• 제목/요약/키워드: Drop analysis

검색결과 1,883건 처리시간 0.036초

Numerical estimation of errors in drop angle during drop tests of IP-Type metallic transport containers for radioactive materials

  • Lim, Jongmin;Yang, Yun Young;Lee, Ju-chan
    • Nuclear Engineering and Technology
    • /
    • 제53권6호
    • /
    • pp.1878-1886
    • /
    • 2021
  • For industrial package (IP)-type transport containers for radioactive materials, a free drop test should be conducted under regulatory conditions. Owing to various uncertainties observed during the drop test, errors in drop angles inevitably occur. In IP-type metal transport containers in which the container directly impacts onto a rigid target without any shock absorbing materials, the error in the drop angle due to a slight misalignment makes a significant difference from the ideal drop. In particular, in a vertical drop, the error in the drop angle causes a strong secondary impact. In this paper, a numerical method is proposed to estimate the error in the drop angle occurring during the test. To determine this error, an optimization method accompanying a computational drop analysis is proposed, and a surrogate model is introduced to ensure calculation efficiency. Effectiveness of the proposed method is validated by performing the verification and comparison between the test and the analysis applied with the drop angle error.

Challenging a Single-Factor Analysis of Case Drop in Korean

  • Chung, Eun Seon
    • 한국언어정보학회지:언어와정보
    • /
    • 제19권1호
    • /
    • pp.1-18
    • /
    • 2015
  • Korean marks case for subjects and objects, but it is well known that case-markers can be dropped in certain contexts. Kwon and Zribi-Hertz (2008) establishes the phenomenon of Korean case drop on a single factor of f(ocus)-structure visibility and claims that both subject and object case drop can fall under a single linguistic generalization of information structure. However, the supporting data is not empirically substantiated and the tenability of the f-structure analysis is still under question. In this paper, an experiment was conducted to show that the specific claims of Kwon and Zribi-Hertz's analysis that places exclusive importance on information structure cannot be adequately supported by empirical evidence. In addition, the present study examines H. Lee's (2006a, 2006c) multi-factor analysis of object case drop and investigates whether this approach can subsume both subject and object case drop under a unified analysis. The present findings indicate that the multi-factor analysis that involves the interaction of independent factors (Focus, Animacy, and Definiteness) is also compatible with subject case drop, and that judgments on case drop are not categorical but form gradient statistical preferences.

  • PDF

해양플랜트용 고압.고차압 제어밸브의 구조 안전성 평가 (Safety Estimation of High Pressure Drop Control Valve for Offshore Structures)

  • 김재웅
    • 한국생산제조학회지
    • /
    • 제20권5호
    • /
    • pp.553-558
    • /
    • 2011
  • This study have goal with conceptual design for offshore structures of high pressure drop control valve for localization valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25. In order to localize the Offshore structures high pressure drop control valve. This study is numerical analysis for zambil offshore project of high pressure drop control valve. The solver which ANSYS workbench used for offshore structures analysis. The working fluids assumed the glycerin(C3H8O3). The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and disk structure. In this study a multi-disk of high pressure drop control valve is designed and manufactured. Then, the flow rate and high pressure dorp of fluids flowing in the high pressure drop control valve is CAE. So, this system can be easily substituted for the existing zambil offshore project system. Finally, safety estimation for trim design of high pressure drop control valve for offshore structures.

해운산업 기초인력의 이탈 원인에 관한 실증 연구 (The Breaking away Factors Analysis of the Preliminary Basic Seamen)

  • 이학헌
    • 한국항해학회지
    • /
    • 제22권3호
    • /
    • pp.73-92
    • /
    • 1998
  • Today the number of high school drop-outs is increasing , and also it is serious social problems. But almost factor analyses on the drop-outs are projected by questionnaire. This paper find out by the real data form the concerned documents what factors of drop-outs are. In order to accomplish this study purpose, the methodology are used such as Fequency Analysis, Correlation Analysis, Crosstabulation Analysis. Through the this study this paper could siome suggestions as followings. The first , all education authority should analysis what factors of drop-outs and what drop-out situation is . The second, every teacher should counsel with all problem students sincerely regarding to their characters, future occupations, life course and etc. The third, the most and worst important factors of drop-out is runaway. Because it is very difficult for teacher to teach, lead and guide a runaway student, therefore thepreventino of runaway is efficient for reducing of drop-outs. The fouth, the students violating rules are retrained propoerly in view of guide for good path. The fifth, besides of the above factors. there are drop-out factors such as the health, disease, dafety accidents . All parents. teachers, and students should try their best to solve. To the end, education authority try to encourage teachers to do their role with maximum sense of duty.

  • PDF

DROP IMPACT ANALYSIS OF PLATE-TYPE FUEL ASSEMBLY IN RESEARCH REACTOR

  • Kim, Hyun-Jung;Yim, Jeong-Sik;Lee, Byung-Ho;Oh, Jae-Yong;Tahk, Young-Wook
    • Nuclear Engineering and Technology
    • /
    • 제46권4호
    • /
    • pp.529-540
    • /
    • 2014
  • In this research, a drop impact analysis of a fuel assembly in a research reactor is carried out to determine whether the fuel plate integrity is maintained in a drop accident. A fuel assembly drop accident is classified based on where the accident occurs, i.e., inside or outside the reactor, since each occasion results in a different impact load on the fuel assembly. An analysis procedure suitable for each drop situation is systematically established. For an accident occurring outside the reactor, the direct impact of a fuel assembly on the pool bottom is analyzed using implicit and explicit approaches. The effects of the key parameters, such as the impact velocity and structural damping ratios, are also studied. For an accident occurring inside the reactor, the falling fuel assembly may first hit the fixing bar at the upper part of the standing fuel assembly. To confirm the fuel plate integrity, a fracture of the fixing bar should be investigated, since the fixing bar plays a role in protecting the fuel plate from the external impact force. Through such an analysis, the suitability of an impact analysis procedure associated with the drop situation in the research reactor is shown.

