• 제목/요약/키워드: Drop simulations

검색결과 194건 처리시간 0.022초

가스 조절용 레귤레이터의 유동 및 성능해석 (Analysis of Flow and Performance of Regulator for Clean Gas Supply System)

  • 김명관;이연수;최우진;권오붕;박정
    • 동력기계공학회지
    • /
    • 제13권1호
    • /
    • pp.13-18
    • /
    • 2009
  • In this study, flow characteristics at the regulators, which is very important for clean gas supply systems for semiconductors and LCD industries, are investigated. Numerical simulations are carried out to visualize flows at regulators for several flow rates and to investigate pressure losses at some parts in the regulator. Velocity field at the regulator along with the detailed velocity field near the spring and near the valve is shown. New regulator models are proposed in this paper, and numerical simulations are also carried out to visualize flows at regulator for several flow rates, and to investigate pressure losses at the parts in new models. Pressure drops a lot across the valve seat. Pressure drop increases as mass flow rate increases. Especially for small opening, pressure drop increases rapidly as mass flow rate becomes large.

  • PDF

IGBT 순방향 전압강하의 계산 (Calculation of Forward Voltage Drop of IGBTs)

  • 최병성;정상구
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권3호
    • /
    • pp.161-164
    • /
    • 2000
  • A simple methode for calculating the forward voltage drop of IGBTs is presented, on the voltage drops on the p+ body, the reverse biased depletion region between p+body and epi-layer, the epi layer, and the forward biased collector junction. The decrease of the total current density in the epi layer near the p+ body is taken into account. The proposed methode allows a simple but accurate determination of the forward voltage drop in IGBTs, avoiding the complex path taken in the previous model for the forward voltage drops on channel, accumulation region, and epi region. Numerical simulations for 1kV NPT-IGBT with a uniformly doped collector are shown to support the analytical results.

  • PDF

나선형 사각덕트 내의 압력강하 (Pressure Drop in a Helical Square Duct)

  • 유승엽;윤주현;이두정
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.398-403
    • /
    • 2001
  • Pressure drop at a helical square duct orifice is numerically evaluated. The orifice is installed at the entrance of a once-through steam generator tube to suppress flow instabilities. The calculated results are compared with the available experimental correlations, and showed good agreement. Effects of curvature ratio and characteristics of the secondary flow with Reynolds number are reported. Through the numerical simulations, pressure drop mechanisms were well understood inside the compact and complicated orifice geometry.

  • PDF

Impact Bending Test Simulations of FH32 High-strength Steel for Arctic Marine Structures

  • Choung, Joonmo;Han, Donghwa;Noh, Myung-Hyun;Lee, Jae-Yik;Shim, Sanghoon
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제2권1호
    • /
    • pp.28-39
    • /
    • 2016
  • This paper provides theoretical and experimental results to verify the crashworthiness of FH32 high-strength steel for arctic marine structures against ice impact. Assuming that side-shell structures of the Korean arctic research vessel, ARAON, with ice-notation PL10, collide with sheet ice, one-third-scale test specimens with a single transverse frame are manufactured. Impact-bending tests were conducted using a rigid steel striker that mimics sheet ice. Drop height was calculated by considering the speed at which sheet ice is rammed. Prior to impact-bending tests, tensile coupon tests were conducted at various temperatures. The impact-bending tests were carried out using test specimens fully fixed to the inside bottom frame of a cold chamber. The drop-weight velocity and test specimen deformation speed were measured using a high-speed camera and digital image correlation analysis (DICA). Numerical simulations were carried out under the same conditions as the impact-bending tests. The simulation results were in agreement with the test results, and strain rate was a key factor for the accuracy of numerical simulations.

Tip Clearance Effect on Through-Flow and Performance of a Centrifugal Compressor

  • Eum, Hark-Jin;Kang, Young-Seok;Kang, Shin-Hyoung
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.979-989
    • /
    • 2004
  • Numerical simulations have been performed to investigate tip clearance effect on through-flow and performance of a centrifugal compressor which has the same configuration of impeller with six different tip clearances. Secondary flow and loss distribution have been surveyed to understand the flow mechanism due to the tip clearance. Tip leakage flow strongly interacts with mainstream flow and considerably changes the secondary flow and the loss distribution inside the impeller passage. A method has been described to quantitatively estimate the tip clearance effect on the performance drop and the efficiency drop. The tip clearance has caused specific work reduction and additional entropy generation. The former, which is called inviscid loss, is independent of any internal loss and the latter, which is called viscous loss, is dependent on every loss in the flow passage. Two components equally affected the performance drop as the tip clearances were small, while the efficiency drop was influenced by the viscous component alone. The additional entropy generation was modeled with all the kinetic energy of the tip leakage flow. Therefore, the present paper can provide how to quantitatively estimate the tip clearance effect on the performance and efficiency.

