 2021. The study sample is 51 companies. The study findings showed Saudi Arabia saw its first significant overall drop in CO2 emissions with a 22.61 MtCO2 decline (3.93%) in 2018. The study revealed a positive connection between the size of the director's board, and the disclosure of carbon emissions in Saudi firms listed on the stock market. While other factors are not related to the number of director's board meetings, the audit committee, and the profitability of the company on the disclosure of carbon emissions in the Saudi companies listed on the stock exchange.

황화수소 제거를 위한 Biofilter에 관한 연구 (A Study on Biofilter for Hydrogen Sulfide Removal)

  • 빈정인;이병헌;김중균;권성현;김상규;이민규
    • 한국환경과학회지
    • /
    • 제10권4호
    • /
    • pp.287-292
    • /
    • 2001
  • A packed bed of volcanic rock was used as deodorizing material to remove hydrogen sulfide($H_2$S) from air in a laboratory-scale column, and was inoculated with Thiobacillus sp. as $H_2S$ oxidizer. The effects of volcanic rock particle size distribution on system pressure drop were examined. Various tests have been conducted to evaluate the effect of $H_2S$ inlet concentration and CBCT(Empty Bed Contact Time) on $H_2S$ elimination. The pressure drop for particles of size range from 5.6 to 10 mm was 14 mm$H_2S$/m at a representative gas velocity of 0.25m/s. Biofilter using scoria and Thiobacillus sp. could get the stable removal efficiencies more than 99.9% under $H_2S$ inlet concentrations in the range from 30 to 1,100ppm at a constant gas flow rate of $15.2{\ell}$/min. $H_2S$ removal efficiencies greater than 99% were observed as long as EBCT was longer than 8sec at the 250ppm of $H_2S$ inlet concentration. When EBCT was reduced to 5.5 sec, $H_2S$ removal efficiency decreased by about 12 percent. The maximum $H_2S$ elimination capacity was determined to be 269g-$H_2S/m^3{\cdot}hr$.

  • PDF