선박용 스트레이너의 압력강하 예측에 관한 연구 (A Study on the Prediction of Pressure Drop for Ship Strainer)

  • 손인수
    • 한국산업융합학회 논문집
    • /
    • 제24권5호
    • /
    • pp.573-579
    • /
    • 2021
  • In this study, flow analysis was performed on three types of strainers for ships with different flow rates to predict the pressure drop of the strainer due to the filter of strainer. In the case of flow analysis, the flow analysis was performed by applying the porous media method by applying the resistance value derived by Ergun's equation to the filter position. As a result of the analysis, it was found that when the dimensions of the strainer body were small, the influence of the flow rate on the pressure drop was large. In addition, the amount of pressure drop and the flow rate are almost linearly proportional, and an analysis formula that can predict the amount of pressure drop was derived. In order to predict the amount of pressure drop of the strainer when blockage exist in the strainer filter, the analysis was performed by introducing the resistance ratio to derive the prediction equation. Using this equation, it is thought that it will be possible to predict the performance of the strainer due to blockage in the future strainer design and field application.

2 Drop 구조를 가지는 Differential Pair의 Impedance 해석 및 설계 방안 (Optimized Design Technique of a Differential Pair Having 2 Drop Configuration through Impedance Analysis)

  • 배민지;김윤정;최웅;양국보;김영수
    • 한국전자파학회논문지
    • /
    • 제20권2호
    • /
    • pp.193-199
    • /
    • 2009
  • 본 논문에서는 microstrip line 구조를 가지는 differential pair의 2 drop 구조에 대한 임피던스 해석을 reflection theory를 바탕으로 분석하였다. 또한 시뮬레이션을 통한 transient 해석을 통해 임피던스 해석의 타당성을 검증하였다. 위와 같은 해석 과정을 통하여 다양한 drop 구조의 신호 전달 특성을 이해할 수 있다. 임피던스 해석을 바탕으로 2 drop 구조 해석을 통하여 최적의 signal integrity를 가지는 설계 기법을 제안하였고, circuit 시뮬레이션 해석(Ansoft designer)을 통해 signal integrity 효과를 검증하였다.

사용후 핵연료 수송용기의 수평낙하충격에 관한 연구 (A Study on the Side Drop Impact of a Nuclear Spent Fuel Shipping Cask)

  • 정성환;이영신
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.457-469
    • /
    • 1997
  • A nuclear spent fuel shipping cask is required by IAEA and domestic regulations to withstand a 9m free drop condition. In this paper, the structural analysis under the 9m side drop condition was performed to understand the dynamic impact behavior and to evaluate the safety of the cask for 7 PWR nuclear spent fuel assemblies. The analysis result was compared with the measured value of the 9m side drop test for the 1/3 scaled-down model and the accuracy of the 3D analysis was confirmed. Analysis in accordance with the diameter of impact limiters for the proto-type cask were performed. Through the analysis, the impact behaviors due to the side drop and the effects dependent on the diameter of impact limiters were grasped. Maximum stress intensities on each part of the cask were respectively calculated by using the stress evaluation program and the structural safety of the cask was finally evaluated in accordance with the regulations.

해양플랜트용 고차압 제어밸브의 해석 및 설계 (CAE/CFD Analysis and Design of High-Pressure Drop Control Valve for Offshore Project)

  • 장성철;박태수;허남수;김인환
    • 한국기계가공학회지
    • /
    • 제14권5호
    • /
    • pp.42-49
    • /
    • 2015
  • In this study, the multi-disk of a high-pressure drop control valve is designed and manufactured. Then, the flow rate and high-pressure drop of fluids flowing in the high-pressure drop control valve is CAE/CFD. This study involves numerical analysis for the Zambil offshore project of a high-pressure drop control valve. ANSYS used a solver for offshore structures analysis. A high-pressure drop control valve, which transforms the power transfer of a system by reducing the inlet pressure of 345bar to the outlet pressure of 112bar, is a fundamental component in the offshore process. This study not only analyzes the relation between pressure drop and fluid velocity in a trim by using fluid analysis, but also examines the possibility of cavitation in a valve in addition to the plot for the extension of lifespan. It is demonstrated that the pressure drop from 345bar to 112bar is more feasible in the presence of the trim, which can induce a continuous and diminutive pressure drop in order to prevent cavitation in a high-pressure drop control valve.

펄스 GMA용접에서 용융 액적의 동특성 및 펄스 조건에 관한 해석 (Analysis of Dynamic Characteristics of Molten Drop and Pulse Condition in Pulsed-GMAW)

  • 최상균;강세령;이상룡
    • Journal of Welding and Joining
    • /
    • 제20권4호
    • /
    • pp.491-497
    • /
    • 2002
  • Dynamic behavior of the molten drop during the peak period in the pulsed-GMAW is simulated in this work using the VOF(volume of the fluid) algerian. The dynamic characteristics of molten drop such as minimum radius, average velocity and displacement of mass center were computed as well as the internal pressure and velocity. The minimum and maximum peak durations for detaching a drop were calculated.. The result of Analysis reveals that peak current and volume of pendant drop are important factors which affecting drop detachment. A simplified model of constant acceleration is proposed to describe the behavior of molten drop during peak current, and its results agree with the experimental results.