유체-구조 연성해석 기반 해저케이블 위해인자의 수중낙하 특성 비교 (Comparison of Underwater Drop Characteristics for Hazard Apparatuses on Subsea Cable Using Fluid-Structure Interaction Analysis)

  • 장경호;김정훈;송창용
    • 한국해양공학회지
    • /
    • 제32권5호
    • /
    • pp.324-332
    • /
    • 2018
  • It is known that damages to the subsea cables used for electric power transmission between islands and countries, including renewable energy from offshore wind power, current, tides, etc., cost much to restore, which causes social and economic losses. Various types of fishing rigs and anchors have been reported to be the greatest hazards to subsea cables. It is possible to design and construct a suitable protection facility for a subsea cable by precisely estimating the underwater behavior of such hazardous apparatuses. In this study, numerical simulations of the underwater behaviors of various hazardous apparatuses were carried out using fluid-structure interaction (FSI) analysis as a basic study to simulate the actual behavior phenomena of hazardous apparatuses in relation to a subsea cable. In addition, the underwater drop characteristics according to the types of hazardous apparatuses were compared. In order to verify the accuracy of the FSI analysis method used in this study, we compared the test results for underwater drops of a steel ball bearing. Stock anchors, stockless anchors, and rocket piles, which were actually reported to be the cases of damage to subsea cables along the southwest coast of Korea, were considered as the hazardous apparatuses for the numerical simulations. Each hazardous apparatus was generated by a Lagrangian model and coupled with the fluid domain idealized by the Eulerian equation to construct the three-dimensional FSI analysis model. The accuracy of the numerical simulation results was verified by comparing them with the analytical solutions, and the underwater drop characteristics according to the types of hazard apparatuses were compared.

Scaling of ground motions from Vrancea (Romania) earthquakes

  • Pavel, Florin;Vacareanu, Radu
    • Earthquakes and Structures
    • /
    • 제11권3호
    • /
    • pp.505-516
    • /
    • 2016
  • This paper evaluates the scaling of ground motions recorded from nine intermediate-depth earthquakes produced in the Vrancea seismic zone in Romania. The considered ground motion database consists of 363 horizontal recordings obtained on soil classes B and C (according to Eurocode 8). An analysis of the inter- and intra-event spectral accelerations is performed in order to gain information regarding the magnitude and distance scaling of the Vrancea ground motions. The analyses reveal a significant influence of the earthquake magnitude and focal depth on the distance scaling and different magnitude and distance scaling for the two soil classes. A linear magnitude and distance scaling is inferred from the results for the range of magnitudes $5.2{\leq}M_W{\leq}7.1$. The results obtained are checked through stochastic simulations and the influence of the stress drop and kappa values on the ground motion levels is assessed. In addition, five ground motion models which were tested in other studies using recordings from Vrancea earthquakes are analyzed in order to evaluate their corresponding host stress drop and kappa. The results show generally a direct connection between the host kappa values and the host stress drop values. Moreover, all the ground motion models depict magnitude dependent host kappa and stress drop levels.

충격기류식 여과집진기의 내부 유동 시뮬레이션 해석을 통한 압력손실 예측 (Prediction of Pressure Drop Using the Internal Flow Simulation of Pulse Air Jet Bag Filters)

  • 장경민;정은상;서정민
    • 한국환경과학회지
    • /
    • 제29권5호
    • /
    • pp.457-468
    • /
    • 2020
  • With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20 ㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30%, thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.

변압기 여자돌입에 의한 전력품질 분석 (Analysis of Power Quality by Transformer Inrush Current)

  • 서훈철;여상민;김철환;유영식;조범섭
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.932-937
    • /
    • 2008
  • The transformer inrush current can cause a voltage drop by source impedance. This current can impact sensitive loads by the voltage drop. Therefore, it is necessary to take measures to limit this inrush current. This study, described in this paper, analyzes the power quality affected by transformer inrush current using the X power system in Korea. The Electromagnetic Transients Program(EMTP) is used to analyze the transient phenomenon. We discuss a method to model the hysteresis curve of the transformer in EMTP. We carried out various simulations to analyze the power quality during transformer energization. The analysis results of voltage drop by the inrush current occurrence when certain requirements are met are presented.

사이클론 방식 유분리기의 출구 튜브 설계 (Design of the Outlet-Port Tube of a Cyclone-Type Oil Separator for a Compressor)

  • 장성일;안준
    • 설비공학논문집
    • /
    • 제27권8호
    • /
    • pp.402-408
    • /
    • 2015
  • A series of numerical simulations have been carried out to study the performances of cyclone-type oil separators, which are designed for refrigeration-system compressors. The corresponding working fluid is R22, which is a typical refrigerant, whereby a mineral-oil droplet is supplied (Ed-highlight-My interpretation). The outlet-tube length in relation to the total chamber volume is considered a design parameter. Depending on the tube length, the separation efficiency varies from 98.7% to 99.3%, while the predicted pressure drop is between 5.1 kPa and 6.4 kPa. Considering both the pressure drop and separation efficiency, the length of the outlet-port tube of the separator is 152 mm.